275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
278 +
279 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
287 +
288 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -295,6 +295,7 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
302 +
298 298  **The value for the interface is:  **
299 299  
300 300  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -310,6 +310,7 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
318 +
313 313  **LT22222-L:**
314 314  
315 315  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -325,8 +325,11 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
334 +
335 +
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
338 +
330 330  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
331 331  
332 332  (((
... ... @@ -335,6 +335,7 @@
335 335  
336 336  [[image:image-20220523180452-3.png]]
337 337  
347 +
338 338  (((
339 339  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
340 340  )))
... ... @@ -350,6 +350,8 @@
350 350  )))
351 351  
352 352  (((
363 +
364 +
353 353  **To use counting mode, please run:**
354 354  )))
355 355  
... ... @@ -368,6 +368,8 @@
368 368  )))
369 369  
370 370  (((
383 +
384 +
371 371  (% style="color:#4f81bd" %)**AT Commands for counting:**
372 372  )))
373 373  
... ... @@ -464,9 +464,9 @@
464 464  )))
465 465  
466 466  
467 -
468 468  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
469 469  
483 +
470 470  **LT22222-L**: This mode the DI1 is used as a counting pin.
471 471  
472 472  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -473,6 +473,7 @@
473 473  
474 474  [[image:image-20220523181903-8.png]]
475 475  
490 +
476 476  (((
477 477  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
478 478  )))
... ... @@ -602,6 +602,7 @@
602 602  
603 603  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
604 604  
620 +
605 605  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
606 606  
607 607  For example, if user has configured below commands:
... ... @@ -609,13 +609,11 @@
609 609  * **AT+MOD=1 ** **~-~->** The normal working mode
610 610  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
611 611  
612 -
613 613  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
614 614  
615 615  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
616 616  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
617 617  
618 -
619 619  **AT Command to set Trigger Condition**:
620 620  
621 621  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -691,7 +691,6 @@
691 691  
692 692  * Each bits shows if the corresponding trigger has been configured.
693 693  
694 -
695 695  **Example:**
696 696  
697 697  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -703,7 +703,6 @@
703 703  
704 704  * Each bits shows which status has been trigger on this uplink.
705 705  
706 -
707 707  **Example:**
708 708  
709 709  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -715,7 +715,6 @@
715 715  
716 716  * Each bits shows which status has been trigger on this uplink.
717 717  
718 -
719 719  **Example:**
720 720  
721 721  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -736,6 +736,8 @@
736 736  === 3.3.7 Payload Decoder ===
737 737  
738 738  (((
750 +
751 +
739 739  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
740 740  
741 741  
... ... @@ -756,7 +756,6 @@
756 756  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
757 757  
758 758  
759 -
760 760  === 3.4.1 Common Commands ===
761 761  
762 762  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]