From version < 77.99 >
edited by Xiaoling
on 2022/06/10 09:32
To version < 77.93 >
edited by Xiaoling
on 2022/06/10 09:31
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -276,7 +276,6 @@
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 278  
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -315,8 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -333,7 +333,6 @@
333 333  ** DO1 LED is off in both case
334 334  
335 335  
336 -
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 339  
... ... @@ -626,14 +626,11 @@
626 626  * **AT+MOD=1 ** **~-~->** The normal working mode
627 627  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
628 628  
629 -
630 630  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
631 631  
632 632  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
633 633  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
634 634  
635 -
636 -
637 637  **AT Command to set Trigger Condition**:
638 638  
639 639  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -647,7 +647,6 @@
647 647  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
648 648  
649 649  
650 -
651 651  (% style="color:#4f81bd" %)**Trigger base on current**:
652 652  
653 653  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -657,7 +657,6 @@
657 657  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
658 658  
659 659  
660 -
661 661  (% style="color:#4f81bd" %)**Trigger base on DI status**:
662 662  
663 663  DI status trigger Flag.
... ... @@ -670,7 +670,7 @@
670 670  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 672  
673 -**Downlink Command to set Trigger Condition:**
664 +**Downlink Command to set Trigger Condition**
674 674  
675 675  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
676 676  
... ... @@ -694,12 +694,12 @@
694 694  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
695 695  
696 696  
688 +
697 697  **Example2**: AA 02 01 00
698 698  
699 699  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
700 700  
701 701  
702 -
703 703  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
704 704  
705 705  MOD6 Payload : total 11 bytes payload
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0