From version < 77.97 >
edited by Xiaoling
on 2022/06/10 09:32
To version < 77.89 >
edited by Xiaoling
on 2022/06/10 09:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -275,7 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -283,8 +283,6 @@
283 283  [[image:image-20220523174024-3.png]]
284 284  
285 285  (((
286 -
287 -
288 288  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
289 289  )))
290 290  
... ... @@ -315,7 +315,6 @@
315 315  * [0] RO2 relay channel is open and RO2 LED is OFF;
316 316  
317 317  
318 -
319 319  **LT22222-L:**
320 320  
321 321  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -332,6 +332,7 @@
332 332  ** DO1 LED is off in both case
333 333  
334 334  
331 +
335 335  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
336 336  
337 337  
... ... @@ -624,14 +624,11 @@
624 624  * **AT+MOD=1 ** **~-~->** The normal working mode
625 625  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
626 626  
627 -
628 628  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
629 629  
630 630  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
631 631  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
632 632  
633 -
634 -
635 635  **AT Command to set Trigger Condition**:
636 636  
637 637  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -645,7 +645,6 @@
645 645  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
646 646  
647 647  
648 -
649 649  (% style="color:#4f81bd" %)**Trigger base on current**:
650 650  
651 651  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -655,7 +655,6 @@
655 655  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
656 656  
657 657  
658 -
659 659  (% style="color:#4f81bd" %)**Trigger base on DI status**:
660 660  
661 661  DI status trigger Flag.
... ... @@ -662,13 +662,12 @@
662 662  
663 663  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
664 664  
665 -
666 666  **Example:**
667 667  
668 668  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
669 669  
670 670  
671 -**Downlink Command to set Trigger Condition:**
662 +**Downlink Command to set Trigger Condition**
672 672  
673 673  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
674 674  
... ... @@ -697,7 +697,6 @@
697 697  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
698 698  
699 699  
700 -
701 701  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
702 702  
703 703  MOD6 Payload : total 11 bytes payload
... ... @@ -711,8 +711,6 @@
711 711  
712 712  * Each bits shows if the corresponding trigger has been configured.
713 713  
714 -
715 -
716 716  **Example:**
717 717  
718 718  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -724,8 +724,6 @@
724 724  
725 725  * Each bits shows which status has been trigger on this uplink.
726 726  
727 -
728 -
729 729  **Example:**
730 730  
731 731  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -737,8 +737,6 @@
737 737  
738 738  * Each bits shows which status has been trigger on this uplink.
739 739  
740 -
741 -
742 742  **Example:**
743 743  
744 744  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -781,7 +781,6 @@
781 781  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
782 782  
783 783  
784 -
785 785  === 3.4.1 Common Commands ===
786 786  
787 787  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved