Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -276,6 +276,7 @@ 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 278 292 + 279 279 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 280 280 281 281 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -330,6 +330,7 @@ 330 330 ** DO1 LED is off in both case 331 331 332 332 347 + 333 333 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 334 334 335 335 ... ... @@ -366,12 +366,7 @@ 366 366 ((( 367 367 ((( 368 368 **AT+MOD=2** 369 -))) 370 -))) 371 371 372 -(% class="box infomessage" %) 373 -((( 374 -((( 375 375 **ATZ** 376 376 ))) 377 377 ))) ... ... @@ -390,40 +390,15 @@ 390 390 ((( 391 391 ((( 392 392 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 393 -))) 394 -))) 395 395 396 -(% class="box infomessage" %) 397 -((( 398 -((( 399 399 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 400 -))) 401 -))) 402 402 403 -(% class="box infomessage" %) 404 -((( 405 -((( 406 406 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 407 -))) 408 -))) 409 409 410 -(% class="box infomessage" %) 411 -((( 412 -((( 413 413 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 414 -))) 415 -))) 416 416 417 -(% class="box infomessage" %) 418 -((( 419 -((( 420 420 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 421 -))) 422 -))) 423 423 424 -(% class="box infomessage" %) 425 -((( 426 -((( 427 427 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 428 428 ))) 429 429 ))) ... ... @@ -458,12 +458,7 @@ 458 458 ((( 459 459 ((( 460 460 **AT+MOD=3** 461 -))) 462 -))) 463 463 464 -(% class="box infomessage" %) 465 -((( 466 -((( 467 467 **ATZ** 468 468 ))) 469 469 ))) ... ... @@ -470,11 +470,10 @@ 470 470 471 471 ((( 472 472 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 473 - 474 - 475 475 ))) 476 476 477 477 456 + 478 478 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 479 479 480 480 ... ... @@ -509,20 +509,13 @@ 509 509 ((( 510 510 ((( 511 511 **AT+MOD=4** 512 -))) 513 -))) 514 514 515 -(% class="box infomessage" %) 516 -((( 517 -((( 518 518 **ATZ** 519 519 ))) 520 520 ))) 521 521 522 -((( 523 - 524 -))) 525 525 497 + 526 526 ((( 527 527 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 528 528 ))) ... ... @@ -536,33 +536,17 @@ 536 536 (% class="box infomessage" %) 537 537 ((( 538 538 ((( 539 -**AT+SETCNT=3,60 (set AVI Count to 60)** 540 -))) 541 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 542 542 543 -(% class="box infomessage" %) 544 -((( 545 -((( 546 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 547 -))) 548 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 549 549 550 -(% class="box infomessage" %) 551 -((( 552 -((( 553 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 554 -))) 555 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 556 556 557 -(% class="box infomessage" %) 558 -((( 559 -((( 560 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 561 561 ))) 562 562 ))) 563 563 564 564 565 - 566 566 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 567 567 568 568 ... ... @@ -596,12 +596,7 @@ 596 596 ((( 597 597 ((( 598 598 **AT+MOD=5** 599 -))) 600 -))) 601 601 602 -(% class="box infomessage" %) 603 -((( 604 -((( 605 605 **ATZ** 606 606 ))) 607 607 ))) ... ... @@ -627,7 +627,7 @@ 627 627 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 628 628 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 629 629 630 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 631 631 632 632 (% style="color:#4f81bd" %)**Trigger base on voltage**: 633 633 ... ... @@ -640,6 +640,7 @@ 640 640 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 641 641 642 642 594 + 643 643 (% style="color:#4f81bd" %)**Trigger base on current**: 644 644 645 645 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -649,6 +649,7 @@ 649 649 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 650 650 651 651 604 + 652 652 (% style="color:#4f81bd" %)**Trigger base on DI status**: 653 653 654 654 DI status trigger Flag. ... ... @@ -661,7 +661,7 @@ 661 661 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 662 662 663 663 664 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 665 665 666 666 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 667 667 ... ... @@ -704,8 +704,6 @@ 704 704 705 705 * Each bits shows if the corresponding trigger has been configured. 706 706 707 - 708 - 709 709 **Example:** 710 710 711 711 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -717,8 +717,6 @@ 717 717 718 718 * Each bits shows which status has been trigger on this uplink. 719 719 720 - 721 - 722 722 **Example:** 723 723 724 724 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -730,8 +730,6 @@ 730 730 731 731 * Each bits shows which status has been trigger on this uplink. 732 732 733 - 734 - 735 735 **Example:** 736 736 737 737 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -760,7 +760,6 @@ 760 760 ))) 761 761 762 762 763 - 764 764 == 3.4 Configure LT via AT or Downlink == 765 765 766 766 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -787,7 +787,7 @@ 787 787 788 788 Set device uplink interval. 789 789 790 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 791 791 792 792 (% class="box infomessage" %) 793 793 ((( ... ... @@ -797,7 +797,7 @@ 797 797 **Example: **AT+TDC=30000. Means set interval to 30 seconds 798 798 799 799 800 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 801 801 802 802 (% class="box infomessage" %) 803 803 ((( ... ... @@ -810,7 +810,7 @@ 810 810 811 811 Set work mode. 812 812 813 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 814 814 815 815 (% class="box infomessage" %) 816 816 ((( ... ... @@ -820,7 +820,7 @@ 820 820 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 821 821 822 822 823 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 824 824 825 825 (% class="box infomessage" %) 826 826 ((( ... ... @@ -831,12 +831,12 @@ 831 831 832 832 ==== 3.4.2.3 Poll an uplink ==== 833 833 834 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 835 835 836 836 There is no AT Command to poll uplink 837 837 838 838 839 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 840 840 841 841 (% class="box infomessage" %) 842 842 ((( ... ... @@ -851,7 +851,7 @@ 851 851 852 852 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 853 853 854 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 855 855 856 856 (% class="box infomessage" %) 857 857 ((( ... ... @@ -863,7 +863,7 @@ 863 863 0: Disable Trigger Mode 864 864 865 865 866 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 867 867 868 868 (% class="box infomessage" %) 869 869 ((( ... ... @@ -876,12 +876,12 @@ 876 876 877 877 Poll trigger settings, 878 878 879 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 880 880 881 881 There is no AT Command for this feature. 882 882 883 883 884 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 885 885 886 886 (% class="box infomessage" %) 887 887 ((( ... ... @@ -894,7 +894,7 @@ 894 894 895 895 Enable Disable DI1/DI2/DI2 as trigger, 896 896 897 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 898 898 899 899 (% class="box infomessage" %) 900 900 ((( ... ... @@ -906,7 +906,7 @@ 906 906 907 907 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 908 908 909 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 910 910 911 911 (% class="box infomessage" %) 912 912 ((( ... ... @@ -919,7 +919,7 @@ 919 919 920 920 Set DI1 or DI3(for LT-33222-L) trigger. 921 921 922 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 923 923 924 924 (% class="box infomessage" %) 925 925 ((( ... ... @@ -936,7 +936,7 @@ 936 936 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 937 937 938 938 939 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 940 940 941 941 (% class="box infomessage" %) 942 942 ((( ... ... @@ -949,7 +949,7 @@ 949 949 950 950 Set DI2 trigger. 951 951 952 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 953 953 954 954 (% class="box infomessage" %) 955 955 ((( ... ... @@ -966,7 +966,7 @@ 966 966 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 967 967 968 968 969 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 970 970 971 971 (% class="box infomessage" %) 972 972 ((( ... ... @@ -979,7 +979,7 @@ 979 979 980 980 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 981 981 982 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 983 983 984 984 (% class="box infomessage" %) 985 985 ((( ... ... @@ -987,7 +987,7 @@ 987 987 ))) 988 988 989 989 990 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 991 991 992 992 (% class="box infomessage" %) 993 993 ((( ... ... @@ -1000,7 +1000,7 @@ 1000 1000 1001 1001 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1002 1002 1003 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 1004 1004 1005 1005 (% class="box infomessage" %) 1006 1006 ((( ... ... @@ -1008,7 +1008,7 @@ 1008 1008 ))) 1009 1009 1010 1010 1011 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 1012 1012 1013 1013 (% class="box infomessage" %) 1014 1014 ((( ... ... @@ -1021,7 +1021,7 @@ 1021 1021 1022 1022 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1023 1023 1024 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1025 1025 1026 1026 (% class="box infomessage" %) 1027 1027 ((( ... ... @@ -1029,7 +1029,7 @@ 1029 1029 ))) 1030 1030 1031 1031 1032 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC ):** 1033 1033 1034 1034 (% class="box infomessage" %) 1035 1035 ((( ... ... @@ -1040,17 +1040,14 @@ 1040 1040 1041 1041 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1042 1042 1043 -* AT Command: 989 +* (% style="color:#037691" %)**AT Command:** 1044 1044 1045 1045 There is no AT Command to control Digital Output 1046 1046 1047 1047 1048 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02):** 995 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1049 1049 1050 -(% class="box infomessage" %) 1051 -((( 1052 -**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1053 -))) 1054 1054 1055 1055 ((( 1056 1056 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1072,22 +1072,19 @@ 1072 1072 1073 1073 1074 1074 1018 + 1075 1075 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1076 1076 1077 -* AT Command: 1021 +* (% style="color:#037691" %)**AT Command:** 1078 1078 1079 1079 There is no AT Command to control Digital Output 1080 1080 1081 1081 1082 -* Downlink Payload (prefix 0xA9): 1026 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9):** 1083 1083 1084 -(% class="box infomessage" %) 1085 -((( 1086 -((( 1087 -**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1088 -))) 1089 -))) 1028 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1090 1090 1030 + 1091 1091 This is to control the digital output time of DO pin. Include four bytes: 1092 1092 1093 1093 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1141,20 +1141,19 @@ 1141 1141 1142 1142 1143 1143 1084 + 1144 1144 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1145 1145 1146 -* AT Command: 1087 +* (% style="color:#037691" %)**AT Command:** 1147 1147 1148 1148 There is no AT Command to control Relay Output 1149 1149 1150 1150 1151 -* Downlink Payload (prefix 0x03): 1092 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1152 1152 1153 -(% class="box infomessage" %) 1154 -((( 1155 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1156 -))) 1094 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1157 1157 1096 + 1158 1158 ((( 1159 1159 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1160 1160 ))) ... ... @@ -1171,20 +1171,19 @@ 1171 1171 1172 1172 1173 1173 1113 + 1174 1174 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1175 1175 1176 -* AT Command: 1116 +* (% style="color:#037691" %)**AT Command:** 1177 1177 1178 1178 There is no AT Command to control Relay Output 1179 1179 1180 1180 1181 -* Downlink Payload (prefix 0x05): 1121 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1182 1182 1183 -(% class="box infomessage" %) 1184 -((( 1185 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1186 -))) 1123 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1187 1187 1125 + 1188 1188 This is to control the relay output time of relay. Include four bytes: 1189 1189 1190 1190 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1226,35 +1226,28 @@ 1226 1226 1227 1227 1228 1228 1167 + 1229 1229 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1230 1230 1231 1231 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1232 1232 1233 -* AT Command: 1172 +* (% style="color:#037691" %)**AT Command:** 1234 1234 1235 -(% class="box infomessage" %) 1236 -((( 1237 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1238 -))) 1174 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1239 1239 1240 1240 1241 -* Downlink Payload (prefix 0xA5): 1177 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1242 1242 1243 -(% class="box infomessage" %) 1244 -((( 1245 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1246 -))) 1179 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1247 1247 1248 1248 1249 1249 1183 + 1250 1250 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1251 1251 1252 -* AT Command: 1186 +* (% style="color:#037691" %)**AT Command:** 1253 1253 1254 -(% class="box infomessage" %) 1255 -((( 1256 -**AT+SETCNT=aa,(bb cc dd ee) ** 1257 -))) 1188 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1258 1258 1259 1259 aa: 1: Set count1, 1260 1260 ... ... @@ -1265,51 +1265,40 @@ 1265 1265 Bb cc dd ee: number to be set 1266 1266 1267 1267 1268 -* Downlink Payload (prefix 0xA8): 1199 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1269 1269 1270 -(% class="box infomessage" %) 1271 -((( 1272 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1273 -))) 1201 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1274 1274 1275 1275 1276 1276 1205 + 1277 1277 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1278 1278 1279 1279 Clear counting for counting mode 1280 1280 1281 -* AT Command: 1210 +* (% style="color:#037691" %)**AT Command:** 1282 1282 1283 -(% class="box infomessage" %) 1284 -((( 1285 -**AT+CLRCOUNT ~/~/ clear all counting** 1286 -))) 1212 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1287 1287 1288 -* Downlink Payload (prefix 0xA6): 1289 1289 1290 -(% class="box infomessage" %) 1291 -((( 1292 -**0x A6 01 ~/~/ clear all counting,** 1293 -))) 1215 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1294 1294 1217 +**0x A6 01 ** ~/~/ clear all counting 1295 1295 1296 1296 1220 + 1221 + 1297 1297 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1298 1298 1299 -* AT Command: 1224 +* (% style="color:#037691" %)**AT Command:** 1300 1300 1301 -(% class="box infomessage" %) 1302 -((( 1303 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1304 -))) 1226 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1305 1305 1306 -* Downlink Payload (prefix 0xA7): 1307 1307 1308 -(% class="box infomessage" %) 1309 -((( 1310 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1311 -))) 1229 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1312 1312 1231 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1232 + 1313 1313 ((( 1314 1314 range: aa bb cc:0 to 16777215, (unit:second) 1315 1315 ... ... @@ -1317,6 +1317,7 @@ 1317 1317 ))) 1318 1318 1319 1319 1240 + 1320 1320 == 3.5 Integrate with Mydevice == 1321 1321 1322 1322 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -2006,8 +2006,16 @@ 2006 2006 ))) 2007 2007 2008 2008 ((( 2009 - 1930 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 2010 2010 1932 +If the device is not shut down, but directly powered off. 1933 + 1934 +It will default that this is a power-off state. 1935 + 1936 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1937 + 1938 +After restart, the status before power failure will be read from flash. 1939 + 2011 2011 = 6. Trouble Shooting = 2012 2012 ))) 2013 2013