... ... @@ -295,7 +295,6 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
298 -
299 299  **The value for the interface is:  **
300 300  
301 301  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -311,7 +311,6 @@
311 311  * [1] RO1 relay channel is close and the RO1 LED is ON.
312 312  * [0] RO2 relay channel is open and RO2 LED is OFF;
313 313  
314 -
315 315  **LT22222-L:**
316 316  
317 317  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -621,11 +621,13 @@
621 621  * **AT+MOD=1 ** **~-~->** The normal working mode
622 622  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
623 623  
622 +
624 624  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
625 625  
626 626  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
627 627  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
628 628  
628 +
629 629  **AT Command to set Trigger Condition**:
630 630  
631 631  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -701,6 +701,7 @@
701 701  
702 702  * Each bits shows if the corresponding trigger has been configured.
703 703  
704 +
704 704  **Example:**
705 705  
706 706  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -712,6 +712,7 @@
712 712  
713 713  * Each bits shows which status has been trigger on this uplink.
714 714  
716 +
715 715  **Example:**
716 716  
717 717  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -723,6 +723,7 @@
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
728 +
726 726  **Example:**
727 727  
728 728  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -765,6 +765,7 @@
765 765  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
766 766  
767 767  
771 +
768 768  === 3.4.1 Common Commands ===
769 769  
770 770  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]