Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,6 +275,7 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 286 + 287 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -311,7 +311,6 @@ 311 311 * [1] RO1 relay channel is close and the RO1 LED is ON. 312 312 * [0] RO2 relay channel is open and RO2 LED is OFF; 313 313 314 - 315 315 **LT22222-L:** 316 316 317 317 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -328,7 +328,6 @@ 328 328 ** DO1 LED is off in both case 329 329 330 330 331 - 332 332 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 333 333 334 334 ... ... @@ -621,11 +621,14 @@ 621 621 * **AT+MOD=1 ** **~-~->** The normal working mode 622 622 * **AT+ADDMOD6=1** **~-~->** Enable trigger 623 623 625 + 624 624 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 625 625 626 626 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 627 627 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 628 628 631 + 632 + 629 629 **AT Command to set Trigger Condition**: 630 630 631 631 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -639,6 +639,7 @@ 639 639 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 640 640 641 641 646 + 642 642 (% style="color:#4f81bd" %)**Trigger base on current**: 643 643 644 644 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -648,6 +648,7 @@ 648 648 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 649 649 650 650 656 + 651 651 (% style="color:#4f81bd" %)**Trigger base on DI status**: 652 652 653 653 DI status trigger Flag. ... ... @@ -654,12 +654,13 @@ 654 654 655 655 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 656 656 663 + 657 657 **Example:** 658 658 659 659 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 660 660 661 661 662 -**Downlink Command to set Trigger Condition** 669 +**Downlink Command to set Trigger Condition:** 663 663 664 664 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 665 665 ... ... @@ -688,6 +688,7 @@ 688 688 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 689 689 690 690 698 + 691 691 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 692 692 693 693 MOD6 Payload : total 11 bytes payload ... ... @@ -701,6 +701,8 @@ 701 701 702 702 * Each bits shows if the corresponding trigger has been configured. 703 703 712 + 713 + 704 704 **Example:** 705 705 706 706 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -712,6 +712,8 @@ 712 712 713 713 * Each bits shows which status has been trigger on this uplink. 714 714 725 + 726 + 715 715 **Example:** 716 716 717 717 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -723,6 +723,8 @@ 723 723 724 724 * Each bits shows which status has been trigger on this uplink. 725 725 738 + 739 + 726 726 **Example:** 727 727 728 728 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -765,6 +765,7 @@ 765 765 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 766 766 767 767 782 + 768 768 === 3.4.1 Common Commands === 769 769 770 770 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]