Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,7 +275,6 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 - 279 279 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 280 280 281 281 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -283,8 +283,6 @@ 283 283 [[image:image-20220523174024-3.png]] 284 284 285 285 ((( 286 - 287 - 288 288 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 289 289 ))) 290 290 ... ... @@ -298,7 +298,6 @@ 298 298 299 299 For example if payload is: [[image:image-20220523175847-2.png]] 300 300 301 - 302 302 **The value for the interface is: ** 303 303 304 304 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -315,7 +315,6 @@ 315 315 * [0] RO2 relay channel is open and RO2 LED is OFF; 316 316 317 317 318 - 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -332,7 +332,6 @@ 332 332 ** DO1 LED is off in both case 333 333 334 334 335 - 336 336 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 337 337 338 338 ... ... @@ -625,14 +625,11 @@ 625 625 * **AT+MOD=1 ** **~-~->** The normal working mode 626 626 * **AT+ADDMOD6=1** **~-~->** Enable trigger 627 627 628 - 629 629 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 630 630 631 631 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 632 632 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 633 633 634 - 635 - 636 636 **AT Command to set Trigger Condition**: 637 637 638 638 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -646,7 +646,6 @@ 646 646 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 647 647 648 648 649 - 650 650 (% style="color:#4f81bd" %)**Trigger base on current**: 651 651 652 652 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -656,7 +656,6 @@ 656 656 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 657 657 658 658 659 - 660 660 (% style="color:#4f81bd" %)**Trigger base on DI status**: 661 661 662 662 DI status trigger Flag. ... ... @@ -663,13 +663,12 @@ 663 663 664 664 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 665 665 666 - 667 667 **Example:** 668 668 669 669 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 670 670 671 671 672 -**Downlink Command to set Trigger Condition :**660 +**Downlink Command to set Trigger Condition** 673 673 674 674 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 675 675 ... ... @@ -698,7 +698,6 @@ 698 698 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 699 699 700 700 701 - 702 702 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 703 703 704 704 MOD6 Payload : total 11 bytes payload ... ... @@ -712,8 +712,6 @@ 712 712 713 713 * Each bits shows if the corresponding trigger has been configured. 714 714 715 - 716 - 717 717 **Example:** 718 718 719 719 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -725,8 +725,6 @@ 725 725 726 726 * Each bits shows which status has been trigger on this uplink. 727 727 728 - 729 - 730 730 **Example:** 731 731 732 732 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -738,8 +738,6 @@ 738 738 739 739 * Each bits shows which status has been trigger on this uplink. 740 740 741 - 742 - 743 743 **Example:** 744 744 745 745 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -782,7 +782,6 @@ 782 782 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 783 783 784 784 785 - 786 786 === 3.4.1 Common Commands === 787 787 788 788 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]