Last modified by Mengting Qiu on 2025/06/04 18:42

From version 77.96
edited by Xiaoling
on 2022/06/10 09:31
Change comment: There is no comment for this version
To version 77.60
edited by Xiaoling
on 2022/06/10 09:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -275,7 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -283,8 +283,6 @@
283 283  [[image:image-20220523174024-3.png]]
284 284  
285 285  (((
286 -
287 -
288 288  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
289 289  )))
290 290  
... ... @@ -298,7 +298,6 @@
298 298  
299 299  For example if payload is: [[image:image-20220523175847-2.png]]
300 300  
301 -
302 302  **The value for the interface is:  **
303 303  
304 304  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -329,10 +329,8 @@
329 329  ** DO1 is high in case there is load between DO1 and V+.
330 330  ** DO1 LED is off in both case
331 331  
332 -
333 333  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
334 334  
335 -
336 336  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
337 337  
338 338  (((
... ... @@ -341,7 +341,6 @@
341 341  
342 342  [[image:image-20220523180452-3.png]]
343 343  
344 -
345 345  (((
346 346  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
347 347  )))
... ... @@ -357,8 +357,6 @@
357 357  )))
358 358  
359 359  (((
360 -
361 -
362 362  **To use counting mode, please run:**
363 363  )))
364 364  
... ... @@ -377,8 +377,6 @@
377 377  )))
378 378  
379 379  (((
380 -
381 -
382 382  (% style="color:#4f81bd" %)**AT Commands for counting:**
383 383  )))
384 384  
... ... @@ -475,9 +475,9 @@
475 475  )))
476 476  
477 477  
467 +
478 478  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
479 479  
480 -
481 481  **LT22222-L**: This mode the DI1 is used as a counting pin.
482 482  
483 483  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -484,7 +484,6 @@
484 484  
485 485  [[image:image-20220523181903-8.png]]
486 486  
487 -
488 488  (((
489 489  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
490 490  )))
... ... @@ -500,8 +500,6 @@
500 500  )))
501 501  
502 502  (((
503 -
504 -
505 505  **To use this mode, please run:**
506 506  )))
507 507  
... ... @@ -528,8 +528,6 @@
528 528  )))
529 529  
530 530  (((
531 -
532 -
533 533  **Plus below command for AVI1 Counting:**
534 534  )))
535 535  
... ... @@ -565,14 +565,11 @@
565 565  
566 566  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
567 567  
568 -
569 569  **LT22222-L**: This mode the DI1 is used as a counting pin.
570 570  
571 571  [[image:image-20220523182334-9.png]]
572 572  
573 573  (((
574 -
575 -
576 576  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
577 577  )))
578 578  
... ... @@ -587,8 +587,6 @@
587 587  )))
588 588  
589 589  (((
590 -
591 -
592 592  **To use this mode, please run:**
593 593  )))
594 594  
... ... @@ -608,6 +608,8 @@
608 608  
609 609  (((
610 610  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
611 611  )))
612 612  
613 613  
... ... @@ -614,7 +614,6 @@
614 614  
615 615  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
616 616  
617 -
618 618  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
619 619  
620 620  For example, if user has configured below commands:
... ... @@ -622,14 +622,11 @@
622 622  * **AT+MOD=1 ** **~-~->** The normal working mode
623 623  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
624 624  
625 -
626 626  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
627 627  
628 628  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
629 629  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
630 630  
631 -
632 -
633 633  **AT Command to set Trigger Condition**:
634 634  
635 635  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -643,7 +643,6 @@
643 643  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
644 644  
645 645  
646 -
647 647  (% style="color:#4f81bd" %)**Trigger base on current**:
648 648  
649 649  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -653,7 +653,6 @@
653 653  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
654 654  
655 655  
656 -
657 657  (% style="color:#4f81bd" %)**Trigger base on DI status**:
658 658  
659 659  DI status trigger Flag.
... ... @@ -660,13 +660,12 @@
660 660  
661 661  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
662 662  
663 -
664 664  **Example:**
665 665  
666 666  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
667 667  
668 668  
669 -**Downlink Command to set Trigger Condition:**
643 +**Downlink Command to set Trigger Condition**
670 670  
671 671  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
672 672  
... ... @@ -684,18 +684,14 @@
684 684  
685 685   Yy4 yy4: AC2 or AV2 high limit.
686 686  
687 -
688 688  **Example1**: AA 00 13 88 00 00 00 00 00 00
689 689  
690 690  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
691 691  
692 -
693 693  **Example2**: AA 02 01 00
694 694  
695 695  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
696 696  
697 -
698 -
699 699  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
700 700  
701 701  MOD6 Payload : total 11 bytes payload
... ... @@ -702,7 +702,6 @@
702 702  
703 703  [[image:image-20220524085923-1.png]]
704 704  
705 -
706 706  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
707 707  
708 708  [[image:image-20220524090106-2.png]]
... ... @@ -709,8 +709,6 @@
709 709  
710 710  * Each bits shows if the corresponding trigger has been configured.
711 711  
712 -
713 -
714 714  **Example:**
715 715  
716 716  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -722,8 +722,6 @@
722 722  
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
725 -
726 -
727 727  **Example:**
728 728  
729 729  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -735,8 +735,6 @@
735 735  
736 736  * Each bits shows which status has been trigger on this uplink.
737 737  
738 -
739 -
740 740  **Example:**
741 741  
742 742  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -757,8 +757,6 @@
757 757  === 3.3.7 Payload Decoder ===
758 758  
759 759  (((
760 -
761 -
762 762  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
763 763  
764 764  
... ... @@ -778,8 +778,6 @@
778 778  
779 779  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
780 780  
781 -
782 -
783 783  === 3.4.1 Common Commands ===
784 784  
785 785  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -801,7 +801,6 @@
801 801  
802 802  **Example: **AT+TDC=30000. Means set interval to 30 seconds
803 803  
804 -
805 805  * Downlink Payload (prefix 0x01):
806 806  
807 807  (% class="box infomessage" %)
... ... @@ -824,7 +824,6 @@
824 824  
825 825  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
826 826  
827 -
828 828  * Downlink Payload (prefix 0x0A):
829 829  
830 830  (% class="box infomessage" %)
... ... @@ -840,7 +840,6 @@
840 840  
841 841  There is no AT Command to poll uplink
842 842  
843 -
844 844  * Downlink Payload (prefix 0x08):
845 845  
846 846  (% class="box infomessage" %)
... ... @@ -867,7 +867,6 @@
867 867  
868 868  0: Disable Trigger Mode
869 869  
870 -
871 871  * Downlink Payload (prefix 0x0A 06):
872 872  
873 873  (% class="box infomessage" %)
... ... @@ -885,7 +885,6 @@
885 885  
886 886  There is no AT Command for this feature.
887 887  
888 -
889 889  * Downlink Payload (prefix 0x AB 06):
890 890  
891 891  (% class="box infomessage" %)
... ... @@ -906,7 +906,6 @@
906 906  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
907 907  )))
908 908  
909 -
910 910  **Example:**
911 911  
912 912  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -935,12 +935,10 @@
935 935  
936 936  b : delay timing.
937 937  
938 -
939 939  **Example:**
940 940  
941 941  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
942 942  
943 -
944 944  * Downlink Payload (prefix 0x09 01 ):
945 945  
946 946  (% class="box infomessage" %)
... ... @@ -965,12 +965,10 @@
965 965  
966 966  b : delay timing.
967 967  
968 -
969 969  **Example:**
970 970  
971 971  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
972 972  
973 -
974 974  * Downlink Payload (prefix 0x09 02 ):
975 975  
976 976  (% class="box infomessage" %)
... ... @@ -991,7 +991,6 @@
991 991  **AT+ACLIM. **
992 992  )))
993 993  
994 -
995 995  * Downlink Payload (prefix 0xAA 01 ):
996 996  
997 997  (% class="box infomessage" %)
... ... @@ -1012,7 +1012,6 @@
1012 1012  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1013 1013  )))
1014 1014  
1015 -
1016 1016  * Downlink Payload (prefix 0xAA 00 ):
1017 1017  
1018 1018  (% class="box infomessage" %)
... ... @@ -1033,7 +1033,6 @@
1033 1033  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1034 1034  )))
1035 1035  
1036 -
1037 1037  * Downlink Payload (prefix 0xAC ):
1038 1038  
1039 1039  (% class="box infomessage" %)
... ... @@ -1049,7 +1049,6 @@
1049 1049  
1050 1050  There is no AT Command to control Digital Output
1051 1051  
1052 -
1053 1053  * Downlink Payload (prefix 0x02):
1054 1054  
1055 1055  (% class="box infomessage" %)
... ... @@ -1083,7 +1083,6 @@
1083 1083  
1084 1084  There is no AT Command to control Digital Output
1085 1085  
1086 -
1087 1087  * Downlink Payload (prefix 0xA9):
1088 1088  
1089 1089  (% class="box infomessage" %)
... ... @@ -1103,22 +1103,18 @@
1103 1103  
1104 1104  00: DO pins will change to an inverter state after timeout 
1105 1105  
1106 -
1107 1107  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1108 1108  
1109 1109  [[image:image-20220524093238-6.png]]
1110 1110  
1111 -
1112 1112  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1113 1113  
1114 1114  [[image:image-20220524093328-7.png]]
1115 1115  
1116 -
1117 1117  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1118 1118  
1119 1119  [[image:image-20220524093351-8.png]]
1120 1120  
1121 -
1122 1122  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1123 1123  
1124 1124   Latching time. Unit: ms
... ... @@ -1125,7 +1125,6 @@
1125 1125  
1126 1126  Device will upload a packet if downlink code executes successfully.
1127 1127  
1128 -
1129 1129  **Example payload:**
1130 1130  
1131 1131  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1146,13 +1146,12 @@
1146 1146  
1147 1147  
1148 1148  
1149 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1150 1150  
1151 1151  * AT Command:
1152 1152  
1153 1153  There is no AT Command to control Relay Output
1154 1154  
1155 -
1156 1156  * Downlink Payload (prefix 0x03):
1157 1157  
1158 1158  (% class="box infomessage" %)
... ... @@ -1182,7 +1182,6 @@
1182 1182  
1183 1183  There is no AT Command to control Relay Output
1184 1184  
1185 -
1186 1186  * Downlink Payload (prefix 0x05):
1187 1187  
1188 1188  (% class="box infomessage" %)
... ... @@ -1200,17 +1200,14 @@
1200 1200  
1201 1201  00: Relays will change to an inverter state after timeout
1202 1202  
1203 -
1204 1204  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1205 1205  
1206 1206  [[image:image-20220524093831-10.png]]
1207 1207  
1208 -
1209 1209  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1210 1210  
1211 1211  Device will upload a packet if downlink code executes successfully.
1212 1212  
1213 -
1214 1214  **Example payload:**
1215 1215  
1216 1216  **~1. 05 01 11 07 D0**
... ... @@ -1242,7 +1242,6 @@
1242 1242  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1243 1243  )))
1244 1244  
1245 -
1246 1246  * Downlink Payload (prefix 0xA5):
1247 1247  
1248 1248  (% class="box infomessage" %)
... ... @@ -1269,7 +1269,6 @@
1269 1269  
1270 1270  Bb cc dd ee: number to be set
1271 1271  
1272 -
1273 1273  * Downlink Payload (prefix 0xA8):
1274 1274  
1275 1275  (% class="box infomessage" %)
... ... @@ -1322,6 +1322,7 @@
1322 1322  )))
1323 1323  
1324 1324  
1257 +
1325 1325  == 3.5 Integrate with Mydevice ==
1326 1326  
1327 1327  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: