Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -276,7 +276,6 @@ 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 278 279 - 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -315,7 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -332,7 +332,6 @@ 332 332 ** DO1 LED is off in both case 333 333 334 334 335 - 336 336 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 337 337 338 338 ... ... @@ -658,6 +658,7 @@ 658 658 659 659 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 660 660 658 + 661 661 **Example:** 662 662 663 663 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -687,6 +687,7 @@ 687 687 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 688 688 689 689 688 + 690 690 **Example2**: AA 02 01 00 691 691 692 692 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) ... ... @@ -705,6 +705,8 @@ 705 705 706 706 * Each bits shows if the corresponding trigger has been configured. 707 707 707 + 708 + 708 708 **Example:** 709 709 710 710 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -716,6 +716,8 @@ 716 716 717 717 * Each bits shows which status has been trigger on this uplink. 718 718 720 + 721 + 719 719 **Example:** 720 720 721 721 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -727,6 +727,8 @@ 727 727 728 728 * Each bits shows which status has been trigger on this uplink. 729 729 733 + 734 + 730 730 **Example:** 731 731 732 732 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -770,7 +770,6 @@ 770 770 771 771 772 772 773 - 774 774 === 3.4.1 Common Commands === 775 775 776 776 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]