From version < 77.92 >
edited by Xiaoling
on 2022/06/10 09:29
To version < 77.113 >
edited by Xiaoling
on 2022/06/10 09:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -76,6 +76,8 @@
76 76  )))
77 77  
78 78  (((
79 +
80 +
79 79  **Interface for Model: LT22222-L:**
80 80  )))
81 81  
... ... @@ -99,6 +99,8 @@
99 99  )))
100 100  
101 101  (((
104 +
105 +
102 102  **LoRa Spec:**
103 103  )))
104 104  
... ... @@ -158,10 +158,10 @@
158 158  )))
159 159  * (((
160 160  Packet engine up to 256 bytes with CRC.
161 -
162 -
163 163  )))
164 164  
167 +
168 +
165 165  == 1.3 Features ==
166 166  
167 167  * LoRaWAN Class A & Class C protocol
... ... @@ -172,6 +172,8 @@
172 172  * Firmware upgradable via program port
173 173  * Counting
174 174  
179 +
180 +
175 175  == 1.4  Applications ==
176 176  
177 177  * Smart Buildings & Home Automation
... ... @@ -181,6 +181,8 @@
181 181  * Smart Cities
182 182  * Smart Factory
183 183  
190 +
191 +
184 184  == 1.5 Hardware Variants ==
185 185  
186 186  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -194,6 +194,7 @@
194 194  * 1 x Counting Port
195 195  )))
196 196  
205 +
197 197  = 2. Power ON Device =
198 198  
199 199  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -216,12 +216,9 @@
216 216  
217 217  (((
218 218  In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
219 -
220 -
221 221  )))
222 222  
223 223  
224 -
225 225  == 3.2 Example to join LoRaWAN network ==
226 226  
227 227  (((
... ... @@ -230,12 +230,13 @@
230 230  
231 231  [[image:image-20220523172350-1.png||height="266" width="864"]]
232 232  
239 +
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
235 235  )))
236 236  
237 237  (((
238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
245 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,6 +244,7 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
254 +
247 247  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
248 248  
249 249  Add APP EUI in the application.
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
268 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -640,6 +640,7 @@
640 640  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
641 641  
642 642  
651 +
643 643  (% style="color:#4f81bd" %)**Trigger base on current**:
644 644  
645 645  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -649,6 +649,7 @@
649 649  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
650 650  
651 651  
661 +
652 652  (% style="color:#4f81bd" %)**Trigger base on DI status**:
653 653  
654 654  DI status trigger Flag.
... ... @@ -655,12 +655,13 @@
655 655  
656 656  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
657 657  
668 +
658 658  **Example:**
659 659  
660 660  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
661 661  
662 662  
663 -**Downlink Command to set Trigger Condition**
674 +**Downlink Command to set Trigger Condition:**
664 664  
665 665  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
666 666  
... ... @@ -689,6 +689,7 @@
689 689  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
690 690  
691 691  
703 +
692 692  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
693 693  
694 694  MOD6 Payload : total 11 bytes payload
... ... @@ -713,8 +713,6 @@
713 713  
714 714  * Each bits shows which status has been trigger on this uplink.
715 715  
716 -
717 -
718 718  **Example:**
719 719  
720 720  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -726,8 +726,6 @@
726 726  
727 727  * Each bits shows which status has been trigger on this uplink.
728 728  
729 -
730 -
731 731  **Example:**
732 732  
733 733  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -769,8 +769,6 @@
769 769  
770 770  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
771 771  
772 -
773 -
774 774  === 3.4.1 Common Commands ===
775 775  
776 776  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0