Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -499,20 +499,13 @@ 499 499 ((( 500 500 ((( 501 501 **AT+MOD=4** 502 -))) 503 -))) 504 504 505 -(% class="box infomessage" %) 506 -((( 507 -((( 508 508 **ATZ** 509 509 ))) 510 510 ))) 511 511 512 -((( 513 - 514 -))) 515 515 497 + 516 516 ((( 517 517 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 518 518 ))) ... ... @@ -526,33 +526,17 @@ 526 526 (% class="box infomessage" %) 527 527 ((( 528 528 ((( 529 -**AT+SETCNT=3,60 (set AVI Count to 60)** 530 -))) 531 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 532 532 533 -(% class="box infomessage" %) 534 -((( 535 -((( 536 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 537 -))) 538 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 539 539 540 -(% class="box infomessage" %) 541 -((( 542 -((( 543 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 544 -))) 545 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 546 546 547 -(% class="box infomessage" %) 548 -((( 549 -((( 550 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 551 551 ))) 552 552 ))) 553 553 554 554 555 - 556 556 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 557 557 558 558 ... ... @@ -586,12 +586,7 @@ 586 586 ((( 587 587 ((( 588 588 **AT+MOD=5** 589 -))) 590 -))) 591 591 592 -(% class="box infomessage" %) 593 -((( 594 -((( 595 595 **ATZ** 596 596 ))) 597 597 ))) ... ... @@ -604,6 +604,7 @@ 604 604 605 605 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 606 606 568 + 607 607 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 608 608 609 609 For example, if user has configured below commands: ... ... @@ -611,15 +611,13 @@ 611 611 * **AT+MOD=1 ** **~-~->** The normal working mode 612 612 * **AT+ADDMOD6=1** **~-~->** Enable trigger 613 613 614 - 615 615 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 616 616 617 617 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 618 618 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 619 619 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 620 620 621 -**AT Command to set Trigger Condition**: 622 - 623 623 (% style="color:#4f81bd" %)**Trigger base on voltage**: 624 624 625 625 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -631,6 +631,7 @@ 631 631 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 632 632 633 633 594 + 634 634 (% style="color:#4f81bd" %)**Trigger base on current**: 635 635 636 636 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -640,6 +640,7 @@ 640 640 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 641 641 642 642 604 + 643 643 (% style="color:#4f81bd" %)**Trigger base on DI status**: 644 644 645 645 DI status trigger Flag. ... ... @@ -646,12 +646,13 @@ 646 646 647 647 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 648 648 611 + 649 649 **Example:** 650 650 651 651 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 652 652 653 653 654 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 655 655 656 656 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 657 657 ... ... @@ -680,6 +680,7 @@ 680 680 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 681 681 682 682 646 + 683 683 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 684 684 685 685 MOD6 Payload : total 11 bytes payload ... ... @@ -693,7 +693,6 @@ 693 693 694 694 * Each bits shows if the corresponding trigger has been configured. 695 695 696 - 697 697 **Example:** 698 698 699 699 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -705,7 +705,6 @@ 705 705 706 706 * Each bits shows which status has been trigger on this uplink. 707 707 708 - 709 709 **Example:** 710 710 711 711 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -717,7 +717,6 @@ 717 717 718 718 * Each bits shows which status has been trigger on this uplink. 719 719 720 - 721 721 **Example:** 722 722 723 723 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -738,6 +738,8 @@ 738 738 === 3.3.7 Payload Decoder === 739 739 740 740 ((( 702 + 703 + 741 741 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 742 742 743 743 ... ... @@ -744,7 +744,6 @@ 744 744 ))) 745 745 746 746 747 - 748 748 == 3.4 Configure LT via AT or Downlink == 749 749 750 750 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -771,7 +771,7 @@ 771 771 772 772 Set device uplink interval. 773 773 774 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 775 775 776 776 (% class="box infomessage" %) 777 777 ((( ... ... @@ -781,7 +781,7 @@ 781 781 **Example: **AT+TDC=30000. Means set interval to 30 seconds 782 782 783 783 784 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 785 785 786 786 (% class="box infomessage" %) 787 787 ((( ... ... @@ -794,7 +794,7 @@ 794 794 795 795 Set work mode. 796 796 797 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 798 798 799 799 (% class="box infomessage" %) 800 800 ((( ... ... @@ -804,7 +804,7 @@ 804 804 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 805 805 806 806 807 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 808 808 809 809 (% class="box infomessage" %) 810 810 ((( ... ... @@ -815,12 +815,12 @@ 815 815 816 816 ==== 3.4.2.3 Poll an uplink ==== 817 817 818 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 819 819 820 820 There is no AT Command to poll uplink 821 821 822 822 823 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 824 824 825 825 (% class="box infomessage" %) 826 826 ((( ... ... @@ -835,7 +835,7 @@ 835 835 836 836 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 837 837 838 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 839 839 840 840 (% class="box infomessage" %) 841 841 ((( ... ... @@ -847,7 +847,7 @@ 847 847 0: Disable Trigger Mode 848 848 849 849 850 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 851 851 852 852 (% class="box infomessage" %) 853 853 ((( ... ... @@ -860,12 +860,12 @@ 860 860 861 861 Poll trigger settings, 862 862 863 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 864 864 865 865 There is no AT Command for this feature. 866 866 867 867 868 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 869 869 870 870 (% class="box infomessage" %) 871 871 ((( ... ... @@ -878,7 +878,7 @@ 878 878 879 879 Enable Disable DI1/DI2/DI2 as trigger, 880 880 881 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 882 882 883 883 (% class="box infomessage" %) 884 884 ((( ... ... @@ -890,7 +890,7 @@ 890 890 891 891 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 892 892 893 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 894 894 895 895 (% class="box infomessage" %) 896 896 ((( ... ... @@ -903,7 +903,7 @@ 903 903 904 904 Set DI1 or DI3(for LT-33222-L) trigger. 905 905 906 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 907 907 908 908 (% class="box infomessage" %) 909 909 ((( ... ... @@ -920,7 +920,7 @@ 920 920 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 921 921 922 922 923 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 924 924 925 925 (% class="box infomessage" %) 926 926 ((( ... ... @@ -933,7 +933,7 @@ 933 933 934 934 Set DI2 trigger. 935 935 936 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 937 937 938 938 (% class="box infomessage" %) 939 939 ((( ... ... @@ -950,7 +950,7 @@ 950 950 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 951 951 952 952 953 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 954 954 955 955 (% class="box infomessage" %) 956 956 ((( ... ... @@ -963,7 +963,7 @@ 963 963 964 964 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 965 965 966 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 967 967 968 968 (% class="box infomessage" %) 969 969 ((( ... ... @@ -971,7 +971,7 @@ 971 971 ))) 972 972 973 973 974 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 975 975 976 976 (% class="box infomessage" %) 977 977 ((( ... ... @@ -984,7 +984,7 @@ 984 984 985 985 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 986 986 987 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 988 988 989 989 (% class="box infomessage" %) 990 990 ((( ... ... @@ -992,7 +992,7 @@ 992 992 ))) 993 993 994 994 995 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 996 996 997 997 (% class="box infomessage" %) 998 998 ((( ... ... @@ -1005,7 +1005,7 @@ 1005 1005 1006 1006 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1007 1007 1008 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1009 1009 1010 1010 (% class="box infomessage" %) 1011 1011 ((( ... ... @@ -1013,7 +1013,7 @@ 1013 1013 ))) 1014 1014 1015 1015 1016 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1017 1017 1018 1018 (% class="box infomessage" %) 1019 1019 ((( ... ... @@ -1024,12 +1024,12 @@ 1024 1024 1025 1025 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1026 1026 1027 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1028 1028 1029 1029 There is no AT Command to control Digital Output 1030 1030 1031 1031 1032 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1033 1033 1034 1034 (% class="box infomessage" %) 1035 1035 ((( ... ... @@ -1058,12 +1058,12 @@ 1058 1058 1059 1059 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1060 1060 1061 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1062 1062 1063 1063 There is no AT Command to control Digital Output 1064 1064 1065 1065 1066 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1067 1067 1068 1068 (% class="box infomessage" %) 1069 1069 ((( ... ... @@ -1127,12 +1127,12 @@ 1127 1127 1128 1128 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1129 1129 1130 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1131 1131 1132 1132 There is no AT Command to control Relay Output 1133 1133 1134 1134 1135 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1136 1136 1137 1137 (% class="box infomessage" %) 1138 1138 ((( ... ... @@ -1157,12 +1157,12 @@ 1157 1157 1158 1158 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1159 1159 1160 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1161 1161 1162 1162 There is no AT Command to control Relay Output 1163 1163 1164 1164 1165 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1166 1166 1167 1167 (% class="box infomessage" %) 1168 1168 ((( ... ... @@ -1214,7 +1214,7 @@ 1214 1214 1215 1215 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1216 1216 1217 -* AT Command: 1179 +* (% style="color:#037691" %)AT Command: 1218 1218 1219 1219 (% class="box infomessage" %) 1220 1220 ((( ... ... @@ -1222,7 +1222,7 @@ 1222 1222 ))) 1223 1223 1224 1224 1225 -* Downlink Payload (prefix 0xA5): 1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1226 1226 1227 1227 (% class="box infomessage" %) 1228 1228 ((( ... ... @@ -1233,7 +1233,7 @@ 1233 1233 1234 1234 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1235 1235 1236 -* AT Command: 1198 +* (% style="color:#037691" %)AT Command: 1237 1237 1238 1238 (% class="box infomessage" %) 1239 1239 ((( ... ... @@ -1249,7 +1249,7 @@ 1249 1249 Bb cc dd ee: number to be set 1250 1250 1251 1251 1252 -* Downlink Payload (prefix 0xA8): 1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1253 1253 1254 1254 (% class="box infomessage" %) 1255 1255 ((( ... ... @@ -1262,38 +1262,28 @@ 1262 1262 1263 1263 Clear counting for counting mode 1264 1264 1265 -* AT Command: 1227 +* (% style="color:#037691" %)**AT Command:** 1266 1266 1267 -(% class="box infomessage" %) 1268 -((( 1269 -**AT+CLRCOUNT ~/~/ clear all counting** 1270 -))) 1229 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1271 1271 1272 -* Downlink Payload (prefix 0xA6): 1273 1273 1274 -(% class="box infomessage" %) 1275 -((( 1276 -**0x A6 01 ~/~/ clear all counting,** 1277 -))) 1232 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1278 1278 1234 +**0x A6 01 ** ~/~/ clear all counting 1279 1279 1280 1280 1237 + 1281 1281 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1282 1282 1283 -* AT Command: 1240 +* (% style="color:#037691" %)**AT Command:** 1284 1284 1285 -(% class="box infomessage" %) 1286 -((( 1287 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1288 -))) 1242 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1289 1289 1290 -* Downlink Payload (prefix 0xA7): 1291 1291 1292 -(% class="box infomessage" %) 1293 -((( 1294 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1295 -))) 1245 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1296 1296 1247 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1248 + 1297 1297 ((( 1298 1298 range: aa bb cc:0 to 16777215, (unit:second) 1299 1299 ... ... @@ -1990,8 +1990,16 @@ 1990 1990 ))) 1991 1991 1992 1992 ((( 1993 - 1945 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1994 1994 1947 +If the device is not shut down, but directly powered off. 1948 + 1949 +It will default that this is a power-off state. 1950 + 1951 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1952 + 1953 +After restart, the status before power failure will be read from flash. 1954 + 1995 1995 = 6. Trouble Shooting = 1996 1996 ))) 1997 1997