<
From version < 78.1 >
edited by Xiaoling
on 2022/06/10 09:38
To version < 77.86 >
edited by Xiaoling
on 2022/06/10 09:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -76,8 +76,6 @@
76 76  )))
77 77  
78 78  (((
79 -
80 -
81 81  **Interface for Model: LT22222-L:**
82 82  )))
83 83  
... ... @@ -101,8 +101,6 @@
101 101  )))
102 102  
103 103  (((
104 -
105 -
106 106  **LoRa Spec:**
107 107  )))
108 108  
... ... @@ -162,10 +162,10 @@
162 162  )))
163 163  * (((
164 164  Packet engine up to 256 bytes with CRC.
161 +
162 +
165 165  )))
166 166  
167 -
168 -
169 169  == 1.3 Features ==
170 170  
171 171  * LoRaWAN Class A & Class C protocol
... ... @@ -176,8 +176,6 @@
176 176  * Firmware upgradable via program port
177 177  * Counting
178 178  
179 -
180 -
181 181  == 1.4  Applications ==
182 182  
183 183  * Smart Buildings & Home Automation
... ... @@ -187,8 +187,6 @@
187 187  * Smart Cities
188 188  * Smart Factory
189 189  
190 -
191 -
192 192  == 1.5 Hardware Variants ==
193 193  
194 194  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -202,8 +202,6 @@
202 202  * 1 x Counting Port
203 203  )))
204 204  
205 -
206 -
207 207  = 2. Power ON Device =
208 208  
209 209  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -226,9 +226,12 @@
226 226  
227 227  (((
228 228  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 +
220 +
229 229  )))
230 230  
231 231  
224 +
232 232  == 3.2 Example to join LoRaWAN network ==
233 233  
234 234  (((
... ... @@ -237,13 +237,12 @@
237 237  
238 238  [[image:image-20220523172350-1.png||height="266" width="864"]]
239 239  
240 -
241 241  (((
242 242  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
243 243  )))
244 244  
245 245  (((
246 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
247 247  )))
248 248  
249 249  (((
... ... @@ -252,7 +252,6 @@
252 252  
253 253  [[image:1653297924498-393.png]]
254 254  
255 -
256 256  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
257 257  
258 258  Add APP EUI in the application.
... ... @@ -266,7 +266,7 @@
266 266  
267 267  
268 268  (((
269 -(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
270 270  )))
271 271  
272 272  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -284,7 +284,6 @@
284 284  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 285  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
286 286  
287 -
288 288  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
289 289  
290 290  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -292,8 +292,6 @@
292 292  [[image:image-20220523174024-3.png]]
293 293  
294 294  (((
295 -
296 -
297 297  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
298 298  )))
299 299  
... ... @@ -307,7 +307,6 @@
307 307  
308 308  For example if payload is: [[image:image-20220523175847-2.png]]
309 309  
310 -
311 311  **The value for the interface is:  **
312 312  
313 313  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -339,6 +339,7 @@
339 339  ** DO1 LED is off in both case
340 340  
341 341  
329 +
342 342  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
343 343  
344 344  
... ... @@ -631,11 +631,13 @@
631 631  * **AT+MOD=1 ** **~-~->** The normal working mode
632 632  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
633 633  
622 +
634 634  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
635 635  
636 636  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
637 637  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
638 638  
628 +
639 639  **AT Command to set Trigger Condition**:
640 640  
641 641  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -649,7 +649,6 @@
649 649  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
650 650  
651 651  
652 -
653 653  (% style="color:#4f81bd" %)**Trigger base on current**:
654 654  
655 655  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -659,7 +659,6 @@
659 659  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
660 660  
661 661  
662 -
663 663  (% style="color:#4f81bd" %)**Trigger base on DI status**:
664 664  
665 665  DI status trigger Flag.
... ... @@ -666,13 +666,12 @@
666 666  
667 667  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
668 668  
669 -
670 670  **Example:**
671 671  
672 672  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
673 673  
674 674  
675 -**Downlink Command to set Trigger Condition:**
662 +**Downlink Command to set Trigger Condition**
676 676  
677 677  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
678 678  
... ... @@ -701,7 +701,6 @@
701 701  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
702 702  
703 703  
704 -
705 705  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
706 706  
707 707  MOD6 Payload : total 11 bytes payload
... ... @@ -715,6 +715,7 @@
715 715  
716 716  * Each bits shows if the corresponding trigger has been configured.
717 717  
704 +
718 718  **Example:**
719 719  
720 720  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -726,6 +726,7 @@
726 726  
727 727  * Each bits shows which status has been trigger on this uplink.
728 728  
716 +
729 729  **Example:**
730 730  
731 731  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -737,6 +737,7 @@
737 737  
738 738  * Each bits shows which status has been trigger on this uplink.
739 739  
728 +
740 740  **Example:**
741 741  
742 742  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -778,6 +778,8 @@
778 778  
779 779  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
780 780  
770 +
771 +
781 781  === 3.4.1 Common Commands ===
782 782  
783 783  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0