Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,8 +76,6 @@ 76 76 ))) 77 77 78 78 ((( 79 - 80 - 81 81 **Interface for Model: LT22222-L:** 82 82 ))) 83 83 ... ... @@ -101,8 +101,6 @@ 101 101 ))) 102 102 103 103 ((( 104 - 105 - 106 106 **LoRa Spec:** 107 107 ))) 108 108 ... ... @@ -162,10 +162,10 @@ 162 162 ))) 163 163 * ((( 164 164 Packet engine up to 256 bytes with CRC. 161 + 162 + 165 165 ))) 166 166 167 - 168 - 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -176,8 +176,6 @@ 176 176 * Firmware upgradable via program port 177 177 * Counting 178 178 179 - 180 - 181 181 == 1.4 Applications == 182 182 183 183 * Smart Buildings & Home Automation ... ... @@ -187,8 +187,6 @@ 187 187 * Smart Cities 188 188 * Smart Factory 189 189 190 - 191 - 192 192 == 1.5 Hardware Variants == 193 193 194 194 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -285,6 +285,7 @@ 285 285 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 286 286 287 287 280 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -323,6 +323,7 @@ 323 323 * [1] RO1 relay channel is close and the RO1 LED is ON. 324 324 * [0] RO2 relay channel is open and RO2 LED is OFF; 325 325 319 + 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -339,6 +339,7 @@ 339 339 ** DO1 LED is off in both case 340 340 341 341 336 + 342 342 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 343 343 344 344 ... ... @@ -636,6 +636,7 @@ 636 636 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 637 637 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 638 638 634 + 639 639 **AT Command to set Trigger Condition**: 640 640 641 641 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -715,6 +715,7 @@ 715 715 716 716 * Each bits shows if the corresponding trigger has been configured. 717 717 714 + 718 718 **Example:** 719 719 720 720 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -726,6 +726,7 @@ 726 726 727 727 * Each bits shows which status has been trigger on this uplink. 728 728 726 + 729 729 **Example:** 730 730 731 731 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -737,6 +737,7 @@ 737 737 738 738 * Each bits shows which status has been trigger on this uplink. 739 739 738 + 740 740 **Example:** 741 741 742 742 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -778,6 +778,7 @@ 778 778 779 779 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 780 780 780 + 781 781 === 3.4.1 Common Commands === 782 782 783 783 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]