<
From version < 77.88 >
edited by Xiaoling
on 2022/06/10 09:27
To version < 77.100 >
edited by Xiaoling
on 2022/06/10 09:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -235,7 +235,7 @@
235 235  )))
236 236  
237 237  (((
238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
238 +**(% style="color:blue" %)Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
260 +**(% style="color:blue" %)Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -275,6 +275,8 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 +
279 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
287 +
288 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -295,6 +295,7 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
302 +
298 298  **The value for the interface is:  **
299 299  
300 300  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -311,6 +311,7 @@
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 313  
319 +
314 314  **LT22222-L:**
315 315  
316 316  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -620,11 +620,14 @@
620 620  * **AT+MOD=1 ** **~-~->** The normal working mode
621 621  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
622 622  
629 +
623 623  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
624 624  
625 625  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
626 626  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
627 627  
635 +
636 +
628 628  **AT Command to set Trigger Condition**:
629 629  
630 630  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -638,6 +638,7 @@
638 638  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
639 639  
640 640  
650 +
641 641  (% style="color:#4f81bd" %)**Trigger base on current**:
642 642  
643 643  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -647,6 +647,7 @@
647 647  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
648 648  
649 649  
660 +
650 650  (% style="color:#4f81bd" %)**Trigger base on DI status**:
651 651  
652 652  DI status trigger Flag.
... ... @@ -653,12 +653,13 @@
653 653  
654 654  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
655 655  
667 +
656 656  **Example:**
657 657  
658 658  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
659 659  
660 660  
661 -**Downlink Command to set Trigger Condition**
673 +**Downlink Command to set Trigger Condition:**
662 662  
663 663  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
664 664  
... ... @@ -687,6 +687,7 @@
687 687  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
688 688  
689 689  
702 +
690 690  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
691 691  
692 692  MOD6 Payload : total 11 bytes payload
... ... @@ -700,6 +700,8 @@
700 700  
701 701  * Each bits shows if the corresponding trigger has been configured.
702 702  
716 +
717 +
703 703  **Example:**
704 704  
705 705  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -711,6 +711,8 @@
711 711  
712 712  * Each bits shows which status has been trigger on this uplink.
713 713  
729 +
730 +
714 714  **Example:**
715 715  
716 716  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -722,6 +722,8 @@
722 722  
723 723  * Each bits shows which status has been trigger on this uplink.
724 724  
742 +
743 +
725 725  **Example:**
726 726  
727 727  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -764,6 +764,7 @@
764 764  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
765 765  
766 766  
786 +
767 767  === 3.4.1 Common Commands ===
768 768  
769 769  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0