Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -622,14 +622,11 @@ 622 622 * **AT+MOD=1 ** **~-~->** The normal working mode 623 623 * **AT+ADDMOD6=1** **~-~->** Enable trigger 624 624 625 - 626 626 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 627 627 628 628 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 629 629 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 630 630 631 - 632 - 633 633 **AT Command to set Trigger Condition**: 634 634 635 635 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -643,7 +643,6 @@ 643 643 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 644 644 645 645 646 - 647 647 (% style="color:#4f81bd" %)**Trigger base on current**: 648 648 649 649 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -653,7 +653,6 @@ 653 653 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 654 654 655 655 656 - 657 657 (% style="color:#4f81bd" %)**Trigger base on DI status**: 658 658 659 659 DI status trigger Flag. ... ... @@ -660,13 +660,12 @@ 660 660 661 661 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 662 662 663 - 664 664 **Example:** 665 665 666 666 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 667 667 668 668 669 -**Downlink Command to set Trigger Condition :**663 +**Downlink Command to set Trigger Condition** 670 670 671 671 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 672 672 ... ... @@ -695,7 +695,6 @@ 695 695 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 696 696 697 697 698 - 699 699 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 700 700 701 701 MOD6 Payload : total 11 bytes payload ... ... @@ -709,8 +709,6 @@ 709 709 710 710 * Each bits shows if the corresponding trigger has been configured. 711 711 712 - 713 - 714 714 **Example:** 715 715 716 716 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW