Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,8 +275,6 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 - 279 - 280 280 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 281 281 282 282 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -284,8 +284,6 @@ 284 284 [[image:image-20220523174024-3.png]] 285 285 286 286 ((( 287 - 288 - 289 289 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 290 290 ))) 291 291 ... ... @@ -299,7 +299,6 @@ 299 299 300 300 For example if payload is: [[image:image-20220523175847-2.png]] 301 301 302 - 303 303 **The value for the interface is: ** 304 304 305 305 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -315,7 +315,6 @@ 315 315 * [1] RO1 relay channel is close and the RO1 LED is ON. 316 316 * [0] RO2 relay channel is open and RO2 LED is OFF; 317 317 318 - 319 319 **LT22222-L:** 320 320 321 321 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -331,8 +331,6 @@ 331 331 ** DO1 is high in case there is load between DO1 and V+. 332 332 ** DO1 LED is off in both case 333 333 334 - 335 - 336 336 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 337 337 338 338 ... ... @@ -625,11 +625,13 @@ 625 625 * **AT+MOD=1 ** **~-~->** The normal working mode 626 626 * **AT+ADDMOD6=1** **~-~->** Enable trigger 627 627 620 + 628 628 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 629 629 630 630 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 631 631 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 632 632 626 + 633 633 **AT Command to set Trigger Condition**: 634 634 635 635 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -705,6 +705,7 @@ 705 705 706 706 * Each bits shows if the corresponding trigger has been configured. 707 707 702 + 708 708 **Example:** 709 709 710 710 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -716,6 +716,7 @@ 716 716 717 717 * Each bits shows which status has been trigger on this uplink. 718 718 714 + 719 719 **Example:** 720 720 721 721 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -727,6 +727,7 @@ 727 727 728 728 * Each bits shows which status has been trigger on this uplink. 729 729 726 + 730 730 **Example:** 731 731 732 732 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -770,7 +770,6 @@ 770 770 771 771 772 772 773 - 774 774 === 3.4.1 Common Commands === 775 775 776 776 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]