Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,7 +275,6 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 - 279 279 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 280 280 281 281 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -283,8 +283,6 @@ 283 283 [[image:image-20220523174024-3.png]] 284 284 285 285 ((( 286 - 287 - 288 288 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 289 289 ))) 290 290 ... ... @@ -298,7 +298,6 @@ 298 298 299 299 For example if payload is: [[image:image-20220523175847-2.png]] 300 300 301 - 302 302 **The value for the interface is: ** 303 303 304 304 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -314,6 +314,7 @@ 314 314 * [1] RO1 relay channel is close and the RO1 LED is ON. 315 315 * [0] RO2 relay channel is open and RO2 LED is OFF; 316 316 313 + 317 317 **LT22222-L:** 318 318 319 319 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -655,7 +655,6 @@ 655 655 656 656 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 657 657 658 - 659 659 **Example:** 660 660 661 661 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -685,7 +685,6 @@ 685 685 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 686 686 687 687 688 - 689 689 **Example2**: AA 02 01 00 690 690 691 691 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -704,8 +704,6 @@ 704 704 705 705 * Each bits shows if the corresponding trigger has been configured. 706 706 707 - 708 - 709 709 **Example:** 710 710 711 711 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -717,8 +717,6 @@ 717 717 718 718 * Each bits shows which status has been trigger on this uplink. 719 719 720 - 721 - 722 722 **Example:** 723 723 724 724 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -730,8 +730,6 @@ 730 730 731 731 * Each bits shows which status has been trigger on this uplink. 732 732 733 - 734 - 735 735 **Example:** 736 736 737 737 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -774,7 +774,6 @@ 774 774 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 775 775 776 776 777 - 778 778 === 3.4.1 Common Commands === 779 779 780 780 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]