From version < 77.88 >
edited by Xiaoling
on 2022/06/10 09:27
To version < 77.80 >
edited by Xiaoling
on 2022/06/10 09:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -310,7 +310,6 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 -
314 314  **LT22222-L:**
315 315  
316 316  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -326,11 +326,8 @@
326 326  ** DO1 is high in case there is load between DO1 and V+.
327 327  ** DO1 LED is off in both case
328 328  
329 -
330 -
331 331  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
332 332  
333 -
334 334  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
335 335  
336 336  (((
... ... @@ -339,7 +339,6 @@
339 339  
340 340  [[image:image-20220523180452-3.png]]
341 341  
342 -
343 343  (((
344 344  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
345 345  )))
... ... @@ -355,8 +355,6 @@
355 355  )))
356 356  
357 357  (((
358 -
359 -
360 360  **To use counting mode, please run:**
361 361  )))
362 362  
... ... @@ -375,8 +375,6 @@
375 375  )))
376 376  
377 377  (((
378 -
379 -
380 380  (% style="color:#4f81bd" %)**AT Commands for counting:**
381 381  )))
382 382  
... ... @@ -473,9 +473,9 @@
473 473  )))
474 474  
475 475  
467 +
476 476  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
477 477  
478 -
479 479  **LT22222-L**: This mode the DI1 is used as a counting pin.
480 480  
481 481  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -482,7 +482,6 @@
482 482  
483 483  [[image:image-20220523181903-8.png]]
484 484  
485 -
486 486  (((
487 487  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
488 488  )))
... ... @@ -563,7 +563,6 @@
563 563  
564 564  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
565 565  
566 -
567 567  **LT22222-L**: This mode the DI1 is used as a counting pin.
568 568  
569 569  [[image:image-20220523182334-9.png]]
... ... @@ -612,7 +612,6 @@
612 612  
613 613  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
614 614  
615 -
616 616  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
617 617  
618 618  For example, if user has configured below commands:
... ... @@ -620,11 +620,13 @@
620 620  * **AT+MOD=1 ** **~-~->** The normal working mode
621 621  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
622 622  
611 +
623 623  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
624 624  
625 625  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
626 626  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
627 627  
617 +
628 628  **AT Command to set Trigger Condition**:
629 629  
630 630  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -700,6 +700,7 @@
700 700  
701 701  * Each bits shows if the corresponding trigger has been configured.
702 702  
693 +
703 703  **Example:**
704 704  
705 705  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -711,6 +711,7 @@
711 711  
712 712  * Each bits shows which status has been trigger on this uplink.
713 713  
705 +
714 714  **Example:**
715 715  
716 716  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -722,6 +722,7 @@
722 722  
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
717 +
725 725  **Example:**
726 726  
727 727  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -742,8 +742,6 @@
742 742  === 3.3.7 Payload Decoder ===
743 743  
744 744  (((
745 -
746 -
747 747  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
748 748  
749 749  
... ... @@ -764,6 +764,7 @@
764 764  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
765 765  
766 766  
758 +
767 767  === 3.4.1 Common Commands ===
768 768  
769 769  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0