... ... @@ -275,6 +275,7 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
286 +
287 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -295,6 +295,7 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
301 +
298 298  **The value for the interface is:  **
299 299  
300 300  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -310,7 +310,6 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 -
314 314  **LT22222-L:**
315 315  
316 316  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -327,7 +327,6 @@
327 327  ** DO1 LED is off in both case
328 328  
329 329  
330 -
331 331  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
332 332  
333 333  
... ... @@ -653,6 +653,7 @@
653 653  
654 654  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
655 655  
658 +
656 656  **Example:**
657 657  
658 658  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -682,6 +682,7 @@
682 682  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
683 683  
684 684  
688 +
685 685  **Example2**: AA 02 01 00
686 686  
687 687  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -700,6 +700,8 @@
700 700  
701 701  * Each bits shows if the corresponding trigger has been configured.
702 702  
707 +
708 +
703 703  **Example:**
704 704  
705 705  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -711,6 +711,8 @@
711 711  
712 712  * Each bits shows which status has been trigger on this uplink.
713 713  
720 +
721 +
714 714  **Example:**
715 715  
716 716  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -722,6 +722,8 @@
722 722  
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
733 +
734 +
725 725  **Example:**
726 726  
727 727  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -764,6 +764,7 @@
764 764  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
765 765  
766 766  
777 +
767 767  === 3.4.1 Common Commands ===
768 768  
769 769  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]