Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -310,7 +310,6 @@ 310 310 * [1] RO1 relay channel is close and the RO1 LED is ON. 311 311 * [0] RO2 relay channel is open and RO2 LED is OFF; 312 312 313 - 314 314 **LT22222-L:** 315 315 316 316 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -326,11 +326,8 @@ 326 326 ** DO1 is high in case there is load between DO1 and V+. 327 327 ** DO1 LED is off in both case 328 328 329 - 330 - 331 331 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 332 332 333 - 334 334 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 335 335 336 336 ((( ... ... @@ -339,7 +339,6 @@ 339 339 340 340 [[image:image-20220523180452-3.png]] 341 341 342 - 343 343 ((( 344 344 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 345 345 ))) ... ... @@ -620,11 +620,13 @@ 620 620 * **AT+MOD=1 ** **~-~->** The normal working mode 621 621 * **AT+ADDMOD6=1** **~-~->** Enable trigger 622 622 618 + 623 623 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 624 624 625 625 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 626 626 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 627 627 624 + 628 628 **AT Command to set Trigger Condition**: 629 629 630 630 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -700,6 +700,7 @@ 700 700 701 701 * Each bits shows if the corresponding trigger has been configured. 702 702 700 + 703 703 **Example:** 704 704 705 705 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -711,6 +711,7 @@ 711 711 712 712 * Each bits shows which status has been trigger on this uplink. 713 713 712 + 714 714 **Example:** 715 715 716 716 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -722,6 +722,7 @@ 722 722 723 723 * Each bits shows which status has been trigger on this uplink. 724 724 724 + 725 725 **Example:** 726 726 727 727 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -764,6 +764,7 @@ 764 764 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 765 765 766 766 767 + 767 767 === 3.4.1 Common Commands === 768 768 769 769 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]