<
From version < 77.80 >
edited by Xiaoling
on 2022/06/10 09:25
To version < 77.60 >
edited by Xiaoling
on 2022/06/10 09:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -488,8 +488,6 @@
488 488  )))
489 489  
490 490  (((
491 -
492 -
493 493  **To use this mode, please run:**
494 494  )))
495 495  
... ... @@ -516,8 +516,6 @@
516 516  )))
517 517  
518 518  (((
519 -
520 -
521 521  **Plus below command for AVI1 Counting:**
522 522  )))
523 523  
... ... @@ -558,8 +558,6 @@
558 558  [[image:image-20220523182334-9.png]]
559 559  
560 560  (((
561 -
562 -
563 563  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
564 564  )))
565 565  
... ... @@ -574,8 +574,6 @@
574 574  )))
575 575  
576 576  (((
577 -
578 -
579 579  **To use this mode, please run:**
580 580  )))
581 581  
... ... @@ -595,6 +595,8 @@
595 595  
596 596  (((
597 597  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
590 +
591 +
598 598  )))
599 599  
600 600  
... ... @@ -608,13 +608,11 @@
608 608  * **AT+MOD=1 ** **~-~->** The normal working mode
609 609  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
610 610  
611 -
612 612  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
613 613  
614 614  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
615 615  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
616 616  
617 -
618 618  **AT Command to set Trigger Condition**:
619 619  
620 620  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -666,17 +666,14 @@
666 666  
667 667   Yy4 yy4: AC2 or AV2 high limit.
668 668  
669 -
670 670  **Example1**: AA 00 13 88 00 00 00 00 00 00
671 671  
672 672  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
673 673  
674 -
675 675  **Example2**: AA 02 01 00
676 676  
677 677  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
678 678  
679 -
680 680  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
681 681  
682 682  MOD6 Payload : total 11 bytes payload
... ... @@ -683,7 +683,6 @@
683 683  
684 684  [[image:image-20220524085923-1.png]]
685 685  
686 -
687 687  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
688 688  
689 689  [[image:image-20220524090106-2.png]]
... ... @@ -690,7 +690,6 @@
690 690  
691 691  * Each bits shows if the corresponding trigger has been configured.
692 692  
693 -
694 694  **Example:**
695 695  
696 696  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -702,7 +702,6 @@
702 702  
703 703  * Each bits shows which status has been trigger on this uplink.
704 704  
705 -
706 706  **Example:**
707 707  
708 708  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -714,7 +714,6 @@
714 714  
715 715  * Each bits shows which status has been trigger on this uplink.
716 716  
717 -
718 718  **Example:**
719 719  
720 720  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -754,8 +754,6 @@
754 754  
755 755  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
756 756  
757 -
758 -
759 759  === 3.4.1 Common Commands ===
760 760  
761 761  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -777,7 +777,6 @@
777 777  
778 778  **Example: **AT+TDC=30000. Means set interval to 30 seconds
779 779  
780 -
781 781  * Downlink Payload (prefix 0x01):
782 782  
783 783  (% class="box infomessage" %)
... ... @@ -800,7 +800,6 @@
800 800  
801 801  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
802 802  
803 -
804 804  * Downlink Payload (prefix 0x0A):
805 805  
806 806  (% class="box infomessage" %)
... ... @@ -816,7 +816,6 @@
816 816  
817 817  There is no AT Command to poll uplink
818 818  
819 -
820 820  * Downlink Payload (prefix 0x08):
821 821  
822 822  (% class="box infomessage" %)
... ... @@ -843,7 +843,6 @@
843 843  
844 844  0: Disable Trigger Mode
845 845  
846 -
847 847  * Downlink Payload (prefix 0x0A 06):
848 848  
849 849  (% class="box infomessage" %)
... ... @@ -861,7 +861,6 @@
861 861  
862 862  There is no AT Command for this feature.
863 863  
864 -
865 865  * Downlink Payload (prefix 0x AB 06):
866 866  
867 867  (% class="box infomessage" %)
... ... @@ -882,7 +882,6 @@
882 882  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
883 883  )))
884 884  
885 -
886 886  **Example:**
887 887  
888 888  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -911,12 +911,10 @@
911 911  
912 912  b : delay timing.
913 913  
914 -
915 915  **Example:**
916 916  
917 917  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
918 918  
919 -
920 920  * Downlink Payload (prefix 0x09 01 ):
921 921  
922 922  (% class="box infomessage" %)
... ... @@ -941,12 +941,10 @@
941 941  
942 942  b : delay timing.
943 943  
944 -
945 945  **Example:**
946 946  
947 947  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
948 948  
949 -
950 950  * Downlink Payload (prefix 0x09 02 ):
951 951  
952 952  (% class="box infomessage" %)
... ... @@ -967,7 +967,6 @@
967 967  **AT+ACLIM. **
968 968  )))
969 969  
970 -
971 971  * Downlink Payload (prefix 0xAA 01 ):
972 972  
973 973  (% class="box infomessage" %)
... ... @@ -988,7 +988,6 @@
988 988  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
989 989  )))
990 990  
991 -
992 992  * Downlink Payload (prefix 0xAA 00 ):
993 993  
994 994  (% class="box infomessage" %)
... ... @@ -1009,7 +1009,6 @@
1009 1009  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1010 1010  )))
1011 1011  
1012 -
1013 1013  * Downlink Payload (prefix 0xAC ):
1014 1014  
1015 1015  (% class="box infomessage" %)
... ... @@ -1025,7 +1025,6 @@
1025 1025  
1026 1026  There is no AT Command to control Digital Output
1027 1027  
1028 -
1029 1029  * Downlink Payload (prefix 0x02):
1030 1030  
1031 1031  (% class="box infomessage" %)
... ... @@ -1059,7 +1059,6 @@
1059 1059  
1060 1060  There is no AT Command to control Digital Output
1061 1061  
1062 -
1063 1063  * Downlink Payload (prefix 0xA9):
1064 1064  
1065 1065  (% class="box infomessage" %)
... ... @@ -1079,22 +1079,18 @@
1079 1079  
1080 1080  00: DO pins will change to an inverter state after timeout 
1081 1081  
1082 -
1083 1083  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1084 1084  
1085 1085  [[image:image-20220524093238-6.png]]
1086 1086  
1087 -
1088 1088  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1089 1089  
1090 1090  [[image:image-20220524093328-7.png]]
1091 1091  
1092 -
1093 1093  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1094 1094  
1095 1095  [[image:image-20220524093351-8.png]]
1096 1096  
1097 -
1098 1098  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1099 1099  
1100 1100   Latching time. Unit: ms
... ... @@ -1101,7 +1101,6 @@
1101 1101  
1102 1102  Device will upload a packet if downlink code executes successfully.
1103 1103  
1104 -
1105 1105  **Example payload:**
1106 1106  
1107 1107  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1122,13 +1122,12 @@
1122 1122  
1123 1123  
1124 1124  
1125 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1126 1126  
1127 1127  * AT Command:
1128 1128  
1129 1129  There is no AT Command to control Relay Output
1130 1130  
1131 -
1132 1132  * Downlink Payload (prefix 0x03):
1133 1133  
1134 1134  (% class="box infomessage" %)
... ... @@ -1158,7 +1158,6 @@
1158 1158  
1159 1159  There is no AT Command to control Relay Output
1160 1160  
1161 -
1162 1162  * Downlink Payload (prefix 0x05):
1163 1163  
1164 1164  (% class="box infomessage" %)
... ... @@ -1176,17 +1176,14 @@
1176 1176  
1177 1177  00: Relays will change to an inverter state after timeout
1178 1178  
1179 -
1180 1180  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1181 1181  
1182 1182  [[image:image-20220524093831-10.png]]
1183 1183  
1184 -
1185 1185  (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms
1186 1186  
1187 1187  Device will upload a packet if downlink code executes successfully.
1188 1188  
1189 -
1190 1190  **Example payload:**
1191 1191  
1192 1192  **~1. 05 01 11 07 D0**
... ... @@ -1218,7 +1218,6 @@
1218 1218  **AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1219 1219  )))
1220 1220  
1221 -
1222 1222  * Downlink Payload (prefix 0xA5):
1223 1223  
1224 1224  (% class="box infomessage" %)
... ... @@ -1245,7 +1245,6 @@
1245 1245  
1246 1246  Bb cc dd ee: number to be set
1247 1247  
1248 -
1249 1249  * Downlink Payload (prefix 0xA8):
1250 1250  
1251 1251  (% class="box infomessage" %)
... ... @@ -1298,6 +1298,7 @@
1298 1298  )))
1299 1299  
1300 1300  
1257 +
1301 1301  == 3.5 Integrate with Mydevice ==
1302 1302  
1303 1303  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0