... ... @@ -275,8 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -284,8 +284,6 @@
284 284  [[image:image-20220523174024-3.png]]
285 285  
286 286  (((
287 -
288 -
289 289  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
290 290  )))
291 291  
... ... @@ -299,7 +299,6 @@
299 299  
300 300  For example if payload is: [[image:image-20220523175847-2.png]]
301 301  
302 -
303 303  **The value for the interface is:  **
304 304  
305 305  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -315,8 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 -
320 320  **LT22222-L:**
321 321  
322 322  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,11 +332,8 @@
332 332  ** DO1 is high in case there is load between DO1 and V+.
333 333  ** DO1 LED is off in both case
334 334  
335 -
336 -
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 -
340 340  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
341 341  
342 342  (((
... ... @@ -345,7 +345,6 @@
345 345  
346 346  [[image:image-20220523180452-3.png]]
347 347  
348 -
349 349  (((
350 350  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
351 351  )))
... ... @@ -361,8 +361,6 @@
361 361  )))
362 362  
363 363  (((
364 -
365 -
366 366  **To use counting mode, please run:**
367 367  )))
368 368  
... ... @@ -381,8 +381,6 @@
381 381  )))
382 382  
383 383  (((
384 -
385 -
386 386  (% style="color:#4f81bd" %)**AT Commands for counting:**
387 387  )))
388 388  
... ... @@ -479,9 +479,9 @@
479 479  )))
480 480  
481 481  
467 +
482 482  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
483 483  
484 -
485 485  **LT22222-L**: This mode the DI1 is used as a counting pin.
486 486  
487 487  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -488,7 +488,6 @@
488 488  
489 489  [[image:image-20220523181903-8.png]]
490 490  
491 -
492 492  (((
493 493  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
494 494  )))
... ... @@ -504,8 +504,6 @@
504 504  )))
505 505  
506 506  (((
507 -
508 -
509 509  **To use this mode, please run:**
510 510  )))
511 511  
... ... @@ -532,8 +532,6 @@
532 532  )))
533 533  
534 534  (((
535 -
536 -
537 537  **Plus below command for AVI1 Counting:**
538 538  )))
539 539  
... ... @@ -569,14 +569,11 @@
569 569  
570 570  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
571 571  
572 -
573 573  **LT22222-L**: This mode the DI1 is used as a counting pin.
574 574  
575 575  [[image:image-20220523182334-9.png]]
576 576  
577 577  (((
578 -
579 -
580 580  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
581 581  )))
582 582  
... ... @@ -591,8 +591,6 @@
591 591  )))
592 592  
593 593  (((
594 -
595 -
596 596  **To use this mode, please run:**
597 597  )))
598 598  
... ... @@ -618,7 +618,6 @@
618 618  
619 619  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
620 620  
621 -
622 622  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
623 623  
624 624  For example, if user has configured below commands:
... ... @@ -633,7 +633,6 @@
633 633  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
634 634  
635 635  
636 -
637 637  **AT Command to set Trigger Condition**:
638 638  
639 639  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -647,7 +647,6 @@
647 647  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
648 648  
649 649  
650 -
651 651  (% style="color:#4f81bd" %)**Trigger base on current**:
652 652  
653 653  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -657,7 +657,6 @@
657 657  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
658 658  
659 659  
660 -
661 661  (% style="color:#4f81bd" %)**Trigger base on DI status**:
662 662  
663 663  DI status trigger Flag.
... ... @@ -664,13 +664,12 @@
664 664  
665 665  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
666 666  
667 -
668 668  **Example:**
669 669  
670 670  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
671 671  
672 672  
673 -**Downlink Command to set Trigger Condition:**
643 +**Downlink Command to set Trigger Condition**
674 674  
675 675  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
676 676  
... ... @@ -699,7 +699,6 @@
699 699  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
700 700  
701 701  
702 -
703 703  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
704 704  
705 705  MOD6 Payload : total 11 bytes payload
... ... @@ -714,7 +714,6 @@
714 714  * Each bits shows if the corresponding trigger has been configured.
715 715  
716 716  
717 -
718 718  **Example:**
719 719  
720 720  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -727,7 +727,6 @@
727 727  * Each bits shows which status has been trigger on this uplink.
728 728  
729 729  
730 -
731 731  **Example:**
732 732  
733 733  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -740,7 +740,6 @@
740 740  * Each bits shows which status has been trigger on this uplink.
741 741  
742 742  
743 -
744 744  **Example:**
745 745  
746 746  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -761,8 +761,6 @@
761 761  === 3.3.7 Payload Decoder ===
762 762  
763 763  (((
764 -
765 -
766 766  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
767 767  
768 768  