Last modified by Mengting Qiu on 2025/06/04 18:42

From version 77.87
edited by Xiaoling
on 2022/06/10 09:27
Change comment: There is no comment for this version
To version 77.63
edited by Xiaoling
on 2022/06/10 09:15
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -310,7 +310,6 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 -
314 314  **LT22222-L:**
315 315  
316 316  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -326,10 +326,8 @@
326 326  ** DO1 is high in case there is load between DO1 and V+.
327 327  ** DO1 LED is off in both case
328 328  
329 -
330 330  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
331 331  
332 -
333 333  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
334 334  
335 335  (((
... ... @@ -338,7 +338,6 @@
338 338  
339 339  [[image:image-20220523180452-3.png]]
340 340  
341 -
342 342  (((
343 343  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
344 344  )))
... ... @@ -354,8 +354,6 @@
354 354  )))
355 355  
356 356  (((
357 -
358 -
359 359  **To use counting mode, please run:**
360 360  )))
361 361  
... ... @@ -374,8 +374,6 @@
374 374  )))
375 375  
376 376  (((
377 -
378 -
379 379  (% style="color:#4f81bd" %)**AT Commands for counting:**
380 380  )))
381 381  
... ... @@ -472,9 +472,9 @@
472 472  )))
473 473  
474 474  
467 +
475 475  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
476 476  
477 -
478 478  **LT22222-L**: This mode the DI1 is used as a counting pin.
479 479  
480 480  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -481,7 +481,6 @@
481 481  
482 482  [[image:image-20220523181903-8.png]]
483 483  
484 -
485 485  (((
486 486  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
487 487  )))
... ... @@ -497,8 +497,6 @@
497 497  )))
498 498  
499 499  (((
500 -
501 -
502 502  **To use this mode, please run:**
503 503  )))
504 504  
... ... @@ -525,8 +525,6 @@
525 525  )))
526 526  
527 527  (((
528 -
529 -
530 530  **Plus below command for AVI1 Counting:**
531 531  )))
532 532  
... ... @@ -562,14 +562,11 @@
562 562  
563 563  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
564 564  
565 -
566 566  **LT22222-L**: This mode the DI1 is used as a counting pin.
567 567  
568 568  [[image:image-20220523182334-9.png]]
569 569  
570 570  (((
571 -
572 -
573 573  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
574 574  )))
575 575  
... ... @@ -584,8 +584,6 @@
584 584  )))
585 585  
586 586  (((
587 -
588 -
589 589  **To use this mode, please run:**
590 590  )))
591 591  
... ... @@ -605,6 +605,8 @@
605 605  
606 606  (((
607 607  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
608 608  )))
609 609  
610 610  
... ... @@ -611,7 +611,6 @@
611 611  
612 612  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
613 613  
614 -
615 615  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
616 616  
617 617  For example, if user has configured below commands:
... ... @@ -675,17 +675,14 @@
675 675  
676 676   Yy4 yy4: AC2 or AV2 high limit.
677 677  
678 -
679 679  **Example1**: AA 00 13 88 00 00 00 00 00 00
680 680  
681 681  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
682 682  
683 -
684 684  **Example2**: AA 02 01 00
685 685  
686 686  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
687 687  
688 -
689 689  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
690 690  
691 691  MOD6 Payload : total 11 bytes payload
... ... @@ -692,7 +692,6 @@
692 692  
693 693  [[image:image-20220524085923-1.png]]
694 694  
695 -
696 696  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
697 697  
698 698  [[image:image-20220524090106-2.png]]
... ... @@ -741,8 +741,6 @@
741 741  === 3.3.7 Payload Decoder ===
742 742  
743 743  (((
744 -
745 -
746 746  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
747 747  
748 748  
... ... @@ -762,7 +762,6 @@
762 762  
763 763  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
764 764  
765 -
766 766  === 3.4.1 Common Commands ===
767 767  
768 768  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -784,7 +784,6 @@
784 784  
785 785  **Example: **AT+TDC=30000. Means set interval to 30 seconds
786 786  
787 -
788 788  * Downlink Payload (prefix 0x01):
789 789  
790 790  (% class="box infomessage" %)
... ... @@ -807,7 +807,6 @@
807 807  
808 808  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
809 809  
810 -
811 811  * Downlink Payload (prefix 0x0A):
812 812  
813 813  (% class="box infomessage" %)
... ... @@ -823,7 +823,6 @@
823 823  
824 824  There is no AT Command to poll uplink
825 825  
826 -
827 827  * Downlink Payload (prefix 0x08):
828 828  
829 829  (% class="box infomessage" %)
... ... @@ -850,7 +850,6 @@
850 850  
851 851  0: Disable Trigger Mode
852 852  
853 -
854 854  * Downlink Payload (prefix 0x0A 06):
855 855  
856 856  (% class="box infomessage" %)
... ... @@ -868,7 +868,6 @@
868 868  
869 869  There is no AT Command for this feature.
870 870  
871 -
872 872  * Downlink Payload (prefix 0x AB 06):
873 873  
874 874  (% class="box infomessage" %)
... ... @@ -889,7 +889,6 @@
889 889  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
890 890  )))
891 891  
892 -
893 893  **Example:**
894 894  
895 895  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -918,12 +918,10 @@
918 918  
919 919  b : delay timing.
920 920  
921 -
922 922  **Example:**
923 923  
924 924  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
925 925  
926 -
927 927  * Downlink Payload (prefix 0x09 01 ):
928 928  
929 929  (% class="box infomessage" %)
... ... @@ -948,12 +948,10 @@
948 948  
949 949  b : delay timing.
950 950  
951 -
952 952  **Example:**
953 953  
954 954  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
955 955  
956 -
957 957  * Downlink Payload (prefix 0x09 02 ):
958 958  
959 959  (% class="box infomessage" %)
... ... @@ -974,7 +974,6 @@
974 974  **AT+ACLIM. **
975 975  )))
976 976  
977 -
978 978  * Downlink Payload (prefix 0xAA 01 ):
979 979  
980 980  (% class="box infomessage" %)
... ... @@ -995,7 +995,6 @@
995 995  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
996 996  )))
997 997  
998 -
999 999  * Downlink Payload (prefix 0xAA 00 ):
1000 1000  
1001 1001  (% class="box infomessage" %)
... ... @@ -1016,7 +1016,6 @@
1016 1016  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1017 1017  )))
1018 1018  
1019 -
1020 1020  * Downlink Payload (prefix 0xAC ):
1021 1021  
1022 1022  (% class="box infomessage" %)
... ... @@ -1032,7 +1032,6 @@
1032 1032  
1033 1033  There is no AT Command to control Digital Output
1034 1034  
1035 -
1036 1036  * Downlink Payload (prefix 0x02):
1037 1037  
1038 1038  (% class="box infomessage" %)
... ... @@ -1066,7 +1066,6 @@
1066 1066  
1067 1067  There is no AT Command to control Digital Output
1068 1068  
1069 -
1070 1070  * Downlink Payload (prefix 0xA9):
1071 1071  
1072 1072  (% class="box infomessage" %)
... ... @@ -1086,22 +1086,18 @@
1086 1086  
1087 1087  00: DO pins will change to an inverter state after timeout 
1088 1088  
1089 -
1090 1090  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1091 1091  
1092 1092  [[image:image-20220524093238-6.png]]
1093 1093  
1094 -
1095 1095  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1096 1096  
1097 1097  [[image:image-20220524093328-7.png]]
1098 1098  
1099 -
1100 1100  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1101 1101  
1102 1102  [[image:image-20220524093351-8.png]]
1103 1103  
1104 -
1105 1105  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1106 1106  
1107 1107   Latching time. Unit: ms
... ... @@ -1108,7 +1108,6 @@
1108 1108  
1109 1109  Device will upload a packet if downlink code executes successfully.
1110 1110  
1111 -
1112 1112  **Example payload:**
1113 1113  
1114 1114  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1129,13 +1129,12 @@
1129 1129  
1130 1130  
1131 1131  
1132 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1133 1133  
1134 1134  * AT Command:
1135 1135  
1136 1136  There is no AT Command to control Relay Output
1137 1137  
1138 -
1139 1139  * Downlink Payload (prefix 0x03):
1140 1140  
1141 1141  (% class="box infomessage" %)
... ... @@ -1165,7 +1165,6 @@
1165 1165  
1166 1166  There is no AT Command to control Relay Output
1167 1167  
1168 -
1169 1169  * Downlink Payload (prefix 0x05):
1170 1170  
1171 1171  (% class="box infomessage" %)
... ... @@ -1225,7 +1225,6 @@
1225 1225  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1226 1226  )))
1227 1227  
1228 -
1229 1229  * Downlink Payload (prefix 0xA5):
1230 1230  
1231 1231  (% class="box infomessage" %)
... ... @@ -1252,7 +1252,6 @@
1252 1252  
1253 1253  Bb cc dd ee: number to be set
1254 1254  
1255 -
1256 1256  * Downlink Payload (prefix 0xA8):
1257 1257  
1258 1258  (% class="box infomessage" %)