... ... @@ -327,7 +327,6 @@
327 327  
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
330 -
331 331  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
332 332  
333 333  (((
... ... @@ -336,7 +336,6 @@
336 336  
337 337  [[image:image-20220523180452-3.png]]
338 338  
339 -
340 340  (((
341 341  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
342 342  )))
... ... @@ -352,8 +352,6 @@
352 352  )))
353 353  
354 354  (((
355 -
356 -
357 357  **To use counting mode, please run:**
358 358  )))
359 359  
... ... @@ -372,8 +372,6 @@
372 372  )))
373 373  
374 374  (((
375 -
376 -
377 377  (% style="color:#4f81bd" %)**AT Commands for counting:**
378 378  )))
379 379  
... ... @@ -470,9 +470,9 @@
470 470  )))
471 471  
472 472  
467 +
473 473  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
474 474  
475 -
476 476  **LT22222-L**: This mode the DI1 is used as a counting pin.
477 477  
478 478  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -479,7 +479,6 @@
479 479  
480 480  [[image:image-20220523181903-8.png]]
481 481  
482 -
483 483  (((
484 484  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
485 485  )))
... ... @@ -495,8 +495,6 @@
495 495  )))
496 496  
497 497  (((
498 -
499 -
500 500  **To use this mode, please run:**
501 501  )))
502 502  
... ... @@ -523,8 +523,6 @@
523 523  )))
524 524  
525 525  (((
526 -
527 -
528 528  **Plus below command for AVI1 Counting:**
529 529  )))
530 530  
... ... @@ -560,14 +560,11 @@
560 560  
561 561  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
562 562  
563 -
564 564  **LT22222-L**: This mode the DI1 is used as a counting pin.
565 565  
566 566  [[image:image-20220523182334-9.png]]
567 567  
568 568  (((
569 -
570 -
571 571  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
572 572  )))
573 573  
... ... @@ -582,8 +582,6 @@
582 582  )))
583 583  
584 584  (((
585 -
586 -
587 587  **To use this mode, please run:**
588 588  )))
589 589  
... ... @@ -603,6 +603,8 @@
603 603  
604 604  (((
605 605  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
606 606  )))
607 607  
608 608  
... ... @@ -609,7 +609,6 @@
609 609  
610 610  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
611 611  
612 -
613 613  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
614 614  
615 615  For example, if user has configured below commands:
... ... @@ -617,13 +617,11 @@
617 617  * **AT+MOD=1 ** **~-~->** The normal working mode
618 618  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
619 619  
620 -
621 621  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
622 622  
623 623  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
624 624  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
625 625  
626 -
627 627  **AT Command to set Trigger Condition**:
628 628  
629 629  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -675,12 +675,10 @@
675 675  
676 676   Yy4 yy4: AC2 or AV2 high limit.
677 677  
678 -
679 679  **Example1**: AA 00 13 88 00 00 00 00 00 00
680 680  
681 681  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
682 682  
683 -
684 684  **Example2**: AA 02 01 00
685 685  
686 686  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -723,7 +723,6 @@
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
726 -
727 727  **Example:**
728 728  
729 729  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -744,8 +744,6 @@
744 744  === 3.3.7 Payload Decoder ===
745 745  
746 746  (((
747 -
748 -
749 749  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
750 750  
751 751  