... ... @@ -310,6 +310,7 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 +
313 313  **LT22222-L:**
314 314  
315 315  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -619,13 +619,11 @@
619 619  * **AT+MOD=1 ** **~-~->** The normal working mode
620 620  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
621 621  
622 -
623 623  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
624 624  
625 625  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
626 626  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
627 627  
628 -
629 629  **AT Command to set Trigger Condition**:
630 630  
631 631  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -701,7 +701,6 @@
701 701  
702 702  * Each bits shows if the corresponding trigger has been configured.
703 703  
704 -
705 705  **Example:**
706 706  
707 707  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -713,7 +713,6 @@
713 713  
714 714  * Each bits shows which status has been trigger on this uplink.
715 715  
716 -
717 717  **Example:**
718 718  
719 719  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -725,7 +725,6 @@
725 725  
726 726  * Each bits shows which status has been trigger on this uplink.
727 727  
728 -
729 729  **Example:**
730 730  
731 731  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -768,7 +768,6 @@
768 768  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
769 769  
770 770  
771 -
772 772  === 3.4.1 Common Commands ===
773 773  
774 774  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]