From version < 77.86 >
edited by Xiaoling
on 2022/06/10 09:27
To version < 77.73 >
edited by Xiaoling
on 2022/06/10 09:23
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -325,11 +325,8 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
328 -
329 -
330 330  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
331 331  
332 -
333 333  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
334 334  
335 335  (((
... ... @@ -338,7 +338,6 @@
338 338  
339 339  [[image:image-20220523180452-3.png]]
340 340  
341 -
342 342  (((
343 343  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
344 344  )))
... ... @@ -354,8 +354,6 @@
354 354  )))
355 355  
356 356  (((
357 -
358 -
359 359  **To use counting mode, please run:**
360 360  )))
361 361  
... ... @@ -374,8 +374,6 @@
374 374  )))
375 375  
376 376  (((
377 -
378 -
379 379  (% style="color:#4f81bd" %)**AT Commands for counting:**
380 380  )))
381 381  
... ... @@ -472,9 +472,9 @@
472 472  )))
473 473  
474 474  
467 +
475 475  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
476 476  
477 -
478 478  **LT22222-L**: This mode the DI1 is used as a counting pin.
479 479  
480 480  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -481,7 +481,6 @@
481 481  
482 482  [[image:image-20220523181903-8.png]]
483 483  
484 -
485 485  (((
486 486  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
487 487  )))
... ... @@ -497,8 +497,6 @@
497 497  )))
498 498  
499 499  (((
500 -
501 -
502 502  **To use this mode, please run:**
503 503  )))
504 504  
... ... @@ -525,8 +525,6 @@
525 525  )))
526 526  
527 527  (((
528 -
529 -
530 530  **Plus below command for AVI1 Counting:**
531 531  )))
532 532  
... ... @@ -562,14 +562,11 @@
562 562  
563 563  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
564 564  
565 -
566 566  **LT22222-L**: This mode the DI1 is used as a counting pin.
567 567  
568 568  [[image:image-20220523182334-9.png]]
569 569  
570 570  (((
571 -
572 -
573 573  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
574 574  )))
575 575  
... ... @@ -584,8 +584,6 @@
584 584  )))
585 585  
586 586  (((
587 -
588 -
589 589  **To use this mode, please run:**
590 590  )))
591 591  
... ... @@ -605,6 +605,8 @@
605 605  
606 606  (((
607 607  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
608 608  )))
609 609  
610 610  
... ... @@ -611,7 +611,6 @@
611 611  
612 612  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
613 613  
614 -
615 615  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
616 616  
617 617  For example, if user has configured below commands:
... ... @@ -619,13 +619,11 @@
619 619  * **AT+MOD=1 ** **~-~->** The normal working mode
620 620  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
621 621  
622 -
623 623  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
624 624  
625 625  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
626 626  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
627 627  
628 -
629 629  **AT Command to set Trigger Condition**:
630 630  
631 631  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -677,12 +677,10 @@
677 677  
678 678   Yy4 yy4: AC2 or AV2 high limit.
679 679  
680 -
681 681  **Example1**: AA 00 13 88 00 00 00 00 00 00
682 682  
683 683  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
684 684  
685 -
686 686  **Example2**: AA 02 01 00
687 687  
688 688  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -725,7 +725,6 @@
725 725  
726 726  * Each bits shows which status has been trigger on this uplink.
727 727  
728 -
729 729  **Example:**
730 730  
731 731  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -746,8 +746,6 @@
746 746  === 3.3.7 Payload Decoder ===
747 747  
748 748  (((
749 -
750 -
751 751  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
752 752  
753 753  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0