<
From version < 77.92 >
edited by Xiaoling
on 2022/06/10 09:29
To version < 77.86 >
edited by Xiaoling
on 2022/06/10 09:27
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -275,7 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 279  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
280 280  
281 281  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -283,8 +283,6 @@
283 283  [[image:image-20220523174024-3.png]]
284 284  
285 285  (((
286 -
287 -
288 288  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
289 289  )))
290 290  
... ... @@ -298,7 +298,6 @@
298 298  
299 299  For example if payload is: [[image:image-20220523175847-2.png]]
300 300  
301 -
302 302  **The value for the interface is:  **
303 303  
304 304  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -330,6 +330,7 @@
330 330  ** DO1 LED is off in both case
331 331  
332 332  
329 +
333 333  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
334 334  
335 335  
... ... @@ -622,11 +622,13 @@
622 622  * **AT+MOD=1 ** **~-~->** The normal working mode
623 623  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
624 624  
622 +
625 625  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
626 626  
627 627  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
628 628  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
629 629  
628 +
630 630  **AT Command to set Trigger Condition**:
631 631  
632 632  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -702,6 +702,7 @@
702 702  
703 703  * Each bits shows if the corresponding trigger has been configured.
704 704  
704 +
705 705  **Example:**
706 706  
707 707  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -714,7 +714,6 @@
714 714  * Each bits shows which status has been trigger on this uplink.
715 715  
716 716  
717 -
718 718  **Example:**
719 719  
720 720  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -727,7 +727,6 @@
727 727  * Each bits shows which status has been trigger on this uplink.
728 728  
729 729  
730 -
731 731  **Example:**
732 732  
733 733  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0