Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,6 +275,7 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 286 + 287 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 301 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -326,7 +326,6 @@ 326 326 ** DO1 LED is off in both case 327 327 328 328 329 - 330 330 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 331 331 332 332 ... ... @@ -619,13 +619,11 @@ 619 619 * **AT+MOD=1 ** **~-~->** The normal working mode 620 620 * **AT+ADDMOD6=1** **~-~->** Enable trigger 621 621 622 - 623 623 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 624 624 625 625 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 626 626 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 627 627 628 - 629 629 **AT Command to set Trigger Condition**: 630 630 631 631 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -654,12 +654,13 @@ 654 654 655 655 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 656 656 658 + 657 657 **Example:** 658 658 659 659 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 660 660 661 661 662 -**Downlink Command to set Trigger Condition** 664 +**Downlink Command to set Trigger Condition:** 663 663 664 664 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 665 665 ... ... @@ -688,6 +688,7 @@ 688 688 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 689 689 690 690 693 + 691 691 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 692 692 693 693 MOD6 Payload : total 11 bytes payload ... ... @@ -702,6 +702,7 @@ 702 702 * Each bits shows if the corresponding trigger has been configured. 703 703 704 704 708 + 705 705 **Example:** 706 706 707 707 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -714,6 +714,7 @@ 714 714 * Each bits shows which status has been trigger on this uplink. 715 715 716 716 721 + 717 717 **Example:** 718 718 719 719 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -726,6 +726,7 @@ 726 726 * Each bits shows which status has been trigger on this uplink. 727 727 728 728 734 + 729 729 **Example:** 730 730 731 731 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.