Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -276,7 +276,6 @@ 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 278 279 - 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -316,6 +316,7 @@ 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 318 318 + 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -625,11 +625,14 @@ 625 625 * **AT+MOD=1 ** **~-~->** The normal working mode 626 626 * **AT+ADDMOD6=1** **~-~->** Enable trigger 627 627 628 + 628 628 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 629 629 630 630 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 631 631 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 632 632 634 + 635 + 633 633 **AT Command to set Trigger Condition**: 634 634 635 635 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -643,6 +643,7 @@ 643 643 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 644 644 645 645 649 + 646 646 (% style="color:#4f81bd" %)**Trigger base on current**: 647 647 648 648 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -652,6 +652,7 @@ 652 652 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 653 653 654 654 659 + 655 655 (% style="color:#4f81bd" %)**Trigger base on DI status**: 656 656 657 657 DI status trigger Flag. ... ... @@ -658,12 +658,13 @@ 658 658 659 659 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 660 660 666 + 661 661 **Example:** 662 662 663 663 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 664 664 665 665 666 -**Downlink Command to set Trigger Condition** 672 +**Downlink Command to set Trigger Condition:** 667 667 668 668 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 669 669 ... ... @@ -692,6 +692,7 @@ 692 692 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 693 693 694 694 701 + 695 695 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 696 696 697 697 MOD6 Payload : total 11 bytes payload ... ... @@ -705,6 +705,8 @@ 705 705 706 706 * Each bits shows if the corresponding trigger has been configured. 707 707 715 + 716 + 708 708 **Example:** 709 709 710 710 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -716,6 +716,8 @@ 716 716 717 717 * Each bits shows which status has been trigger on this uplink. 718 718 728 + 729 + 719 719 **Example:** 720 720 721 721 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -727,6 +727,8 @@ 727 727 728 728 * Each bits shows which status has been trigger on this uplink. 729 729 741 + 742 + 730 730 **Example:** 731 731 732 732 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -770,7 +770,6 @@ 770 770 771 771 772 772 773 - 774 774 === 3.4.1 Common Commands === 775 775 776 776 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]