Last modified by Mengting Qiu on 2025/06/04 18:42

From version 77.90
edited by Xiaoling
on 2022/06/10 09:28
Change comment: There is no comment for this version
To version 77.62
edited by Xiaoling
on 2022/06/10 09:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -275,8 +275,6 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 -
279 -
280 280  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
281 281  
282 282  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -284,8 +284,6 @@
284 284  [[image:image-20220523174024-3.png]]
285 285  
286 286  (((
287 -
288 -
289 289  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
290 290  )))
291 291  
... ... @@ -299,7 +299,6 @@
299 299  
300 300  For example if payload is: [[image:image-20220523175847-2.png]]
301 301  
302 -
303 303  **The value for the interface is:  **
304 304  
305 305  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -315,7 +315,6 @@
315 315  * [1] RO1 relay channel is close and the RO1 LED is ON.
316 316  * [0] RO2 relay channel is open and RO2 LED is OFF;
317 317  
318 -
319 319  **LT22222-L:**
320 320  
321 321  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -331,11 +331,8 @@
331 331  ** DO1 is high in case there is load between DO1 and V+.
332 332  ** DO1 LED is off in both case
333 333  
334 -
335 -
336 336  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
337 337  
338 -
339 339  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
340 340  
341 341  (((
... ... @@ -344,7 +344,6 @@
344 344  
345 345  [[image:image-20220523180452-3.png]]
346 346  
347 -
348 348  (((
349 349  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
350 350  )))
... ... @@ -360,8 +360,6 @@
360 360  )))
361 361  
362 362  (((
363 -
364 -
365 365  **To use counting mode, please run:**
366 366  )))
367 367  
... ... @@ -380,8 +380,6 @@
380 380  )))
381 381  
382 382  (((
383 -
384 -
385 385  (% style="color:#4f81bd" %)**AT Commands for counting:**
386 386  )))
387 387  
... ... @@ -478,9 +478,9 @@
478 478  )))
479 479  
480 480  
467 +
481 481  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
482 482  
483 -
484 484  **LT22222-L**: This mode the DI1 is used as a counting pin.
485 485  
486 486  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -487,7 +487,6 @@
487 487  
488 488  [[image:image-20220523181903-8.png]]
489 489  
490 -
491 491  (((
492 492  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
493 493  )))
... ... @@ -503,8 +503,6 @@
503 503  )))
504 504  
505 505  (((
506 -
507 -
508 508  **To use this mode, please run:**
509 509  )))
510 510  
... ... @@ -531,8 +531,6 @@
531 531  )))
532 532  
533 533  (((
534 -
535 -
536 536  **Plus below command for AVI1 Counting:**
537 537  )))
538 538  
... ... @@ -568,14 +568,11 @@
568 568  
569 569  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
570 570  
571 -
572 572  **LT22222-L**: This mode the DI1 is used as a counting pin.
573 573  
574 574  [[image:image-20220523182334-9.png]]
575 575  
576 576  (((
577 -
578 -
579 579  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
580 580  )))
581 581  
... ... @@ -590,8 +590,6 @@
590 590  )))
591 591  
592 592  (((
593 -
594 -
595 595  **To use this mode, please run:**
596 596  )))
597 597  
... ... @@ -611,6 +611,8 @@
611 611  
612 612  (((
613 613  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
614 614  )))
615 615  
616 616  
... ... @@ -617,7 +617,6 @@
617 617  
618 618  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
619 619  
620 -
621 621  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
622 622  
623 623  For example, if user has configured below commands:
... ... @@ -681,17 +681,14 @@
681 681  
682 682   Yy4 yy4: AC2 or AV2 high limit.
683 683  
684 -
685 685  **Example1**: AA 00 13 88 00 00 00 00 00 00
686 686  
687 687  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
688 688  
689 -
690 690  **Example2**: AA 02 01 00
691 691  
692 692  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
693 693  
694 -
695 695  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
696 696  
697 697  MOD6 Payload : total 11 bytes payload
... ... @@ -698,7 +698,6 @@
698 698  
699 699  [[image:image-20220524085923-1.png]]
700 700  
701 -
702 702  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
703 703  
704 704  [[image:image-20220524090106-2.png]]
... ... @@ -747,8 +747,6 @@
747 747  === 3.3.7 Payload Decoder ===
748 748  
749 749  (((
750 -
751 -
752 752  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
753 753  
754 754  
... ... @@ -768,7 +768,6 @@
768 768  
769 769  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
770 770  
771 -
772 772  === 3.4.1 Common Commands ===
773 773  
774 774  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -790,7 +790,6 @@
790 790  
791 791  **Example: **AT+TDC=30000. Means set interval to 30 seconds
792 792  
793 -
794 794  * Downlink Payload (prefix 0x01):
795 795  
796 796  (% class="box infomessage" %)
... ... @@ -813,7 +813,6 @@
813 813  
814 814  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
815 815  
816 -
817 817  * Downlink Payload (prefix 0x0A):
818 818  
819 819  (% class="box infomessage" %)
... ... @@ -829,7 +829,6 @@
829 829  
830 830  There is no AT Command to poll uplink
831 831  
832 -
833 833  * Downlink Payload (prefix 0x08):
834 834  
835 835  (% class="box infomessage" %)
... ... @@ -856,7 +856,6 @@
856 856  
857 857  0: Disable Trigger Mode
858 858  
859 -
860 860  * Downlink Payload (prefix 0x0A 06):
861 861  
862 862  (% class="box infomessage" %)
... ... @@ -874,7 +874,6 @@
874 874  
875 875  There is no AT Command for this feature.
876 876  
877 -
878 878  * Downlink Payload (prefix 0x AB 06):
879 879  
880 880  (% class="box infomessage" %)
... ... @@ -895,7 +895,6 @@
895 895  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
896 896  )))
897 897  
898 -
899 899  **Example:**
900 900  
901 901  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -924,12 +924,10 @@
924 924  
925 925  b : delay timing.
926 926  
927 -
928 928  **Example:**
929 929  
930 930  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
931 931  
932 -
933 933  * Downlink Payload (prefix 0x09 01 ):
934 934  
935 935  (% class="box infomessage" %)
... ... @@ -954,12 +954,10 @@
954 954  
955 955  b : delay timing.
956 956  
957 -
958 958  **Example:**
959 959  
960 960  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
961 961  
962 -
963 963  * Downlink Payload (prefix 0x09 02 ):
964 964  
965 965  (% class="box infomessage" %)
... ... @@ -980,7 +980,6 @@
980 980  **AT+ACLIM. **
981 981  )))
982 982  
983 -
984 984  * Downlink Payload (prefix 0xAA 01 ):
985 985  
986 986  (% class="box infomessage" %)
... ... @@ -1001,7 +1001,6 @@
1001 1001  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
1002 1002  )))
1003 1003  
1004 -
1005 1005  * Downlink Payload (prefix 0xAA 00 ):
1006 1006  
1007 1007  (% class="box infomessage" %)
... ... @@ -1022,7 +1022,6 @@
1022 1022  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1023 1023  )))
1024 1024  
1025 -
1026 1026  * Downlink Payload (prefix 0xAC ):
1027 1027  
1028 1028  (% class="box infomessage" %)
... ... @@ -1038,7 +1038,6 @@
1038 1038  
1039 1039  There is no AT Command to control Digital Output
1040 1040  
1041 -
1042 1042  * Downlink Payload (prefix 0x02):
1043 1043  
1044 1044  (% class="box infomessage" %)
... ... @@ -1072,7 +1072,6 @@
1072 1072  
1073 1073  There is no AT Command to control Digital Output
1074 1074  
1075 -
1076 1076  * Downlink Payload (prefix 0xA9):
1077 1077  
1078 1078  (% class="box infomessage" %)
... ... @@ -1092,22 +1092,18 @@
1092 1092  
1093 1093  00: DO pins will change to an inverter state after timeout 
1094 1094  
1095 -
1096 1096  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1097 1097  
1098 1098  [[image:image-20220524093238-6.png]]
1099 1099  
1100 -
1101 1101  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1102 1102  
1103 1103  [[image:image-20220524093328-7.png]]
1104 1104  
1105 -
1106 1106  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1107 1107  
1108 1108  [[image:image-20220524093351-8.png]]
1109 1109  
1110 -
1111 1111  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1112 1112  
1113 1113   Latching time. Unit: ms
... ... @@ -1114,7 +1114,6 @@
1114 1114  
1115 1115  Device will upload a packet if downlink code executes successfully.
1116 1116  
1117 -
1118 1118  **Example payload:**
1119 1119  
1120 1120  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1135,13 +1135,12 @@
1135 1135  
1136 1136  
1137 1137  
1138 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1139 1139  
1140 1140  * AT Command:
1141 1141  
1142 1142  There is no AT Command to control Relay Output
1143 1143  
1144 -
1145 1145  * Downlink Payload (prefix 0x03):
1146 1146  
1147 1147  (% class="box infomessage" %)
... ... @@ -1171,7 +1171,6 @@
1171 1171  
1172 1172  There is no AT Command to control Relay Output
1173 1173  
1174 -
1175 1175  * Downlink Payload (prefix 0x05):
1176 1176  
1177 1177  (% class="box infomessage" %)
... ... @@ -1189,12 +1189,10 @@
1189 1189  
1190 1190  00: Relays will change to an inverter state after timeout
1191 1191  
1192 -
1193 1193  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1194 1194  
1195 1195  [[image:image-20220524093831-10.png]]
1196 1196  
1197 -
1198 1198  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1199 1199  
1200 1200  Device will upload a packet if downlink code executes successfully.
... ... @@ -1231,7 +1231,6 @@
1231 1231  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1232 1232  )))
1233 1233  
1234 -
1235 1235  * Downlink Payload (prefix 0xA5):
1236 1236  
1237 1237  (% class="box infomessage" %)
... ... @@ -1258,7 +1258,6 @@
1258 1258  
1259 1259  Bb cc dd ee: number to be set
1260 1260  
1261 -
1262 1262  * Downlink Payload (prefix 0xA8):
1263 1263  
1264 1264  (% class="box infomessage" %)