... ... @@ -295,7 +295,6 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
298 -
299 299  **The value for the interface is:  **
300 300  
301 301  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -311,7 +311,6 @@
311 311  * [1] RO1 relay channel is close and the RO1 LED is ON.
312 312  * [0] RO2 relay channel is open and RO2 LED is OFF;
313 313  
314 -
315 315  **LT22222-L:**
316 316  
317 317  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -327,11 +327,8 @@
327 327  ** DO1 is high in case there is load between DO1 and V+.
328 328  ** DO1 LED is off in both case
329 329  
330 -
331 -
332 332  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
333 333  
334 -
335 335  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
336 336  
337 337  (((
... ... @@ -340,7 +340,6 @@
340 340  
341 341  [[image:image-20220523180452-3.png]]
342 342  
343 -
344 344  (((
345 345  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
346 346  )))
... ... @@ -356,8 +356,6 @@
356 356  )))
357 357  
358 358  (((
359 -
360 -
361 361  **To use counting mode, please run:**
362 362  )))
363 363  
... ... @@ -376,8 +376,6 @@
376 376  )))
377 377  
378 378  (((
379 -
380 -
381 381  (% style="color:#4f81bd" %)**AT Commands for counting:**
382 382  )))
383 383  
... ... @@ -474,9 +474,9 @@
474 474  )))
475 475  
476 476  
467 +
477 477  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
478 478  
479 -
480 480  **LT22222-L**: This mode the DI1 is used as a counting pin.
481 481  
482 482  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -483,7 +483,6 @@
483 483  
484 484  [[image:image-20220523181903-8.png]]
485 485  
486 -
487 487  (((
488 488  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
489 489  )))
... ... @@ -613,7 +613,6 @@
613 613  
614 614  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
615 615  
616 -
617 617  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
618 618  
619 619  For example, if user has configured below commands:
... ... @@ -621,11 +621,13 @@
621 621  * **AT+MOD=1 ** **~-~->** The normal working mode
622 622  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
623 623  
612 +
624 624  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
625 625  
626 626  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
627 627  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
628 628  
618 +
629 629  **AT Command to set Trigger Condition**:
630 630  
631 631  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -701,6 +701,7 @@
701 701  
702 702  * Each bits shows if the corresponding trigger has been configured.
703 703  
694 +
704 704  **Example:**
705 705  
706 706  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -712,6 +712,7 @@
712 712  
713 713  * Each bits shows which status has been trigger on this uplink.
714 714  
706 +
715 715  **Example:**
716 716  
717 717  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -723,6 +723,7 @@
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
718 +
726 726  **Example:**
727 727  
728 728  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -743,8 +743,6 @@
743 743  === 3.3.7 Payload Decoder ===
744 744  
745 745  (((
746 -
747 -
748 748  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
749 749  
750 750  
... ... @@ -765,6 +765,7 @@
765 765  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
766 766  
767 767  
759 +
768 768  === 3.4.1 Common Commands ===
769 769  
770 770  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]