<
From version < 77.81 >
edited by Xiaoling
on 2022/06/10 09:25
To version < 77.68 >
edited by Xiaoling
on 2022/06/10 09:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -488,8 +488,6 @@
488 488  )))
489 489  
490 490  (((
491 -
492 -
493 493  **To use this mode, please run:**
494 494  )))
495 495  
... ... @@ -516,8 +516,6 @@
516 516  )))
517 517  
518 518  (((
519 -
520 -
521 521  **Plus below command for AVI1 Counting:**
522 522  )))
523 523  
... ... @@ -553,14 +553,11 @@
553 553  
554 554  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
555 555  
556 -
557 557  **LT22222-L**: This mode the DI1 is used as a counting pin.
558 558  
559 559  [[image:image-20220523182334-9.png]]
560 560  
561 561  (((
562 -
563 -
564 564  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
565 565  )))
566 566  
... ... @@ -575,8 +575,6 @@
575 575  )))
576 576  
577 577  (((
578 -
579 -
580 580  **To use this mode, please run:**
581 581  )))
582 582  
... ... @@ -596,6 +596,8 @@
596 596  
597 597  (((
598 598  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
599 599  )))
600 600  
601 601  
... ... @@ -609,13 +609,11 @@
609 609  * **AT+MOD=1 ** **~-~->** The normal working mode
610 610  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
611 611  
612 -
613 613  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
614 614  
615 615  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
616 616  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
617 617  
618 -
619 619  **AT Command to set Trigger Condition**:
620 620  
621 621  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -667,17 +667,14 @@
667 667  
668 668   Yy4 yy4: AC2 or AV2 high limit.
669 669  
670 -
671 671  **Example1**: AA 00 13 88 00 00 00 00 00 00
672 672  
673 673  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
674 674  
675 -
676 676  **Example2**: AA 02 01 00
677 677  
678 678  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
679 679  
680 -
681 681  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
682 682  
683 683  MOD6 Payload : total 11 bytes payload
... ... @@ -684,7 +684,6 @@
684 684  
685 685  [[image:image-20220524085923-1.png]]
686 686  
687 -
688 688  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
689 689  
690 690  [[image:image-20220524090106-2.png]]
... ... @@ -691,7 +691,6 @@
691 691  
692 692  * Each bits shows if the corresponding trigger has been configured.
693 693  
694 -
695 695  **Example:**
696 696  
697 697  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -703,7 +703,6 @@
703 703  
704 704  * Each bits shows which status has been trigger on this uplink.
705 705  
706 -
707 707  **Example:**
708 708  
709 709  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -715,7 +715,6 @@
715 715  
716 716  * Each bits shows which status has been trigger on this uplink.
717 717  
718 -
719 719  **Example:**
720 720  
721 721  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -756,7 +756,6 @@
756 756  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
757 757  
758 758  
759 -
760 760  === 3.4.1 Common Commands ===
761 761  
762 762  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1123,7 +1123,7 @@
1123 1123  
1124 1124  
1125 1125  
1126 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1109 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1127 1127  
1128 1128  * AT Command:
1129 1129  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0