... ... @@ -325,11 +325,8 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
328 -
329 -
330 330  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
331 331  
332 -
333 333  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
334 334  
335 335  (((
... ... @@ -338,7 +338,6 @@
338 338  
339 339  [[image:image-20220523180452-3.png]]
340 340  
341 -
342 342  (((
343 343  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
344 344  )))
... ... @@ -354,8 +354,6 @@
354 354  )))
355 355  
356 356  (((
357 -
358 -
359 359  **To use counting mode, please run:**
360 360  )))
361 361  
... ... @@ -374,8 +374,6 @@
374 374  )))
375 375  
376 376  (((
377 -
378 -
379 379  (% style="color:#4f81bd" %)**AT Commands for counting:**
380 380  )))
381 381  
... ... @@ -472,9 +472,9 @@
472 472  )))
473 473  
474 474  
467 +
475 475  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
476 476  
477 -
478 478  **LT22222-L**: This mode the DI1 is used as a counting pin.
479 479  
480 480  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -481,7 +481,6 @@
481 481  
482 482  [[image:image-20220523181903-8.png]]
483 483  
484 -
485 485  (((
486 486  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
487 487  )))
... ... @@ -562,7 +562,6 @@
562 562  
563 563  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
564 564  
565 -
566 566  **LT22222-L**: This mode the DI1 is used as a counting pin.
567 567  
568 568  [[image:image-20220523182334-9.png]]
... ... @@ -611,7 +611,6 @@
611 611  
612 612  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
613 613  
614 -
615 615  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
616 616  
617 617  For example, if user has configured below commands:
... ... @@ -746,8 +746,6 @@
746 746  === 3.3.7 Payload Decoder ===
747 747  
748 748  (((
749 -
750 -
751 751  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
752 752  
753 753  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved