... ... @@ -235,7 +235,7 @@
235 235  )))
236 236  
237 237  (((
238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
238 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,6 +244,7 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
247 +
247 247  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
248 248  
249 249  Add APP EUI in the application.
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -276,7 +276,6 @@
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 278  
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -332,7 +332,6 @@
332 332  ** DO1 LED is off in both case
333 333  
334 334  
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 338  
... ... @@ -630,6 +630,7 @@
630 630  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
631 631  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
632 632  
632 +
633 633  **AT Command to set Trigger Condition**:
634 634  
635 635  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -643,6 +643,7 @@
643 643  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
644 644  
645 645  
646 +
646 646  (% style="color:#4f81bd" %)**Trigger base on current**:
647 647  
648 648  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -652,6 +652,7 @@
652 652  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
653 653  
654 654  
656 +
655 655  (% style="color:#4f81bd" %)**Trigger base on DI status**:
656 656  
657 657  DI status trigger Flag.
... ... @@ -658,12 +658,13 @@
658 658  
659 659  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
660 660  
663 +
661 661  **Example:**
662 662  
663 663  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
664 664  
665 665  
666 -**Downlink Command to set Trigger Condition**
669 +**Downlink Command to set Trigger Condition:**
667 667  
668 668  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
669 669  
... ... @@ -692,6 +692,7 @@
692 692  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
693 693  
694 694  
698 +
695 695  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
696 696  
697 697  MOD6 Payload : total 11 bytes payload
... ... @@ -705,6 +705,7 @@
705 705  
706 706  * Each bits shows if the corresponding trigger has been configured.
707 707  
712 +
708 708  **Example:**
709 709  
710 710  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -716,6 +716,7 @@
716 716  
717 717  * Each bits shows which status has been trigger on this uplink.
718 718  
724 +
719 719  **Example:**
720 720  
721 721  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -727,6 +727,7 @@
727 727  
728 728  * Each bits shows which status has been trigger on this uplink.
729 729  
736 +
730 730  **Example:**
731 731  
732 732  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -769,8 +769,6 @@
769 769  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
770 770  
771 771  
772 -
773 -
774 774  === 3.4.1 Common Commands ===
775 775  
776 776  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]