Last modified by Mengting Qiu on 2025/06/04 18:42

From version 77.91
edited by Xiaoling
on 2022/06/10 09:29
Change comment: There is no comment for this version
To version 77.58
edited by Xiaoling
on 2022/06/10 09:11
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -275,8 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -284,8 +284,6 @@
284 284  [[image:image-20220523174024-3.png]]
285 285  
286 286  (((
287 -
288 -
289 289  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
290 290  )))
291 291  
... ... @@ -299,7 +299,6 @@
299 299  
300 300  For example if payload is: [[image:image-20220523175847-2.png]]
301 301  
302 -
303 303  **The value for the interface is:  **
304 304  
305 305  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -315,7 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 319  **LT22222-L:**
320 320  
321 321  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -331,11 +331,8 @@
331 331  ** DO1 is high in case there is load between DO1 and V+.
332 332  ** DO1 LED is off in both case
333 333  
334 -
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 -
339 339  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
340 340  
341 341  (((
... ... @@ -344,7 +344,6 @@
344 344  
345 345  [[image:image-20220523180452-3.png]]
346 346  
347 -
348 348  (((
349 349  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
350 350  )))
... ... @@ -360,8 +360,6 @@
360 360  )))
361 361  
362 362  (((
363 -
364 -
365 365  **To use counting mode, please run:**
366 366  )))
367 367  
... ... @@ -380,8 +380,6 @@
380 380  )))
381 381  
382 382  (((
383 -
384 -
385 385  (% style="color:#4f81bd" %)**AT Commands for counting:**
386 386  )))
387 387  
... ... @@ -478,9 +478,9 @@
478 478  )))
479 479  
480 480  
467 +
481 481  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
482 482  
483 -
484 484  **LT22222-L**: This mode the DI1 is used as a counting pin.
485 485  
486 486  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -487,7 +487,6 @@
487 487  
488 488  [[image:image-20220523181903-8.png]]
489 489  
490 -
491 491  (((
492 492  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
493 493  )))
... ... @@ -503,8 +503,6 @@
503 503  )))
504 504  
505 505  (((
506 -
507 -
508 508  **To use this mode, please run:**
509 509  )))
510 510  
... ... @@ -531,8 +531,6 @@
531 531  )))
532 532  
533 533  (((
534 -
535 -
536 536  **Plus below command for AVI1 Counting:**
537 537  )))
538 538  
... ... @@ -568,14 +568,11 @@
568 568  
569 569  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
570 570  
571 -
572 572  **LT22222-L**: This mode the DI1 is used as a counting pin.
573 573  
574 574  [[image:image-20220523182334-9.png]]
575 575  
576 576  (((
577 -
578 -
579 579  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
580 580  )))
581 581  
... ... @@ -590,8 +590,6 @@
590 590  )))
591 591  
592 592  (((
593 -
594 -
595 595  **To use this mode, please run:**
596 596  )))
597 597  
... ... @@ -611,6 +611,8 @@
611 611  
612 612  (((
613 613  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
614 614  )))
615 615  
616 616  
... ... @@ -617,7 +617,6 @@
617 617  
618 618  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
619 619  
620 -
621 621  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
622 622  
623 623  For example, if user has configured below commands:
... ... @@ -681,17 +681,14 @@
681 681  
682 682   Yy4 yy4: AC2 or AV2 high limit.
683 683  
684 -
685 685  **Example1**: AA 00 13 88 00 00 00 00 00 00
686 686  
687 687  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
688 688  
689 -
690 690  **Example2**: AA 02 01 00
691 691  
692 692  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
693 693  
694 -
695 695  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
696 696  
697 697  MOD6 Payload : total 11 bytes payload
... ... @@ -698,7 +698,6 @@
698 698  
699 699  [[image:image-20220524085923-1.png]]
700 700  
701 -
702 702  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
703 703  
704 704  [[image:image-20220524090106-2.png]]
... ... @@ -747,8 +747,6 @@
747 747  === 3.3.7 Payload Decoder ===
748 748  
749 749  (((
750 -
751 -
752 752  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
753 753  
754 754  
... ... @@ -768,9 +768,6 @@
768 768  
769 769  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
770 770  
771 -
772 -
773 -
774 774  === 3.4.1 Common Commands ===
775 775  
776 776  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -792,7 +792,6 @@
792 792  
793 793  **Example: **AT+TDC=30000. Means set interval to 30 seconds
794 794  
795 -
796 796  * Downlink Payload (prefix 0x01):
797 797  
798 798  (% class="box infomessage" %)
... ... @@ -815,7 +815,6 @@
815 815  
816 816  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
817 817  
818 -
819 819  * Downlink Payload (prefix 0x0A):
820 820  
821 821  (% class="box infomessage" %)
... ... @@ -831,7 +831,6 @@
831 831  
832 832  There is no AT Command to poll uplink
833 833  
834 -
835 835  * Downlink Payload (prefix 0x08):
836 836  
837 837  (% class="box infomessage" %)
... ... @@ -858,7 +858,6 @@
858 858  
859 859  0: Disable Trigger Mode
860 860  
861 -
862 862  * Downlink Payload (prefix 0x0A 06):
863 863  
864 864  (% class="box infomessage" %)
... ... @@ -876,7 +876,6 @@
876 876  
877 877  There is no AT Command for this feature.
878 878  
879 -
880 880  * Downlink Payload (prefix 0x AB 06):
881 881  
882 882  (% class="box infomessage" %)
... ... @@ -897,7 +897,6 @@
897 897  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
898 898  )))
899 899  
900 -
901 901  **Example:**
902 902  
903 903  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -926,12 +926,10 @@
926 926  
927 927  b : delay timing.
928 928  
929 -
930 930  **Example:**
931 931  
932 932  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
933 933  
934 -
935 935  * Downlink Payload (prefix 0x09 01 ):
936 936  
937 937  (% class="box infomessage" %)
... ... @@ -956,12 +956,10 @@
956 956  
957 957  b : delay timing.
958 958  
959 -
960 960  **Example:**
961 961  
962 962  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
963 963  
964 -
965 965  * Downlink Payload (prefix 0x09 02 ):
966 966  
967 967  (% class="box infomessage" %)
... ... @@ -982,7 +982,6 @@
982 982  **AT+ACLIM. **
983 983  )))
984 984  
985 -
986 986  * Downlink Payload (prefix 0xAA 01 ):
987 987  
988 988  (% class="box infomessage" %)
... ... @@ -1003,7 +1003,6 @@
1003 1003  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1004 1004  )))
1005 1005  
1006 -
1007 1007  * Downlink Payload (prefix 0xAA 00 ):
1008 1008  
1009 1009  (% class="box infomessage" %)
... ... @@ -1024,7 +1024,6 @@
1024 1024  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1025 1025  )))
1026 1026  
1027 -
1028 1028  * Downlink Payload (prefix 0xAC ):
1029 1029  
1030 1030  (% class="box infomessage" %)
... ... @@ -1040,7 +1040,6 @@
1040 1040  
1041 1041  There is no AT Command to control Digital Output
1042 1042  
1043 -
1044 1044  * Downlink Payload (prefix 0x02):
1045 1045  
1046 1046  (% class="box infomessage" %)
... ... @@ -1074,7 +1074,6 @@
1074 1074  
1075 1075  There is no AT Command to control Digital Output
1076 1076  
1077 -
1078 1078  * Downlink Payload (prefix 0xA9):
1079 1079  
1080 1080  (% class="box infomessage" %)
... ... @@ -1094,22 +1094,18 @@
1094 1094  
1095 1095  00: DO pins will change to an inverter state after timeout 
1096 1096  
1097 -
1098 1098  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1099 1099  
1100 1100  [[image:image-20220524093238-6.png]]
1101 1101  
1102 -
1103 1103  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1104 1104  
1105 1105  [[image:image-20220524093328-7.png]]
1106 1106  
1107 -
1108 1108  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1109 1109  
1110 1110  [[image:image-20220524093351-8.png]]
1111 1111  
1112 -
1113 1113  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1114 1114  
1115 1115   Latching time. Unit: ms
... ... @@ -1116,7 +1116,6 @@
1116 1116  
1117 1117  Device will upload a packet if downlink code executes successfully.
1118 1118  
1119 -
1120 1120  **Example payload:**
1121 1121  
1122 1122  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1137,13 +1137,12 @@
1137 1137  
1138 1138  
1139 1139  
1140 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1141 1141  
1142 1142  * AT Command:
1143 1143  
1144 1144  There is no AT Command to control Relay Output
1145 1145  
1146 -
1147 1147  * Downlink Payload (prefix 0x03):
1148 1148  
1149 1149  (% class="box infomessage" %)
... ... @@ -1173,7 +1173,6 @@
1173 1173  
1174 1174  There is no AT Command to control Relay Output
1175 1175  
1176 -
1177 1177  * Downlink Payload (prefix 0x05):
1178 1178  
1179 1179  (% class="box infomessage" %)
... ... @@ -1191,17 +1191,14 @@
1191 1191  
1192 1192  00: Relays will change to an inverter state after timeout
1193 1193  
1194 -
1195 1195  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1196 1196  
1197 1197  [[image:image-20220524093831-10.png]]
1198 1198  
1199 -
1200 1200  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1201 1201  
1202 1202  Device will upload a packet if downlink code executes successfully.
1203 1203  
1204 -
1205 1205  **Example payload:**
1206 1206  
1207 1207  **~1. 05 01 11 07 D0**
... ... @@ -1233,7 +1233,6 @@
1233 1233  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1234 1234  )))
1235 1235  
1236 -
1237 1237  * Downlink Payload (prefix 0xA5):
1238 1238  
1239 1239  (% class="box infomessage" %)
... ... @@ -1260,7 +1260,6 @@
1260 1260  
1261 1261  Bb cc dd ee: number to be set
1262 1262  
1263 -
1264 1264  * Downlink Payload (prefix 0xA8):
1265 1265  
1266 1266  (% class="box infomessage" %)
... ... @@ -1313,16 +1313,17 @@
1313 1313  )))
1314 1314  
1315 1315  
1257 +
1316 1316  == 3.5 Integrate with Mydevice ==
1317 1317  
1318 1318  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
1319 1319  
1320 1320  (((
1321 -(% style="color:blue" %)**Step 1**(%%): Be sure that your device is programmed and properly connected to the network at this time.
1263 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
1322 1322  )))
1323 1323  
1324 1324  (((
1325 -(% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1267 +**Step 2**: To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps:
1326 1326  )))
1327 1327  
1328 1328  [[image:1653356737703-362.png||height="232" width="732"]]
... ... @@ -1329,13 +1329,12 @@
1329 1329  
1330 1330  [[image:image-20220524094641-11.png||height="390" width="723"]]
1331 1331  
1332 -
1333 1333  [[image:image-20220524094641-12.png||height="402" width="718"]]
1334 1334  
1335 1335  
1336 -(% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices.
1277 +**Step 3**: Create an account or log in Mydevices.
1337 1337  
1338 -(% style="color:blue" %)**Step 4**(%%): Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1279 +**Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %)
1339 1339  
1340 1340  Search under The things network
1341 1341  
... ... @@ -1342,21 +1342,16 @@
1342 1342  [[image:1653356838789-523.png||height="337" width="740"]]
1343 1343  
1344 1344  
1345 -
1346 1346  After added, the sensor data arrive TTN, it will also arrive and show in Mydevices.
1347 1347  
1348 1348  [[image:image-20220524094909-1.png||height="335" width="729"]]
1349 1349  
1350 -
1351 1351  [[image:image-20220524094909-2.png||height="337" width="729"]]
1352 1352  
1353 -
1354 1354  [[image:image-20220524094909-3.png||height="338" width="727"]]
1355 1355  
1356 -
1357 1357  [[image:image-20220524094909-4.png||height="339" width="728"]](% style="display:none" %)
1358 1358  
1359 -
1360 1360  [[image:image-20220524094909-5.png||height="341" width="734"]]
1361 1361  
1362 1362