276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 278  
279 +
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -314,6 +314,7 @@
314 314  * [1] RO1 relay channel is close and the RO1 LED is ON.
315 315  * [0] RO2 relay channel is open and RO2 LED is OFF;
316 316  
318 +
317 317  **LT22222-L:**
318 318  
319 319  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -330,6 +330,7 @@
330 330  ** DO1 LED is off in both case
331 331  
332 332  
335 +
333 333  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
334 334  
335 335  
... ... @@ -655,7 +655,6 @@
655 655  
656 656  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
657 657  
658 -
659 659  **Example:**
660 660  
661 661  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -685,7 +685,6 @@
685 685  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
686 686  
687 687  
688 -
689 689  **Example2**: AA 02 01 00
690 690  
691 691  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -704,8 +704,6 @@
704 704  
705 705  * Each bits shows if the corresponding trigger has been configured.
706 706  
707 -
708 -
709 709  **Example:**
710 710  
711 711  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -717,8 +717,6 @@
717 717  
718 718  * Each bits shows which status has been trigger on this uplink.
719 719  
720 -
721 -
722 722  **Example:**
723 723  
724 724  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -730,8 +730,6 @@
730 730  
731 731  * Each bits shows which status has been trigger on this uplink.
732 732  
733 -
734 -
735 735  **Example:**
736 736  
737 737  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -775,6 +775,7 @@
775 775  
776 776  
777 777  
773 +
778 778  === 3.4.1 Common Commands ===
779 779  
780 780  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]