... ... @@ -275,6 +275,7 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
286 +
287 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -311,7 +311,6 @@
311 311  * [1] RO1 relay channel is close and the RO1 LED is ON.
312 312  * [0] RO2 relay channel is open and RO2 LED is OFF;
313 313  
314 -
315 315  **LT22222-L:**
316 316  
317 317  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -328,7 +328,6 @@
328 328  ** DO1 LED is off in both case
329 329  
330 330  
331 -
332 332  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
333 333  
334 334  
... ... @@ -654,6 +654,7 @@
654 654  
655 655  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
656 656  
658 +
657 657  **Example:**
658 658  
659 659  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -683,6 +683,7 @@
683 683  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
684 684  
685 685  
688 +
686 686  **Example2**: AA 02 01 00
687 687  
688 688  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -701,6 +701,8 @@
701 701  
702 702  * Each bits shows if the corresponding trigger has been configured.
703 703  
707 +
708 +
704 704  **Example:**
705 705  
706 706  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -712,6 +712,8 @@
712 712  
713 713  * Each bits shows which status has been trigger on this uplink.
714 714  
720 +
721 +
715 715  **Example:**
716 716  
717 717  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -723,6 +723,8 @@
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
733 +
734 +
726 726  **Example:**
727 727  
728 728  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -765,6 +765,7 @@
765 765  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
766 766  
767 767  
777 +
768 768  === 3.4.1 Common Commands ===
769 769  
770 770  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]