... ... @@ -275,7 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -283,8 +283,6 @@
283 283  [[image:image-20220523174024-3.png]]
284 284  
285 285  (((
286 -
287 -
288 288  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
289 289  )))
290 290  
... ... @@ -314,6 +314,7 @@
314 314  * [1] RO1 relay channel is close and the RO1 LED is ON.
315 315  * [0] RO2 relay channel is open and RO2 LED is OFF;
316 316  
314 +
317 317  **LT22222-L:**
318 318  
319 319  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -330,6 +330,7 @@
330 330  ** DO1 LED is off in both case
331 331  
332 332  
331 +
333 333  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
334 334  
335 335  
... ... @@ -622,14 +622,11 @@
622 622  * **AT+MOD=1 ** **~-~->** The normal working mode
623 623  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
624 624  
625 -
626 626  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
627 627  
628 628  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
629 629  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
630 630  
631 -
632 -
633 633  **AT Command to set Trigger Condition**:
634 634  
635 635  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -643,7 +643,6 @@
643 643  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
644 644  
645 645  
646 -
647 647  (% style="color:#4f81bd" %)**Trigger base on current**:
648 648  
649 649  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -653,7 +653,6 @@
653 653  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
654 654  
655 655  
656 -
657 657  (% style="color:#4f81bd" %)**Trigger base on DI status**:
658 658  
659 659  DI status trigger Flag.
... ... @@ -660,13 +660,12 @@
660 660  
661 661  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
662 662  
663 -
664 664  **Example:**
665 665  
666 666  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
667 667  
668 668  
669 -**Downlink Command to set Trigger Condition:**
662 +**Downlink Command to set Trigger Condition**
670 670  
671 671  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
672 672  
... ... @@ -695,7 +695,6 @@
695 695  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
696 696  
697 697  
698 -
699 699  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
700 700  
701 701  MOD6 Payload : total 11 bytes payload
... ... @@ -709,8 +709,6 @@
709 709  
710 710  * Each bits shows if the corresponding trigger has been configured.
711 711  
712 -
713 -
714 714  **Example:**
715 715  
716 716  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -722,8 +722,6 @@
722 722  
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
725 -
726 -
727 727  **Example:**
728 728  
729 729  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -735,8 +735,6 @@
735 735  
736 736  * Each bits shows which status has been trigger on this uplink.
737 737  
738 -
739 -
740 740  **Example:**
741 741  
742 742  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -779,7 +779,6 @@
779 779  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
780 780  
781 781  
782 -
783 783  === 3.4.1 Common Commands ===
784 784  
785 785  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0