275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -283,8 +283,6 @@
283 283  [[image:image-20220523174024-3.png]]
284 284  
285 285  (((
286 -
287 -
288 288  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
289 289  )))
290 290  
... ... @@ -298,7 +298,6 @@
298 298  
299 299  For example if payload is: [[image:image-20220523175847-2.png]]
300 300  
301 -
302 302  **The value for the interface is:  **
303 303  
304 304  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -315,7 +315,6 @@
315 315  * [0] RO2 relay channel is open and RO2 LED is OFF;
316 316  
317 317  
318 -
319 319  **LT22222-L:**
320 320  
321 321  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,7 +332,6 @@
332 332  ** DO1 LED is off in both case
333 333  
334 334  
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -625,14 +625,11 @@
625 625  * **AT+MOD=1 ** **~-~->** The normal working mode
626 626  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
627 627  
628 -
629 629  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
630 630  
631 631  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
632 632  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
633 633  
634 -
635 -
636 636  **AT Command to set Trigger Condition**:
637 637  
638 638  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -646,7 +646,6 @@
646 646  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
647 647  
648 648  
649 -
650 650  (% style="color:#4f81bd" %)**Trigger base on current**:
651 651  
652 652  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -656,7 +656,6 @@
656 656  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
657 657  
658 658  
659 -
660 660  (% style="color:#4f81bd" %)**Trigger base on DI status**:
661 661  
662 662  DI status trigger Flag.
... ... @@ -663,13 +663,12 @@
663 663  
664 664  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
665 665  
666 -
667 667  **Example:**
668 668  
669 669  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
670 670  
671 671  
672 -**Downlink Command to set Trigger Condition:**
660 +**Downlink Command to set Trigger Condition**
673 673  
674 674  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
675 675  
... ... @@ -698,7 +698,6 @@
698 698  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
699 699  
700 700  
701 -
702 702  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
703 703  
704 704  MOD6 Payload : total 11 bytes payload
... ... @@ -712,8 +712,6 @@
712 712  
713 713  * Each bits shows if the corresponding trigger has been configured.
714 714  
715 -
716 -
717 717  **Example:**
718 718  
719 719  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -725,8 +725,6 @@
725 725  
726 726  * Each bits shows which status has been trigger on this uplink.
727 727  
728 -
729 -
730 730  **Example:**
731 731  
732 732  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -738,8 +738,6 @@
738 738  
739 739  * Each bits shows which status has been trigger on this uplink.
740 740  
741 -
742 -
743 743  **Example:**
744 744  
745 745  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -782,7 +782,6 @@
782 782  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
783 783  
784 784  
785 -
786 786  === 3.4.1 Common Commands ===
787 787  
788 788  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]