Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -467,6 +467,7 @@ 467 467 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 459 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 466 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 482 + 483 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -495,25 +495,20 @@ 495 495 ((( 496 496 ((( 497 497 **AT+MOD=4** 498 -))) 499 -))) 500 500 501 -(% class="box infomessage" %) 502 -((( 503 -((( 504 504 **ATZ** 505 505 ))) 506 506 ))) 507 507 508 -((( 509 - 510 -))) 511 511 497 + 512 512 ((( 513 513 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 514 514 ))) 515 515 516 516 ((( 503 + 504 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -520,35 +520,20 @@ 520 520 (% class="box infomessage" %) 521 521 ((( 522 522 ((( 523 -**AT+SETCNT=3,60 (set AVI Count to 60)** 524 -))) 525 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 526 526 527 -(% class="box infomessage" %) 528 -((( 529 -((( 530 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 531 -))) 532 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 533 533 534 -(% class="box infomessage" %) 535 -((( 536 -((( 537 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 538 -))) 539 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 540 540 541 -(% class="box infomessage" %) 542 -((( 543 -((( 544 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 545 545 ))) 546 546 ))) 547 547 548 548 549 - 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 524 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] ... ... @@ -579,12 +579,7 @@ 579 579 ((( 580 580 ((( 581 581 **AT+MOD=5** 582 -))) 583 -))) 584 584 585 -(% class="box infomessage" %) 586 -((( 587 -((( 588 588 **ATZ** 589 589 ))) 590 590 ))) ... ... @@ -597,6 +597,7 @@ 597 597 598 598 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 599 599 568 + 600 600 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 601 601 602 602 For example, if user has configured below commands: ... ... @@ -604,15 +604,13 @@ 604 604 * **AT+MOD=1 ** **~-~->** The normal working mode 605 605 * **AT+ADDMOD6=1** **~-~->** Enable trigger 606 606 607 - 608 608 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 609 609 610 610 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 611 611 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 612 612 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 613 613 614 -**AT Command to set Trigger Condition**: 615 - 616 616 (% style="color:#4f81bd" %)**Trigger base on voltage**: 617 617 618 618 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -624,6 +624,7 @@ 624 624 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 625 625 626 626 594 + 627 627 (% style="color:#4f81bd" %)**Trigger base on current**: 628 628 629 629 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -633,6 +633,7 @@ 633 633 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 634 634 635 635 604 + 636 636 (% style="color:#4f81bd" %)**Trigger base on DI status**: 637 637 638 638 DI status trigger Flag. ... ... @@ -639,12 +639,13 @@ 639 639 640 640 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 641 641 611 + 642 642 **Example:** 643 643 644 644 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 645 645 646 646 647 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 648 648 649 649 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 650 650 ... ... @@ -673,6 +673,7 @@ 673 673 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 674 674 675 675 646 + 676 676 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 677 677 678 678 MOD6 Payload : total 11 bytes payload ... ... @@ -686,7 +686,6 @@ 686 686 687 687 * Each bits shows if the corresponding trigger has been configured. 688 688 689 - 690 690 **Example:** 691 691 692 692 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -698,7 +698,6 @@ 698 698 699 699 * Each bits shows which status has been trigger on this uplink. 700 700 701 - 702 702 **Example:** 703 703 704 704 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -710,7 +710,6 @@ 710 710 711 711 * Each bits shows which status has been trigger on this uplink. 712 712 713 - 714 714 **Example:** 715 715 716 716 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -731,6 +731,8 @@ 731 731 === 3.3.7 Payload Decoder === 732 732 733 733 ((( 702 + 703 + 734 734 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 735 735 736 736 ... ... @@ -737,7 +737,6 @@ 737 737 ))) 738 738 739 739 740 - 741 741 == 3.4 Configure LT via AT or Downlink == 742 742 743 743 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -764,7 +764,7 @@ 764 764 765 765 Set device uplink interval. 766 766 767 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 768 768 769 769 (% class="box infomessage" %) 770 770 ((( ... ... @@ -774,7 +774,7 @@ 774 774 **Example: **AT+TDC=30000. Means set interval to 30 seconds 775 775 776 776 777 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 778 778 779 779 (% class="box infomessage" %) 780 780 ((( ... ... @@ -787,7 +787,7 @@ 787 787 788 788 Set work mode. 789 789 790 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 791 791 792 792 (% class="box infomessage" %) 793 793 ((( ... ... @@ -797,7 +797,7 @@ 797 797 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 798 798 799 799 800 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 801 801 802 802 (% class="box infomessage" %) 803 803 ((( ... ... @@ -808,12 +808,12 @@ 808 808 809 809 ==== 3.4.2.3 Poll an uplink ==== 810 810 811 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 812 812 813 813 There is no AT Command to poll uplink 814 814 815 815 816 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 817 817 818 818 (% class="box infomessage" %) 819 819 ((( ... ... @@ -828,7 +828,7 @@ 828 828 829 829 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 830 830 831 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 832 832 833 833 (% class="box infomessage" %) 834 834 ((( ... ... @@ -840,7 +840,7 @@ 840 840 0: Disable Trigger Mode 841 841 842 842 843 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 844 844 845 845 (% class="box infomessage" %) 846 846 ((( ... ... @@ -853,12 +853,12 @@ 853 853 854 854 Poll trigger settings, 855 855 856 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 857 857 858 858 There is no AT Command for this feature. 859 859 860 860 861 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 862 862 863 863 (% class="box infomessage" %) 864 864 ((( ... ... @@ -871,7 +871,7 @@ 871 871 872 872 Enable Disable DI1/DI2/DI2 as trigger, 873 873 874 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 875 875 876 876 (% class="box infomessage" %) 877 877 ((( ... ... @@ -883,7 +883,7 @@ 883 883 884 884 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 885 885 886 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 887 887 888 888 (% class="box infomessage" %) 889 889 ((( ... ... @@ -896,7 +896,7 @@ 896 896 897 897 Set DI1 or DI3(for LT-33222-L) trigger. 898 898 899 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 900 900 901 901 (% class="box infomessage" %) 902 902 ((( ... ... @@ -913,7 +913,7 @@ 913 913 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 914 914 915 915 916 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 917 917 918 918 (% class="box infomessage" %) 919 919 ((( ... ... @@ -926,7 +926,7 @@ 926 926 927 927 Set DI2 trigger. 928 928 929 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 930 930 931 931 (% class="box infomessage" %) 932 932 ((( ... ... @@ -943,7 +943,7 @@ 943 943 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 944 944 945 945 946 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 947 947 948 948 (% class="box infomessage" %) 949 949 ((( ... ... @@ -956,7 +956,7 @@ 956 956 957 957 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 958 958 959 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 960 960 961 961 (% class="box infomessage" %) 962 962 ((( ... ... @@ -964,7 +964,7 @@ 964 964 ))) 965 965 966 966 967 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 968 968 969 969 (% class="box infomessage" %) 970 970 ((( ... ... @@ -977,7 +977,7 @@ 977 977 978 978 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 979 979 980 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 981 981 982 982 (% class="box infomessage" %) 983 983 ((( ... ... @@ -985,7 +985,7 @@ 985 985 ))) 986 986 987 987 988 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 989 989 990 990 (% class="box infomessage" %) 991 991 ((( ... ... @@ -998,7 +998,7 @@ 998 998 999 999 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1000 1000 1001 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1002 1002 1003 1003 (% class="box infomessage" %) 1004 1004 ((( ... ... @@ -1006,7 +1006,7 @@ 1006 1006 ))) 1007 1007 1008 1008 1009 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1010 1010 1011 1011 (% class="box infomessage" %) 1012 1012 ((( ... ... @@ -1017,12 +1017,12 @@ 1017 1017 1018 1018 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1019 1019 1020 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1021 1021 1022 1022 There is no AT Command to control Digital Output 1023 1023 1024 1024 1025 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1026 1026 1027 1027 (% class="box infomessage" %) 1028 1028 ((( ... ... @@ -1051,12 +1051,12 @@ 1051 1051 1052 1052 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1053 1053 1054 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1055 1055 1056 1056 There is no AT Command to control Digital Output 1057 1057 1058 1058 1059 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1060 1060 1061 1061 (% class="box infomessage" %) 1062 1062 ((( ... ... @@ -1120,12 +1120,12 @@ 1120 1120 1121 1121 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1122 1122 1123 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1124 1124 1125 1125 There is no AT Command to control Relay Output 1126 1126 1127 1127 1128 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1129 1129 1130 1130 (% class="box infomessage" %) 1131 1131 ((( ... ... @@ -1150,18 +1150,16 @@ 1150 1150 1151 1151 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1152 1152 1153 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1154 1154 1155 1155 There is no AT Command to control Relay Output 1156 1156 1157 1157 1158 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1159 1159 1160 -(% class="box infomessage" %) 1161 -((( 1162 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1163 -))) 1129 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1164 1164 1131 + 1165 1165 This is to control the relay output time of relay. Include four bytes: 1166 1166 1167 1167 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1203,35 +1203,28 @@ 1203 1203 1204 1204 1205 1205 1173 + 1206 1206 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1207 1207 1208 1208 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1209 1209 1210 -* AT Command: 1178 +* (% style="color:#037691" %)**AT Command:** 1211 1211 1212 -(% class="box infomessage" %) 1213 -((( 1214 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1215 -))) 1180 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1216 1216 1217 1217 1218 -* Downlink Payload (prefix 0xA5): 1183 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1219 1219 1220 -(% class="box infomessage" %) 1221 -((( 1222 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1223 -))) 1185 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1224 1224 1225 1225 1226 1226 1189 + 1227 1227 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1228 1228 1229 -* AT Command: 1192 +* (% style="color:#037691" %)**AT Command:** 1230 1230 1231 -(% class="box infomessage" %) 1232 -((( 1233 -**AT+SETCNT=aa,(bb cc dd ee) ** 1234 -))) 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1235 1235 1236 1236 aa: 1: Set count1, 1237 1237 ... ... @@ -1242,51 +1242,40 @@ 1242 1242 Bb cc dd ee: number to be set 1243 1243 1244 1244 1245 -* Downlink Payload (prefix 0xA8): 1205 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1246 1246 1247 -(% class="box infomessage" %) 1248 -((( 1249 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1250 -))) 1207 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1251 1251 1252 1252 1253 1253 1211 + 1254 1254 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1255 1255 1256 1256 Clear counting for counting mode 1257 1257 1258 -* AT Command: 1216 +* (% style="color:#037691" %)**AT Command:** 1259 1259 1260 -(% class="box infomessage" %) 1261 -((( 1262 -**AT+CLRCOUNT ~/~/ clear all counting** 1263 -))) 1218 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1264 1264 1265 -* Downlink Payload (prefix 0xA6): 1266 1266 1267 -(% class="box infomessage" %) 1268 -((( 1269 -**0x A6 01 ~/~/ clear all counting,** 1270 -))) 1221 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1271 1271 1223 +**0x A6 01 ** ~/~/ clear all counting 1272 1272 1273 1273 1226 + 1227 + 1274 1274 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1275 1275 1276 -* AT Command: 1230 +* (% style="color:#037691" %)**AT Command:** 1277 1277 1278 -(% class="box infomessage" %) 1279 -((( 1280 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1281 -))) 1232 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1282 1282 1283 -* Downlink Payload (prefix 0xA7): 1284 1284 1285 -(% class="box infomessage" %) 1286 -((( 1287 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1288 -))) 1235 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1289 1289 1237 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1238 + 1290 1290 ((( 1291 1291 range: aa bb cc:0 to 16777215, (unit:second) 1292 1292 ... ... @@ -1294,6 +1294,7 @@ 1294 1294 ))) 1295 1295 1296 1296 1246 + 1297 1297 == 3.5 Integrate with Mydevice == 1298 1298 1299 1299 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1983,8 +1983,16 @@ 1983 1983 ))) 1984 1984 1985 1985 ((( 1986 - 1936 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1987 1987 1938 +If the device is not shut down, but directly powered off. 1939 + 1940 +It will default that this is a power-off state. 1941 + 1942 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1943 + 1944 +After restart, the status before power failure will be read from flash. 1945 + 1988 1988 = 6. Trouble Shooting = 1989 1989 ))) 1990 1990