From version < 77.81 >
edited by Xiaoling
on 2022/06/10 09:25
To version < 77.102 >
edited by Xiaoling
on 2022/06/10 09:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -230,12 +230,13 @@
230 230  
231 231  [[image:image-20220523172350-1.png||height="266" width="864"]]
232 232  
233 +
233 233  (((
234 234  The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN:
235 235  )))
236 236  
237 237  (((
238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller.
239 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.
239 239  )))
240 240  
241 241  (((
... ... @@ -244,6 +244,7 @@
244 244  
245 245  [[image:1653297924498-393.png]]
246 246  
248 +
247 247  Input these keys in the LoRaWAN Server portal. Below is TTN screen shot:
248 248  
249 249  Add APP EUI in the application.
... ... @@ -257,7 +257,7 @@
257 257  
258 258  
259 259  (((
260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
262 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.
261 261  )))
262 262  
263 263  [[image:1653298044601-602.png||height="405" width="709"]]
... ... @@ -275,6 +275,7 @@
275 275  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
276 276  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 277  
280 +
278 278  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
279 279  
280 280  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -282,6 +282,8 @@
282 282  [[image:image-20220523174024-3.png]]
283 283  
284 284  (((
288 +
289 +
285 285  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
286 286  )))
287 287  
... ... @@ -295,6 +295,7 @@
295 295  
296 296  For example if payload is: [[image:image-20220523175847-2.png]]
297 297  
303 +
298 298  **The value for the interface is:  **
299 299  
300 300  AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V
... ... @@ -310,6 +310,7 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
319 +
313 313  **LT22222-L:**
314 314  
315 315  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -325,8 +325,10 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
335 +
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
338 +
330 330  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
331 331  
332 332  (((
... ... @@ -335,6 +335,7 @@
335 335  
336 336  [[image:image-20220523180452-3.png]]
337 337  
347 +
338 338  (((
339 339  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
340 340  )))
... ... @@ -350,6 +350,8 @@
350 350  )))
351 351  
352 352  (((
363 +
364 +
353 353  **To use counting mode, please run:**
354 354  )))
355 355  
... ... @@ -368,6 +368,8 @@
368 368  )))
369 369  
370 370  (((
383 +
384 +
371 371  (% style="color:#4f81bd" %)**AT Commands for counting:**
372 372  )))
373 373  
... ... @@ -464,9 +464,9 @@
464 464  )))
465 465  
466 466  
467 -
468 468  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
469 469  
483 +
470 470  **LT22222-L**: This mode the DI1 is used as a counting pin.
471 471  
472 472  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -473,6 +473,7 @@
473 473  
474 474  [[image:image-20220523181903-8.png]]
475 475  
490 +
476 476  (((
477 477  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
478 478  )))
... ... @@ -602,6 +602,7 @@
602 602  
603 603  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
604 604  
620 +
605 605  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
606 606  
607 607  For example, if user has configured below commands:
... ... @@ -609,7 +609,6 @@
609 609  * **AT+MOD=1 ** **~-~->** The normal working mode
610 610  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
611 611  
612 -
613 613  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
614 614  
615 615  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
... ... @@ -629,6 +629,7 @@
629 629  AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
630 630  
631 631  
647 +
632 632  (% style="color:#4f81bd" %)**Trigger base on current**:
633 633  
634 634  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
... ... @@ -638,6 +638,7 @@
638 638  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
639 639  
640 640  
657 +
641 641  (% style="color:#4f81bd" %)**Trigger base on DI status**:
642 642  
643 643  DI status trigger Flag.
... ... @@ -644,12 +644,13 @@
644 644  
645 645  Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >
646 646  
664 +
647 647  **Example:**
648 648  
649 649  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
650 650  
651 651  
652 -**Downlink Command to set Trigger Condition**
670 +**Downlink Command to set Trigger Condition:**
653 653  
654 654  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
655 655  
... ... @@ -678,6 +678,7 @@
678 678  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
679 679  
680 680  
699 +
681 681  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
682 682  
683 683  MOD6 Payload : total 11 bytes payload
... ... @@ -736,6 +736,8 @@
736 736  === 3.3.7 Payload Decoder ===
737 737  
738 738  (((
758 +
759 +
739 739  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
740 740  
741 741  
... ... @@ -756,7 +756,6 @@
756 756  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
757 757  
758 758  
759 -
760 760  === 3.4.1 Common Commands ===
761 761  
762 762  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0