Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 278 + 279 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 287 + 288 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 302 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -310,6 +310,7 @@ 310 310 * [1] RO1 relay channel is close and the RO1 LED is ON. 311 311 * [0] RO2 relay channel is open and RO2 LED is OFF; 312 312 318 + 313 313 **LT22222-L:** 314 314 315 315 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -325,6 +325,8 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 334 + 335 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 330 330 ... ... @@ -617,13 +617,11 @@ 617 617 * **AT+MOD=1 ** **~-~->** The normal working mode 618 618 * **AT+ADDMOD6=1** **~-~->** Enable trigger 619 619 620 - 621 621 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 622 622 623 623 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 624 624 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 625 625 626 - 627 627 **AT Command to set Trigger Condition**: 628 628 629 629 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -699,7 +699,6 @@ 699 699 700 700 * Each bits shows if the corresponding trigger has been configured. 701 701 702 - 703 703 **Example:** 704 704 705 705 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -711,7 +711,6 @@ 711 711 712 712 * Each bits shows which status has been trigger on this uplink. 713 713 714 - 715 715 **Example:** 716 716 717 717 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -723,7 +723,6 @@ 723 723 724 724 * Each bits shows which status has been trigger on this uplink. 725 725 726 - 727 727 **Example:** 728 728 729 729 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -767,6 +767,7 @@ 767 767 768 768 769 769 773 + 770 770 === 3.4.1 Common Commands === 771 771 772 772 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]