Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -314,6 +314,8 @@ 314 314 * [1] RO1 relay channel is close and the RO1 LED is ON. 315 315 * [0] RO2 relay channel is open and RO2 LED is OFF; 316 316 317 + 318 + 317 317 **LT22222-L:** 318 318 319 319 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -330,6 +330,7 @@ 330 330 ** DO1 LED is off in both case 331 331 332 332 335 + 333 333 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 334 334 335 335 ... ... @@ -622,11 +622,14 @@ 622 622 * **AT+MOD=1 ** **~-~->** The normal working mode 623 623 * **AT+ADDMOD6=1** **~-~->** Enable trigger 624 624 628 + 625 625 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 626 626 627 627 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 628 628 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 629 629 634 + 635 + 630 630 **AT Command to set Trigger Condition**: 631 631 632 632 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -640,6 +640,7 @@ 640 640 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 641 641 642 642 649 + 643 643 (% style="color:#4f81bd" %)**Trigger base on current**: 644 644 645 645 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -649,6 +649,7 @@ 649 649 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 650 650 651 651 659 + 652 652 (% style="color:#4f81bd" %)**Trigger base on DI status**: 653 653 654 654 DI status trigger Flag. ... ... @@ -655,12 +655,13 @@ 655 655 656 656 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 657 657 666 + 658 658 **Example:** 659 659 660 660 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 661 661 662 662 663 -**Downlink Command to set Trigger Condition** 672 +**Downlink Command to set Trigger Condition:** 664 664 665 665 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 666 666 ... ... @@ -689,6 +689,7 @@ 689 689 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 690 690 691 691 701 + 692 692 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 693 693 694 694 MOD6 Payload : total 11 bytes payload ... ... @@ -702,6 +702,8 @@ 702 702 703 703 * Each bits shows if the corresponding trigger has been configured. 704 704 715 + 716 + 705 705 **Example:** 706 706 707 707 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW