From version < 77.8 >
edited by Xiaoling
on 2022/06/10 08:38
To version < 77.24 >
edited by Xiaoling
on 2022/06/10 08:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -273,6 +273,7 @@
273 273  [[image:1653298044601-602.png||height="405" width="709"]]
274 274  
275 275  
276 +
276 276  == 3.3 Uplink Payload ==
277 277  
278 278  There are five working modes + one interrupt mode on LT for different type application:
... ... @@ -284,6 +284,8 @@
284 284  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 285  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
286 286  
288 +
289 +
287 287  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
288 288  
289 289  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -319,6 +319,7 @@
319 319  * [1] RO1 relay channel is close and the RO1 LED is ON.
320 320  * [0] RO2 relay channel is open and RO2 LED is OFF;
321 321  
325 +
322 322  **LT22222-L:**
323 323  
324 324  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -334,6 +334,8 @@
334 334  ** DO1 is high in case there is load between DO1 and V+.
335 335  ** DO1 LED is off in both case
336 336  
341 +
342 +
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 339  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
... ... @@ -427,6 +427,7 @@
427 427  )))
428 428  
429 429  
436 +
430 430  === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI ===
431 431  
432 432  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -471,6 +471,8 @@
471 471  
472 472  )))
473 473  
481 +
482 +
474 474  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
475 475  
476 476  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -552,6 +552,7 @@
552 552  )))
553 553  
554 554  
564 +
555 555  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
556 556  
557 557  **LT22222-L**: This mode the DI1 is used as a counting pin.
... ... @@ -596,6 +596,8 @@
596 596  
597 597  )))
598 598  
609 +
610 +
599 599  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
600 600  
601 601  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
... ... @@ -719,6 +719,7 @@
719 719  When device got this command, it will send the MOD6 payload.
720 720  
721 721  
734 +
722 722  === 3.3.7 Payload Decoder ===
723 723  
724 724  (((
... ... @@ -727,6 +727,8 @@
727 727  
728 728  )))
729 729  
743 +
744 +
730 730  == 3.4 ​Configure LT via AT or Downlink ==
731 731  
732 732  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -739,11 +739,14 @@
739 739  
740 740  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
741 741  
757 +
758 +
742 742  === 3.4.1 Common Commands ===
743 743  
744 744  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
745 745  
746 746  
764 +
747 747  === 3.4.2 Sensor related commands ===
748 748  
749 749  ==== 3.4.2.1 Set Transmit Interval ====
... ... @@ -767,6 +767,7 @@
767 767  )))
768 768  
769 769  
788 +
770 770  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
771 771  
772 772  Set work mode.
... ... @@ -788,6 +788,7 @@
788 788  )))
789 789  
790 790  
810 +
791 791  ==== 3.4.2.3 Poll an uplink ====
792 792  
793 793  * AT Command:
... ... @@ -804,6 +804,7 @@
804 804  **Example**: 0x08FF, ask device to send an Uplink
805 805  
806 806  
827 +
807 807  ==== 3.4.2.4 Enable Trigger Mode ====
808 808  
809 809  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -827,6 +827,7 @@
827 827  )))
828 828  
829 829  
851 +
830 830  ==== 3.4.2.5 Poll trigger settings ====
831 831  
832 832  Poll trigger settings,
... ... @@ -843,6 +843,7 @@
843 843  )))
844 844  
845 845  
868 +
846 846  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
847 847  
848 848  Enable Disable DI1/DI2/DI2 as trigger,
... ... @@ -866,6 +866,7 @@
866 866  )))
867 867  
868 868  
892 +
869 869  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
870 870  
871 871  Set DI1 or DI3(for LT-33222-L) trigger.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0