... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -16,9 +16,12 @@ 16 16 17 17 = 1.Introduction = 18 18 18 + 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -35,11 +35,13 @@ 35 35 ))) 36 36 37 37 ((( 38 -1) If user ’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.40 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 39 39 ))) 40 40 41 41 ((( 42 42 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 45 + 46 + 43 43 ))) 44 44 45 45 ((( ... ... @@ -48,12 +48,13 @@ 48 48 49 49 ))) 50 50 55 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( 54 54 55 55 56 -**Hardware System:** 61 +(% style="color:#037691" %)**Hardware System:** 57 57 ))) 58 58 59 59 * ((( ... ... @@ -76,7 +76,9 @@ 76 76 ))) 77 77 78 78 ((( 79 -**Interface for Model: LT22222-L:** 84 + 85 + 86 +(% style="color:#037691" %)**Interface for Model: LT22222-L:** 80 80 ))) 81 81 82 82 * ((( ... ... @@ -99,7 +99,9 @@ 99 99 ))) 100 100 101 101 ((( 102 -**LoRa Spec:** 109 + 110 + 111 +(% style="color:#037691" %)**LoRa Spec:** 103 103 ))) 104 104 105 105 * ((( ... ... @@ -159,21 +159,28 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 171 + 172 + 162 162 163 163 ))) 164 164 165 165 == 1.3 Features == 166 166 178 + 167 167 * LoRaWAN Class A & Class C protocol 168 168 * Optional Customized LoRa Protocol 169 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 181 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 170 170 * AT Commands to change parameters 171 171 * Remote configure parameters via LoRa Downlink 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 187 + 188 + 189 + 175 175 == 1.4 Applications == 176 176 192 + 177 177 * Smart Buildings & Home Automation 178 178 * Logistics and Supply Chain Management 179 179 * Smart Metering ... ... @@ -181,8 +181,12 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 200 + 201 + 202 + 184 184 == 1.5 Hardware Variants == 185 185 205 + 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) 187 187 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 188 188 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -194,12 +194,18 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 217 + 218 + 219 + 197 197 = 2. Power ON Device = 198 198 222 + 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 200 200 201 201 ((( 202 202 PWR will on when device is properly powered. 227 + 228 + 203 203 ))) 204 204 205 205 [[image:1653297104069-180.png]] ... ... @@ -208,16 +208,16 @@ 208 208 209 209 = 3. Operation Mode = 210 210 237 + 211 211 == 3.1 How it works? == 212 212 240 + 213 213 ((( 214 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.242 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 215 215 ))) 216 216 217 217 ((( 218 -In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 246 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 221 221 ))) 222 222 223 223 ... ... @@ -224,18 +224,24 @@ 224 224 225 225 == 3.2 Example to join LoRaWAN network == 226 226 253 + 227 227 ((( 228 228 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 256 + 257 + 229 229 ))) 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 262 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 265 + 266 + 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 270 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 279 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -256,8 +256,9 @@ 256 256 [[image:1653298023685-319.png]] 257 257 258 258 292 + 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 294 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -266,18 +266,22 @@ 266 266 267 267 == 3.3 Uplink Payload == 268 268 303 + 269 269 There are five working modes + one interrupt mode on LT for different type application: 270 270 271 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 272 -* **MOD2**: Double DI Counting + DO + RO 273 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 274 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 275 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 306 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 307 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 308 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 309 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 310 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 311 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 278 314 + 315 + 279 279 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 280 280 318 + 281 281 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 282 282 283 283 [[image:image-20220523174024-3.png]] ... ... @@ -294,8 +294,10 @@ 294 294 * DI is for digital input. DIx=1: high or float, DIx=0: low. 295 295 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 296 296 297 -(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 298 298 336 + 337 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L** 338 + 299 299 For example if payload is: [[image:image-20220523175847-2.png]] 300 300 301 301 ... ... @@ -332,6 +332,9 @@ 332 332 ** DO1 LED is off in both case 333 333 334 334 375 + 376 + 377 + 335 335 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 336 336 337 337 ... ... @@ -355,7 +355,7 @@ 355 355 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 356 356 357 357 ((( 358 -(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 401 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.** 359 359 ))) 360 360 361 361 ((( ... ... @@ -368,12 +368,7 @@ 368 368 ((( 369 369 ((( 370 370 **AT+MOD=2** 371 -))) 372 -))) 373 373 374 -(% class="box infomessage" %) 375 -((( 376 -((( 377 377 **ATZ** 378 378 ))) 379 379 ))) ... ... @@ -382,63 +382,39 @@ 382 382 383 383 384 384 (% style="color:#4f81bd" %)**AT Commands for counting:** 423 + 424 + 385 385 ))) 386 386 387 387 ((( 388 388 **For LT22222-L:** 389 -))) 390 390 391 -(% class="box infomessage" %) 392 -((( 393 -((( 394 -**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 395 -))) 396 -))) 397 397 398 -(% class="box infomessage" %) 399 -((( 400 -((( 401 -**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 402 -))) 403 -))) 431 +(% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger on low level, valid signal is 100ms) ** 404 404 405 -(% class="box infomessage" %) 406 -((( 407 -((( 408 -**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 409 -))) 410 -))) 433 +(% style="color:blue" %)**AT+TRIG1=1,100**(%%)** (set DI1 port to trigger on high level, valid signal is 100ms ) ** 411 411 412 -(% class="box infomessage" %) 413 -((( 414 -((( 415 -**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 416 -))) 417 -))) 435 +(% style="color:blue" %)**AT+TRIG2=0,100**(%%)** (set DI2 port to trigger on low level, valid signal is 100ms) ** 418 418 419 -(% class="box infomessage" %) 420 -((( 421 -((( 422 -**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 423 -))) 424 -))) 437 +(% style="color:blue" %)**AT+TRIG2=1,100**(%%)** (set DI2 port to trigger on high level, valid signal is 100ms ) ** 425 425 426 -(% class="box infomessage" %) 427 -((( 428 -((( 429 -**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 439 +(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 440 + 441 +(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 430 430 ))) 431 -))) 432 432 433 433 434 434 435 435 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 436 436 448 + 437 437 **LT22222-L**: This mode the DI1 is used as a counting pin. 438 438 439 439 [[image:image-20220523181246-5.png]] 440 440 441 441 ((( 454 + 455 + 442 442 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 443 443 ))) 444 444 ... ... @@ -449,9 +449,10 @@ 449 449 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 450 450 451 451 ((( 452 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 466 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 453 453 ))) 454 454 469 + 455 455 ((( 456 456 **To use counting mode, please run:** 457 457 ))) ... ... @@ -460,12 +460,7 @@ 460 460 ((( 461 461 ((( 462 462 **AT+MOD=3** 463 -))) 464 -))) 465 465 466 -(% class="box infomessage" %) 467 -((( 468 -((( 469 469 **ATZ** 470 470 ))) 471 471 ))) ... ... @@ -472,11 +472,10 @@ 472 472 473 473 ((( 474 474 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 475 - 476 - 477 477 ))) 478 478 479 479 488 + 480 480 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 481 481 482 482 ... ... @@ -498,7 +498,7 @@ 498 498 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 499 499 500 500 ((( 501 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 510 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 502 502 ))) 503 503 504 504 ((( ... ... @@ -511,20 +511,13 @@ 511 511 ((( 512 512 ((( 513 513 **AT+MOD=4** 514 -))) 515 -))) 516 516 517 -(% class="box infomessage" %) 518 -((( 519 -((( 520 520 **ATZ** 521 521 ))) 522 522 ))) 523 523 524 -((( 525 - 526 -))) 527 527 529 + 528 528 ((( 529 529 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 530 530 ))) ... ... @@ -533,35 +533,16 @@ 533 533 534 534 535 535 **Plus below command for AVI1 Counting:** 536 -))) 537 537 538 -(% class="box infomessage" %) 539 -((( 540 -((( 541 -**AT+SETCNT=3,60 (set AVI Count to 60)** 542 -))) 543 -))) 544 544 545 -(% class="box infomessage" %) 546 -((( 547 -((( 548 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 549 -))) 550 -))) 540 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 551 551 552 -(% class="box infomessage" %) 553 -((( 554 -((( 555 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 556 -))) 557 -))) 542 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 558 558 559 -(% class="box infomessage" %) 560 -((( 561 -((( 562 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 544 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 545 + 546 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 563 563 ))) 564 -))) 565 565 566 566 567 567 ... ... @@ -585,7 +585,7 @@ 585 585 ))) 586 586 587 587 ((( 588 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 571 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 589 589 ))) 590 590 591 591 ((( ... ... @@ -598,12 +598,7 @@ 598 598 ((( 599 599 ((( 600 600 **AT+MOD=5** 601 -))) 602 -))) 603 603 604 -(% class="box infomessage" %) 605 -((( 606 -((( 607 607 **ATZ** 608 608 ))) 609 609 ))) ... ... @@ -621,10 +621,11 @@ 621 621 622 622 For example, if user has configured below commands: 623 623 624 -* **AT+MOD=1 ** **~-~->** The normal working mode 625 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 602 +* **AT+MOD=1 ** **~-~->** The normal working mode 603 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 626 626 627 627 606 + 628 628 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 629 629 630 630 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type ... ... @@ -632,12 +632,15 @@ 632 632 633 633 634 634 635 -**AT Command to set Trigger Condition**: 636 636 615 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 616 + 617 + 637 637 (% style="color:#4f81bd" %)**Trigger base on voltage**: 638 638 639 639 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 640 640 622 + 641 641 **Example:** 642 642 643 643 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) ... ... @@ -650,6 +650,7 @@ 650 650 651 651 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 652 652 635 + 653 653 **Example:** 654 654 655 655 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) ... ... @@ -668,8 +668,9 @@ 668 668 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 669 669 670 670 671 -**Downlink Command to set Trigger Condition:** 672 672 655 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 656 + 673 673 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 674 674 675 675 Format: AA xx yy1 yy1 yy2 yy2 yy3 yy3 yy4 yy4 ... ... @@ -718,6 +718,7 @@ 718 718 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 719 719 720 720 705 + 721 721 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 722 722 723 723 [[image:image-20220524090249-3.png]] ... ... @@ -731,6 +731,7 @@ 731 731 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 732 732 733 733 719 + 734 734 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 735 735 736 736 [[image:image-20220524090456-4.png]] ... ... @@ -746,6 +746,7 @@ 746 746 00000101: Means both DI1 and DI2 trigger are enabled. 747 747 748 748 735 + 749 749 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 750 750 751 751 Downlink command to poll MOD6 status: ... ... @@ -756,14 +756,13 @@ 756 756 757 757 758 758 746 + 759 759 === 3.3.7 Payload Decoder === 760 760 761 761 ((( 762 762 763 763 764 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 765 - 766 - 752 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 767 767 ))) 768 768 769 769 ... ... @@ -770,6 +770,7 @@ 770 770 771 771 == 3.4 Configure LT via AT or Downlink == 772 772 759 + 773 773 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 774 774 775 775 ((( ... ... @@ -782,8 +782,10 @@ 782 782 783 783 784 784 772 + 785 785 === 3.4.1 Common Commands === 786 786 775 + 787 787 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 788 788 789 789 ... ... @@ -790,80 +790,73 @@ 790 790 791 791 === 3.4.2 Sensor related commands === 792 792 782 + 793 793 ==== 3.4.2.1 Set Transmit Interval ==== 794 794 785 + 795 795 Set device uplink interval. 796 796 797 -* AT Command: 788 +* (% style="color:#037691" %)**AT Command:** 798 798 799 -(% class="box infomessage" %) 800 -((( 801 801 **AT+TDC=N ** 802 -))) 803 803 792 + 804 804 **Example: **AT+TDC=30000. Means set interval to 30 seconds 805 805 806 806 807 -* Downlink Payload (prefix 0x01): 796 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 808 808 809 -(% class="box infomessage" %) 810 -((( 811 811 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 812 -))) 813 813 814 814 815 815 802 + 816 816 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 817 817 805 + 818 818 Set work mode. 819 819 820 -* AT Command: 808 +* (% style="color:#037691" %)**AT Command:** 821 821 822 -(% class="box infomessage" %) 823 -((( 824 824 **AT+MOD=N ** 825 -))) 826 826 812 + 827 827 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 828 828 829 829 830 -* Downlink Payload (prefix 0x0A): 816 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 831 831 832 -(% class="box infomessage" %) 833 -((( 834 -**0x0A aa ~/~/ Same as AT+MOD=aa** 835 -))) 818 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 836 836 837 837 838 838 822 + 839 839 ==== 3.4.2.3 Poll an uplink ==== 840 840 841 -* AT Command: 842 842 826 +* (% style="color:#037691" %)**AT Command:** 827 + 843 843 There is no AT Command to poll uplink 844 844 845 845 846 -* Downlink Payload (prefix 0x08): 831 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 847 847 848 -(% class="box infomessage" %) 849 -((( 850 -**0x08 FF ~/~/ Poll an uplink,** 851 -))) 833 +**0x08 FF **~/~/ Poll an uplink 852 852 835 + 853 853 **Example**: 0x08FF, ask device to send an Uplink 854 854 855 855 856 856 840 + 857 857 ==== 3.4.2.4 Enable Trigger Mode ==== 858 858 843 + 859 859 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 860 860 861 -* AT Command: 846 +* (% style="color:#037691" %)**AT Command:** 862 862 863 -(% class="box infomessage" %) 864 -((( 865 865 **AT+ADDMOD6=1 or 0** 866 -))) 867 867 868 868 1: Enable Trigger Mode 869 869 ... ... @@ -870,43 +870,38 @@ 870 870 0: Disable Trigger Mode 871 871 872 872 873 -* Downlink Payload (prefix 0x0A 06): 855 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 874 874 875 -(% class="box infomessage" %) 876 -((( 877 -**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 878 -))) 857 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 879 879 880 880 881 881 861 + 882 882 ==== 3.4.2.5 Poll trigger settings ==== 883 883 864 + 884 884 Poll trigger settings, 885 885 886 -* AT Command: 867 +* (% style="color:#037691" %)**AT Command:** 887 887 888 888 There is no AT Command for this feature. 889 889 890 890 891 -* Downlink Payload (prefix 0x AB 06): 872 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 892 892 893 -(% class="box infomessage" %) 894 -((( 895 -**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 896 -))) 874 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 897 897 898 898 899 899 878 + 900 900 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 901 901 881 + 902 902 Enable Disable DI1/DI2/DI2 as trigger, 903 903 904 -* AT Command: 884 +* (% style="color:#037691" %)**AT Command:** 905 905 906 -(% class="box infomessage" %) 907 -((( 908 908 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 909 -))) 910 910 911 911 912 912 **Example:** ... ... @@ -913,25 +913,21 @@ 913 913 914 914 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 915 915 916 -* Downlink Payload (prefix 0xAA 02): 893 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 917 917 918 -(% class="box infomessage" %) 919 -((( 920 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 921 -))) 895 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 922 922 923 923 924 924 899 + 925 925 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 926 926 902 + 927 927 Set DI1 or DI3(for LT-33222-L) trigger. 928 928 929 -* AT Command: 905 +* (% style="color:#037691" %)**AT Command:** 930 930 931 -(% class="box infomessage" %) 932 -((( 933 933 **AT+TRIG1=a,b** 934 -))) 935 935 936 936 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 937 937 ... ... @@ -943,26 +943,22 @@ 943 943 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 944 944 945 945 946 -* Downlink Payload (prefix 0x09 01 ): 919 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 920 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 947 947 948 -(% class="box infomessage" %) 949 -((( 950 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 951 -))) 952 952 953 953 954 954 955 955 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 956 956 927 + 957 957 Set DI2 trigger. 958 958 959 -* AT Command: 930 +* (% style="color:#037691" %)**AT Command:** 960 960 961 -(% class="box infomessage" %) 962 -((( 963 963 **AT+TRIG2=a,b** 964 -))) 965 965 934 + 966 966 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 967 967 968 968 b : delay timing. ... ... @@ -973,93 +973,82 @@ 973 973 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 974 974 975 975 976 -* Downlink Payload (prefix 0x09 02 ): 945 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 977 977 978 -(% class="box infomessage" %) 979 -((( 980 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 981 -))) 947 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 982 982 983 983 984 984 951 + 985 985 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 986 986 954 + 987 987 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 988 988 989 -* AT Command :957 +* (% style="color:#037691" %)**AT Command** 990 990 991 -(% class="box infomessage" %) 992 -((( 993 -**AT+ACLIM. ** 994 -))) 959 +**AT+ACLIM** 995 995 996 996 997 -* Downlink Payload (prefix 0xAA 01 ) :962 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 998 998 999 -(% class="box infomessage" %) 1000 -((( 1001 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1002 -))) 964 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1003 1003 1004 1004 1005 1005 968 + 1006 1006 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1007 1007 971 + 1008 1008 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1009 1009 1010 -* AT Command :974 +* (% style="color:#037691" %)**AT Command** 1011 1011 1012 -(% class="box infomessage" %) 1013 -((( 1014 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1015 -))) 976 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1016 1016 1017 1017 1018 -* Downlink Payload (prefix 0xAA 00 ) :979 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 1019 1019 1020 -(% class="box infomessage" %) 1021 -((( 1022 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 1023 -))) 981 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1024 1024 1025 1025 1026 1026 985 + 1027 1027 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1028 1028 1029 -Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1030 1030 1031 - *ATCommand:989 +Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 1032 1032 1033 -(% class="box infomessage" %) 1034 -((( 1035 -**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 1036 -))) 991 +* (% style="color:#037691" %)**AT Command** 1037 1037 993 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 1038 1038 1039 -* Downlink Payload (prefix 0xAC ): 1040 1040 1041 -(% class="box infomessage" %) 996 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 997 + 998 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 999 + 1042 1042 ((( 1043 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 1001 + 1002 + 1003 +(% style="color:red" %)**Note: ATDC setting must be more than 5min** 1044 1044 ))) 1045 1045 1046 1046 1047 1047 1008 + 1048 1048 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1049 1049 1050 -* AT Command: 1051 1051 1012 +* (% style="color:#037691" %)**AT Command** 1013 + 1052 1052 There is no AT Command to control Digital Output 1053 1053 1054 1054 1055 -* Downlink Payload (prefix 0x02): 1017 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 1018 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1056 1056 1057 -(% class="box infomessage" %) 1058 1058 ((( 1059 -**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1060 -))) 1061 - 1062 -((( 1063 1063 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 1064 1064 ))) 1065 1065 ... ... @@ -1070,31 +1070,29 @@ 1070 1070 [[image:image-20220524092754-5.png]] 1071 1071 1072 1072 ((( 1073 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 1031 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** 1074 1074 ))) 1075 1075 1076 1076 ((( 1077 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1035 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1078 1078 ))) 1079 1079 1080 1080 1081 1081 1040 + 1082 1082 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1083 1083 1084 -* AT Command: 1085 1085 1044 +* (% style="color:#037691" %)**AT Command** 1045 + 1086 1086 There is no AT Command to control Digital Output 1087 1087 1088 1088 1089 -* Downlink Payload (prefix 0xA9) :1049 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1090 1090 1091 -(% class="box infomessage" %) 1092 -((( 1093 -((( 1094 -**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1095 -))) 1096 -))) 1051 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1097 1097 1053 + 1098 1098 This is to control the digital output time of DO pin. Include four bytes: 1099 1099 1100 1100 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1121,11 +1121,11 @@ 1121 1121 [[image:image-20220524093351-8.png]] 1122 1122 1123 1123 1124 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1080 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1125 1125 1126 1126 Latching time. Unit: ms 1127 1127 1128 -Device will upload a packet if downlink code executes successfully. 1084 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1129 1129 1130 1130 1131 1131 **Example payload:** ... ... @@ -1148,20 +1148,20 @@ 1148 1148 1149 1149 1150 1150 1107 + 1151 1151 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1152 1152 1153 -* AT Command: 1154 1154 1111 +* (% style="color:#037691" %)**AT Command:** 1112 + 1155 1155 There is no AT Command to control Relay Output 1156 1156 1157 1157 1158 -* Downlink Payload (prefix 0x03): 1116 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1159 1159 1160 -(% class="box infomessage" %) 1161 -((( 1162 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1163 -))) 1118 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1164 1164 1120 + 1165 1165 ((( 1166 1166 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1167 1167 ))) ... ... @@ -1174,24 +1174,24 @@ 1174 1174 [[image:image-20220524093724-9.png]] 1175 1175 ))) 1176 1176 1177 -Device will upload a packet if downlink code executes successfully. 1133 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1178 1178 1179 1179 1180 1180 1137 + 1181 1181 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1182 1182 1183 -* AT Command: 1184 1184 1141 +* (% style="color:#037691" %)**AT Command:** 1142 + 1185 1185 There is no AT Command to control Relay Output 1186 1186 1187 1187 1188 -* Downlink Payload (prefix 0x05): 1146 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1189 1189 1190 -(% class="box infomessage" %) 1191 -((( 1192 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1193 -))) 1148 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1194 1194 1150 + 1195 1195 This is to control the relay output time of relay. Include four bytes: 1196 1196 1197 1197 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1205,63 +1205,57 @@ 1205 1205 1206 1206 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1207 1207 1208 -[[image:image-20220 524093831-10.png]]1164 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1209 1209 1210 1210 1211 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1167 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1212 1212 1213 -Device will upload a packet if downlink code executes successfully. 1169 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1214 1214 1215 1215 1216 1216 **Example payload:** 1217 1217 1218 -**~1. 05 01 11 07 D 0**1174 +**~1. 05 01 11 07 D** 1219 1219 1220 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1176 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1221 1221 1222 1222 **2. 05 01 10 07 D0** 1223 1223 1224 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1180 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1225 1225 1226 1226 **3. 05 00 01 07 D0** 1227 1227 1228 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1184 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1229 1229 1230 1230 **4. 05 00 00 07 D0** 1231 1231 1232 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1188 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1233 1233 1234 1234 1235 1235 1236 1236 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1237 1237 1194 + 1238 1238 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1239 1239 1240 -* AT Command: 1197 +* (% style="color:#037691" %)**AT Command:** 1241 1241 1242 -(% class="box infomessage" %) 1243 -((( 1244 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1245 -))) 1199 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1246 1246 1247 1247 1248 -* Downlink Payload (prefix 0xA5): 1202 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1249 1249 1250 -(% class="box infomessage" %) 1251 -((( 1252 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1253 -))) 1204 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1254 1254 1255 1255 1256 1256 1208 + 1257 1257 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1258 1258 1259 -* AT Command: 1260 1260 1261 -(% class="box infomessage" %)1262 - (((1212 +* (% style="color:#037691" %)**AT Command:** 1213 + 1263 1263 **AT+SETCNT=aa,(bb cc dd ee) ** 1264 -))) 1265 1265 1266 1266 aa: 1: Set count1, 1267 1267 ... ... @@ -1272,60 +1272,163 @@ 1272 1272 Bb cc dd ee: number to be set 1273 1273 1274 1274 1275 -* Downlink Payload (prefix 0xA8): 1225 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1276 1276 1277 -(% class="box infomessage" %) 1278 -((( 1279 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1280 -))) 1227 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1281 1281 1282 1282 1283 1283 1231 + 1284 1284 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1285 1285 1234 + 1286 1286 Clear counting for counting mode 1287 1287 1288 -* AT Command: 1237 +* (% style="color:#037691" %)**AT Command:** 1289 1289 1290 -(% class="box infomessage" %) 1291 -((( 1292 -**AT+CLRCOUNT ~/~/ clear all counting** 1293 -))) 1239 +**AT+CLRCOUNT ** ~/~/ clear all counting 1294 1294 1295 -* Downlink Payload (prefix 0xA6): 1296 1296 1297 -(% class="box infomessage" %) 1298 -((( 1299 -**0x A6 01 ~/~/ clear all counting,** 1300 -))) 1242 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1301 1301 1244 +**0x A6 01 ** ~/~/ clear all counting 1302 1302 1303 1303 1247 + 1248 + 1304 1304 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1305 1305 1306 -* AT Command: 1307 1307 1308 -(% class="box infomessage" %) 1309 -((( 1310 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1311 -))) 1252 +* (% style="color:#037691" %)**AT Command:** 1312 1312 1313 -* DownlinkPayload(prefix0xA7):1254 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1314 1314 1315 -(% class="box infomessage" %) 1256 + 1257 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1258 + 1259 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1260 + 1316 1316 ((( 1317 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1262 +range: aa bb cc:0 to 16777215, (unit:second) 1263 + 1264 + 1265 + 1266 + 1318 1318 ))) 1319 1319 1269 +==== 3.4.2.20 Reset save DR DO state ==== 1270 + 1271 + 1272 +* (% style="color:#037691" %)**AT Command:** 1273 + 1274 +**AT+RODORET=1 **~/~/ RODO will close when the device joining the network. (default) 1275 + 1276 +**AT+RODORET=0 **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1277 + 1278 + 1279 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1280 + 1281 +**0x AD aa **~/~/ same as AT+RODORET =aa 1282 + 1320 1320 ((( 1321 - range:aa bb cc:0 to 16777215, (unit:second)1284 + 1322 1322 1286 + 1287 + 1288 +==== 3.4.2.21 Encrypted payload ==== 1289 + 1290 + 1291 +* (% style="color:#037691" %)**AT Command:** 1292 + 1293 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1294 + 1295 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1296 + 1297 + 1298 + 1299 + 1300 +==== 3.4.2.22 Get sensor value ==== 1301 + 1302 + 1303 +* (% style="color:#037691" %)**AT Command:** 1304 + 1305 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1306 + 1307 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1308 + 1309 + 1310 + 1311 + 1312 +==== 3.4.2.23 Resets the downlink packet count ==== 1313 + 1314 + 1315 +* (% style="color:#037691" %)**AT Command:** 1316 + 1317 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1318 + 1319 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1320 + 1321 + 1322 + 1323 + 1324 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1325 + 1326 + 1327 +* (% style="color:#037691" %)**AT Command:** 1328 + 1329 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1330 + 1331 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1332 + 1333 + 1334 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1335 + 1336 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1337 + 1338 + 1339 + 1340 + 1341 +==== 3.4.2.25 Copy downlink to uplink ==== 1342 + 1343 + 1344 +* (% style="color:#037691" %)**AT Command**(%%)**:** 1345 + 1346 + **AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1347 + 1348 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1349 + 1350 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1351 + 1352 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1353 + 1354 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1355 + 1356 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1357 + 1358 + 1359 + 1360 +==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1361 + 1362 + 1363 +* ((( 1364 +(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1365 + 1366 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1367 + 1323 1323 1324 1324 ))) 1325 1325 1371 +**Example:** 1326 1326 1373 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1374 + 1375 + 1376 + 1377 +))) 1378 + 1327 1327 == 3.5 Integrate with Mydevice == 1328 1328 1381 + 1329 1329 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1330 1330 1331 1331 ((( ... ... @@ -1334,14 +1334,15 @@ 1334 1334 1335 1335 ((( 1336 1336 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1390 + 1391 + 1337 1337 ))) 1338 1338 1339 -[[image:1 653356737703-362.png||height="232" width="732"]]1394 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1340 1340 1341 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1342 1342 1343 1343 1344 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1398 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1345 1345 1346 1346 1347 1347 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1374,8 +1374,10 @@ 1374 1374 1375 1375 == 3.6 Interface Detail == 1376 1376 1431 + 1377 1377 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1378 1378 1434 + 1379 1379 Support NPN Type sensor 1380 1380 1381 1381 [[image:1653356991268-289.png]] ... ... @@ -1384,6 +1384,7 @@ 1384 1384 1385 1385 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1386 1386 1443 + 1387 1387 ((( 1388 1388 The DI port of LT-22222-L can support NPN or PNP output sensor. 1389 1389 ))) ... ... @@ -1390,7 +1390,9 @@ 1390 1390 1391 1391 ((( 1392 1392 ((( 1393 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1450 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1451 + 1452 + 1394 1394 ))) 1395 1395 ))) 1396 1396 ... ... @@ -1415,10 +1415,10 @@ 1415 1415 ))) 1416 1416 1417 1417 * ((( 1418 -Connect sensor ’s output to DI1-1477 +Connect sensor's output to DI1- 1419 1419 ))) 1420 1420 * ((( 1421 -Connect sensor ’s VCC to DI1+.1480 +Connect sensor's VCC to DI1+. 1422 1422 ))) 1423 1423 1424 1424 ((( ... ... @@ -1426,15 +1426,17 @@ 1426 1426 ))) 1427 1427 1428 1428 ((( 1429 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1488 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.** 1430 1430 ))) 1431 1431 1432 1432 ((( 1433 -If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1492 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1434 1434 ))) 1435 1435 1436 1436 ((( 1437 1437 1497 + 1498 + 1438 1438 ))) 1439 1439 1440 1440 ((( ... ... @@ -1446,10 +1446,10 @@ 1446 1446 ))) 1447 1447 1448 1448 * ((( 1449 -Connect sensor ’s output to DI1+1510 +Connect sensor's output to DI1+ 1450 1450 ))) 1451 1451 * ((( 1452 -Connect sensor ’s GND DI1-.1513 +Connect sensor's GND DI1-. 1453 1453 ))) 1454 1454 1455 1455 ((( ... ... @@ -1466,6 +1466,8 @@ 1466 1466 1467 1467 ((( 1468 1468 1530 + 1531 + 1469 1469 ))) 1470 1470 1471 1471 ((( ... ... @@ -1477,10 +1477,10 @@ 1477 1477 ))) 1478 1478 1479 1479 * ((( 1480 -Connect sensor ’s output to DI1+ with a serial 50K resistor1543 +Connect sensor's output to DI1+ with a serial 50K resistor 1481 1481 ))) 1482 1482 * ((( 1483 -Connect sensor ’s GND DI1-.1546 +Connect sensor's GND DI1-. 1484 1484 ))) 1485 1485 1486 1486 ((( ... ... @@ -1499,6 +1499,7 @@ 1499 1499 1500 1500 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1501 1501 1565 + 1502 1502 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1503 1503 1504 1504 [[image:1653357531600-905.png]] ... ... @@ -1507,6 +1507,7 @@ 1507 1507 1508 1508 === 3.6.4 Analog Input Interface === 1509 1509 1574 + 1510 1510 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1511 1511 1512 1512 ... ... @@ -1538,6 +1538,7 @@ 1538 1538 1539 1539 === 3.6.5 Relay Output === 1540 1540 1606 + 1541 1541 ((( 1542 1542 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1543 1543 ))) ... ... @@ -1544,6 +1544,7 @@ 1544 1544 1545 1545 [[image:image-20220524100215-9.png]] 1546 1546 1613 + 1547 1547 [[image:image-20220524100215-10.png||height="382" width="723"]] 1548 1548 1549 1549 ... ... @@ -1550,13 +1550,17 @@ 1550 1550 1551 1551 == 3.7 LEDs Indicators == 1552 1552 1620 + 1553 1553 [[image:image-20220524100748-11.png]] 1554 1554 1555 1555 1624 + 1556 1556 = 4. Use AT Command = 1557 1557 1627 + 1558 1558 == 4.1 Access AT Command == 1559 1559 1630 + 1560 1560 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1561 1561 1562 1562 [[image:1653358238933-385.png]] ... ... @@ -1755,8 +1755,6 @@ 1755 1755 1756 1756 ((( 1757 1757 AT+CFG: Print all settings 1758 - 1759 - 1760 1760 ))) 1761 1761 1762 1762 ... ... @@ -1763,6 +1763,7 @@ 1763 1763 1764 1764 == 4.2 Common AT Command Sequence == 1765 1765 1835 + 1766 1766 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1767 1767 1768 1768 ((( ... ... @@ -1802,8 +1802,6 @@ 1802 1802 1803 1803 ((( 1804 1804 (% style="background-color:#dcdcdc" %)ATZ 1805 - 1806 - 1807 1807 ))) 1808 1808 1809 1809 ... ... @@ -1875,6 +1875,8 @@ 1875 1875 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1876 1876 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1877 1877 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1946 + 1947 + 1878 1878 ))) 1879 1879 1880 1880 ((( ... ... @@ -1888,13 +1888,16 @@ 1888 1888 1889 1889 === 4.2.3 Change to Class A === 1890 1890 1961 + 1891 1891 If sensor JOINED 1892 1892 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1893 1893 ATZ 1894 1894 1895 1895 1967 + 1896 1896 = 5. FAQ = 1897 1897 1970 + 1898 1898 == 5.1 How to upgrade the image? == 1899 1899 1900 1900 ... ... @@ -1911,12 +1911,14 @@ 1911 1911 1912 1912 ((( 1913 1913 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1914 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dr agino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].1987 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 1915 1915 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1916 1916 1917 1917 1918 1918 (% style="color:blue" %)**For LT-22222-L**(%%): 1919 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1992 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1993 + 1994 + 1920 1920 ))) 1921 1921 1922 1922 [[image:image-20220524103407-12.png]] ... ... @@ -1928,6 +1928,7 @@ 1928 1928 1929 1929 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1930 1930 2006 + 1931 1931 [[image:1653360054704-518.png||height="186" width="745"]] 1932 1932 1933 1933 ... ... @@ -1936,6 +1936,8 @@ 1936 1936 1937 1937 1938 1938 == 5.2 How to change the LoRa Frequency Bands/Region? == 2015 + 2016 + 1939 1939 ))) 1940 1940 ))) 1941 1941 ... ... @@ -1946,7 +1946,10 @@ 1946 1946 ((( 1947 1947 1948 1948 2027 + 1949 1949 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2029 + 2030 + 1950 1950 ))) 1951 1951 1952 1952 ((( ... ... @@ -1959,25 +1959,33 @@ 1959 1959 ((( 1960 1960 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1961 1961 2043 + 1962 1962 1963 1963 ))) 1964 1964 ))) 1965 1965 1966 1966 ((( 1967 -(% style="color:#4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2049 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2050 + 2051 + 1968 1968 ))) 1969 1969 1970 1970 ((( 1971 1971 [[image:1653360231087-571.png||height="401" width="727"]] 2056 + 2057 + 1972 1972 ))) 1973 1973 1974 1974 ((( 1975 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 2061 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1976 1976 ))) 1977 1977 1978 1978 2065 + 1979 1979 ((( 1980 -(% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2067 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2068 + 2069 + 1981 1981 ))) 1982 1982 1983 1983 ((( ... ... @@ -2001,26 +2001,48 @@ 2001 2001 [[image:1653360498588-932.png||height="485" width="726"]] 2002 2002 2003 2003 2093 + 2004 2004 == 5.4 Can I see counting event in Serial? == 2005 2005 2096 + 2006 2006 ((( 2007 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.2098 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2008 2008 2009 2009 2101 + 2010 2010 == 5.5 Can i use point to point communication for LT-22222-L? == 2011 2011 2104 + 2012 2012 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 2106 + 2107 + 2108 + 2013 2013 ))) 2014 2014 2015 2015 ((( 2016 - 2112 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2017 2017 2114 + 2115 +If the device is not shut down, but directly powered off. 2116 + 2117 +It will default that this is a power-off state. 2118 + 2119 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 2120 + 2121 +After restart, the status before power failure will be read from flash. 2122 + 2123 + 2124 + 2018 2018 = 6. Trouble Shooting = 2126 + 2127 + 2019 2019 ))) 2020 2020 2021 2021 ((( 2022 2022 ((( 2023 -== 6.1 Downlink doesn’t work, how to solve it? == 2132 +== 6.1 Downlink doesn't work, how to solve it? == 2133 + 2134 + 2024 2024 ))) 2025 2025 ))) 2026 2026 ... ... @@ -2031,7 +2031,10 @@ 2031 2031 ((( 2032 2032 2033 2033 2145 + 2034 2034 == 6.2 Have trouble to upload image. == 2147 + 2148 + 2035 2035 ))) 2036 2036 2037 2037 ((( ... ... @@ -2041,7 +2041,10 @@ 2041 2041 ((( 2042 2042 2043 2043 2044 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 2158 + 2159 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2160 + 2161 + 2045 2045 ))) 2046 2046 2047 2047 ((( ... ... @@ -2055,19 +2055,21 @@ 2055 2055 2056 2056 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 2057 2057 2058 - 2059 2059 (% style="color:#4f81bd" %)**XXX:** 2060 2060 2061 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4332062 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8682063 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9202064 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4702065 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9232066 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9152067 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9152068 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8652069 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792177 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2178 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2179 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2180 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2181 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2182 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2183 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2184 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2185 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2070 2070 2187 + 2188 + 2189 + 2071 2071 = 8. Packing Info = 2072 2072 2073 2073 ... ... @@ -2085,18 +2085,28 @@ 2085 2085 * Package Size / pcs : 14.5 x 8 x 5 cm 2086 2086 * Weight / pcs : 170g 2087 2087 2207 + 2208 + 2209 + 2088 2088 = 9. Support = 2089 2089 2212 + 2090 2090 * ((( 2091 2091 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 2092 2092 ))) 2093 2093 * ((( 2094 2094 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2218 + 2219 + 2220 + 2221 + 2095 2095 ))) 2096 2096 2097 2097 = 10. Reference = 2098 2098 2226 + 2099 2099 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2100 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 2101 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2228 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2102 2102 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2230 + 2231 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content