Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -11,15 +11,12 @@ 11 11 12 12 13 13 14 - 15 - 16 - 17 17 = 1.Introduction = 18 18 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 -The Dragino (%style="color:blue" %)**LT series I/O Modules**(%%)are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (%style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %),**relay output**,**digital input**(%%)and(% style="color:blue" %)**digital output**(%%)etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.19 +The Dragino LT series I/O Modules are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as: analog current Input, analog voltage input, relay output, digital input and digital output etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 25 25 ((( ... ... @@ -27,7 +27,7 @@ 27 27 ))) 28 28 29 29 ((( 30 -The LT I/O Controllers is aiming to provide a n (%style="color:blue"%)**easy and low cost installation**(%%)by using LoRa wireless technology.27 +The LT I/O Controllers is aiming to provide a simple plug and play, low cost installation by using LoRaWAN wireless technology. 31 31 ))) 32 32 33 33 ((( ... ... @@ -51,8 +51,6 @@ 51 51 == 1.2 Specifications == 52 52 53 53 ((( 54 - 55 - 56 56 **Hardware System:** 57 57 ))) 58 58 ... ... @@ -75,7 +75,6 @@ 75 75 ))) 76 76 ))) 77 77 78 - 79 79 ((( 80 80 **Interface for Model: LT22222-L:** 81 81 ))) ... ... @@ -99,7 +99,6 @@ 99 99 Power Input 7~~ 24V DC. 100 100 ))) 101 101 102 - 103 103 ((( 104 104 **LoRa Spec:** 105 105 ))) ... ... @@ -164,8 +164,6 @@ 164 164 165 165 ))) 166 166 167 - 168 - 169 169 == 1.3 Features == 170 170 171 171 * LoRaWAN Class A & Class C protocol ... ... @@ -176,8 +176,6 @@ 176 176 * Firmware upgradable via program port 177 177 * Counting 178 178 179 - 180 - 181 181 == 1.4 Applications == 182 182 183 183 * Smart Buildings & Home Automation ... ... @@ -187,8 +187,6 @@ 187 187 * Smart Cities 188 188 * Smart Factory 189 189 190 - 191 - 192 192 == 1.5 Hardware Variants == 193 193 194 194 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -202,8 +202,6 @@ 202 202 * 1 x Counting Port 203 203 ))) 204 204 205 - 206 - 207 207 = 2. Power ON Device = 208 208 209 209 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -215,7 +215,6 @@ 215 215 [[image:1653297104069-180.png]] 216 216 217 217 218 - 219 219 = 3. Operation Mode = 220 220 221 221 == 3.1 How it works? == ... ... @@ -230,8 +230,6 @@ 230 230 231 231 ))) 232 232 233 - 234 - 235 235 == 3.2 Example to join LoRaWAN network == 236 236 237 237 ((( ... ... @@ -622,7 +622,6 @@ 622 622 623 623 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 624 624 625 - 626 626 (% style="color:#4f81bd" %)**Trigger base on current**: 627 627 628 628 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -631,7 +631,6 @@ 631 631 632 632 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 633 633 634 - 635 635 (% style="color:#4f81bd" %)**Trigger base on DI status**: 636 636 637 637 DI status trigger Flag. ... ... @@ -735,7 +735,7 @@ 735 735 There are two kinds of Commands: 736 736 ))) 737 737 738 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commandsand Downlink Command>>doc:Main.End.WebHome]]718 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands 739 739 740 740 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 741 ... ... @@ -806,7 +806,7 @@ 806 806 807 807 ==== 3.4.2.4 Enable Trigger Mode ==== 808 808 809 -Use of trigger mode, please check [[ADDMOD6>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]789 +Use of trigger mode, please check [[ADDMOD6>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 810 810 811 811 * AT Command: 812 812 ... ... @@ -922,7 +922,7 @@ 922 922 923 923 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 924 924 925 -Set current trigger , base on AC port. See [[trigger mode>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]905 +Set current trigger , base on AC port. See [[trigger mode>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 926 926 927 927 * AT Command: 928 928 ... ... @@ -935,19 +935,19 @@ 935 935 936 936 (% class="box infomessage" %) 937 937 ((( 938 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**918 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 939 939 ))) 940 940 941 941 942 942 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 943 943 944 -Set current trigger , base on AV port. See [[trigger mode>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]924 +Set current trigger , base on AV port. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] 945 945 946 946 * AT Command: 947 947 948 948 (% class="box infomessage" %) 949 949 ((( 950 -**AT+AVLIM. See [[trigger mode>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**930 +**AT+AVLIM. See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]]** 951 951 ))) 952 952 953 953 * Downlink Payload (prefix 0xAA 00 ): ... ... @@ -954,7 +954,7 @@ 954 954 955 955 (% class="box infomessage" %) 956 956 ((( 957 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>> ||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **937 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>url:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29]] ** 958 958 ))) 959 959 960 960 ... ... @@ -1151,13 +1151,13 @@ 1151 1151 1152 1152 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1153 1153 1154 -When voltage exceed the threshold, count. Feature see [[MOD4>> ||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1134 +When voltage exceed the threshold, count. Feature see [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]] 1155 1155 1156 1156 * AT Command: 1157 1157 1158 1158 (% class="box infomessage" %) 1159 1159 ((( 1160 -**AT+VOLMAX ~/~/ See [[MOD4>> ||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**1140 +**AT+VOLMAX ~/~/ See [[MOD4>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/#H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting]]** 1161 1161 ))) 1162 1162 1163 1163 * Downlink Payload (prefix 0xA5): ... ... @@ -1252,7 +1252,6 @@ 1252 1252 1253 1253 [[image:image-20220524094641-12.png||height="402" width="718"]] 1254 1254 1255 - 1256 1256 **Step 3**: Create an account or log in Mydevices. 1257 1257 1258 1258 **Step 4**: Search LT-22222-L(for both LT-22222-L / LT-33222-L) and add DevEUI.(% style="display:none" %) ... ... @@ -1299,103 +1299,50 @@ 1299 1299 [[image:1653357170703-587.png]] 1300 1300 1301 1301 ((( 1302 -((( 1303 1303 When use need to connect a device to the DI port, both DI1+ and DI1- must be connected. 1304 1304 ))) 1305 -))) 1306 1306 1307 -((( 1308 - 1309 -))) 1310 1310 1311 -((( 1312 1312 **Example1**: Connect to a Low active sensor. 1313 -))) 1314 1314 1315 -((( 1316 1316 This type of sensor will output a low signal GND when active. 1317 -))) 1318 1318 1319 -* ((( 1320 -Connect sensor’s output to DI1- 1321 -))) 1322 -* ((( 1323 -Connect sensor’s VCC to DI1+. 1324 -))) 1289 +* Connect sensor’s output to DI1- 1290 +* Connect sensor’s VCC to DI1+. 1325 1325 1326 -((( 1327 -So when sensor active, the current between NEC2501 pin1 and pin2 is: 1328 -))) 1292 +So when sensor active, the current between NEC2501 pin1 and pin2 is: 1329 1329 1330 -((( 1331 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1332 -))) 1294 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]] = DI1+ / 1K.** 1333 1333 1334 -((( 1335 -If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1336 -))) 1296 +If DI1+ = 12v, the //IF// = 12mA , So the LT-22222-L will be able to detect this active signal. 1337 1337 1338 -((( 1339 - 1340 -))) 1341 1341 1342 -((( 1343 1343 **Example2**: Connect to a High active sensor. 1344 -))) 1345 1345 1346 -((( 1347 1347 This type of sensor will output a high signal (example 24v) when active. 1348 -))) 1349 1349 1350 -* ((( 1351 -Connect sensor’s output to DI1+ 1352 -))) 1353 -* ((( 1354 -Connect sensor’s GND DI1-. 1355 -))) 1303 +* Connect sensor’s output to DI1+ 1304 +* Connect sensor’s GND DI1-. 1356 1356 1357 -((( 1358 1358 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1359 -))) 1360 1360 1361 -((( 1362 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1363 -))) 1308 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]** [[image:image-20220524095628-8.png]]= DI1+ / 1K.** 1364 1364 1365 -((( 1366 -If **DI1+ = 24v**, the[[image:1653968155772-850.png||height="23" width="19"]] 24mA , So the LT-22222-L will be able to detect this high active signal. 1367 -))) 1310 +If **DI1+ = 24v**, the [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]]** = 24mA , So the LT-22222-L will be able to detect this high active signal. 1368 1368 1369 -((( 1370 - 1371 -))) 1372 1372 1373 -((( 1374 1374 **Example3**: Connect to a 220v high active sensor. 1375 -))) 1376 1376 1377 -((( 1378 1378 Assume user want to monitor an active signal higher than 220v, to make sure not burn the photocoupler 1379 -))) 1380 1380 1381 -* ((( 1382 -Connect sensor’s output to DI1+ with a serial 50K resistor 1383 -))) 1384 -* ((( 1385 -Connect sensor’s GND DI1-. 1386 -))) 1317 +* Connect sensor’s output to DI1+ with a serial 50K resistor 1318 +* Connect sensor’s GND DI1-. 1387 1387 1388 -((( 1389 1389 So when sensor active, the current between NEC2501 pin1 and pin2 is: 1390 -))) 1391 1391 1392 -((( 1393 - [[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 51K.** 1394 -))) 1322 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]][[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LT-22222-L/WebHome/image-20220524095628-8.png?rev=1.1||alt="image-20220524095628-8.png"]]**[[image:image-20220524095628-8.png]] = DI1+ / 51K.** 1395 1395 1396 -((( 1397 -If sensor output is 220v, the [[image:1653968155772-850.png||height="23" width="19"]](% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1398 -))) 1324 +If sensor output is 220v, the (% id="cke_bm_243359S" style="display:none" %)[[image:image-20220524095628-8.png]](%%) = DI1+ / 51K. = 4.3mA , So the LT-22222-L will be able to detect this high active signal safely. 1399 1399 1400 1400 1401 1401 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === ... ... @@ -1876,11 +1876,6 @@ 1876 1876 ((( 1877 1877 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn’t support AT+DEBUG. User can update to latest firmware first. 1878 1878 1879 - 1880 -== 5.5 Can i use point to point communication for LT-22222-L? == 1881 - 1882 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1883 - 1884 1884 1885 1885 ))) 1886 1886 ... ... @@ -1895,8 +1895,10 @@ 1895 1895 ))) 1896 1896 1897 1897 ((( 1898 -Please see this link for how to debug: [[LoRaWAN Communication Debug>> doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H5.1Howitwork"]]1819 +Please see this link for how to debug: [[LoRaWAN Communication Debug>>LoRaWAN Communication Debug||anchor="H5.1Howitwork"]] 1899 1899 1821 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H5.1Howitwork]] 1822 + 1900 1900 1901 1901 ))) 1902 1902 ... ... @@ -1905,7 +1905,9 @@ 1905 1905 ))) 1906 1906 1907 1907 ((( 1908 -See this link for trouble shooting: [[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 1831 +See this link for trouble shooting: 1832 + 1833 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/>>http://wiki1.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/]] 1909 1909 ))) 1910 1910 1911 1911 ((( ... ... @@ -1917,7 +1917,9 @@ 1917 1917 ))) 1918 1918 1919 1919 ((( 1920 -It might be about the channels mapping. [[Please see this link for detail>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1845 +It might be about the channels mapping. Please see this link for detail: 1846 + 1847 +[[http:~~/~~/wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband>>http://wiki1.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H2.NoticeofUS9152FCN4702FAU915Frequencyband]] 1921 1921 ))) 1922 1922 1923 1923 (((
- 1653968155772-850.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- 1653968164738-884.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- 1653968172068-832.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -886 bytes - Content
- image-20220531113415-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -172 bytes - Content