... ... @@ -310,6 +310,7 @@
310 310  * [1] RO1 relay channel is close and the RO1 LED is ON.
311 311  * [0] RO2 relay channel is open and RO2 LED is OFF;
312 312  
313 +
313 313  **LT22222-L:**
314 314  
315 315  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -325,8 +325,11 @@
325 325  ** DO1 is high in case there is load between DO1 and V+.
326 326  ** DO1 LED is off in both case
327 327  
329 +
330 +
328 328  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
329 329  
333 +
330 330  **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins.
331 331  
332 332  (((
... ... @@ -335,6 +335,7 @@
335 335  
336 336  [[image:image-20220523180452-3.png]]
337 337  
342 +
338 338  (((
339 339  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below
340 340  )))
... ... @@ -350,6 +350,8 @@
350 350  )))
351 351  
352 352  (((
358 +
359 +
353 353  **To use counting mode, please run:**
354 354  )))
355 355  
... ... @@ -368,6 +368,8 @@
368 368  )))
369 369  
370 370  (((
378 +
379 +
371 371  (% style="color:#4f81bd" %)**AT Commands for counting:**
372 372  )))
373 373  
... ... @@ -464,9 +464,9 @@
464 464  )))
465 465  
466 466  
467 -
468 468  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
469 469  
478 +
470 470  **LT22222-L**: This mode the DI1 is used as a counting pin.
471 471  
472 472  The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour.
... ... @@ -473,6 +473,7 @@
473 473  
474 474  [[image:image-20220523181903-8.png]]
475 475  
485 +
476 476  (((
477 477  (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
478 478  )))
... ... @@ -488,6 +488,8 @@
488 488  )))
489 489  
490 490  (((
501 +
502 +
491 491  **To use this mode, please run:**
492 492  )))
493 493  
... ... @@ -514,6 +514,8 @@
514 514  )))
515 515  
516 516  (((
529 +
530 +
517 517  **Plus below command for AVI1 Counting:**
518 518  )))
519 519  
... ... @@ -549,6 +549,7 @@
549 549  
550 550  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
551 551  
566 +
552 552  **LT22222-L**: This mode the DI1 is used as a counting pin.
553 553  
554 554  [[image:image-20220523182334-9.png]]
... ... @@ -597,6 +597,7 @@
597 597  
598 598  === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) ===
599 599  
615 +
600 600  (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.**
601 601  
602 602  For example, if user has configured below commands:
... ... @@ -604,13 +604,11 @@
604 604  * **AT+MOD=1 ** **~-~->** The normal working mode
605 605  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
606 606  
607 -
608 608  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
609 609  
610 610  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
611 611  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
612 612  
613 -
614 614  **AT Command to set Trigger Condition**:
615 615  
616 616  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -686,7 +686,6 @@
686 686  
687 687  * Each bits shows if the corresponding trigger has been configured.
688 688  
689 -
690 690  **Example:**
691 691  
692 692  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -698,7 +698,6 @@
698 698  
699 699  * Each bits shows which status has been trigger on this uplink.
700 700  
701 -
702 702  **Example:**
703 703  
704 704  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -710,7 +710,6 @@
710 710  
711 711  * Each bits shows which status has been trigger on this uplink.
712 712  
713 -
714 714  **Example:**
715 715  
716 716  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -731,6 +731,8 @@
731 731  === 3.3.7 Payload Decoder ===
732 732  
733 733  (((
745 +
746 +
734 734  **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]]
735 735  
736 736  
... ... @@ -751,7 +751,6 @@
751 751  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
752 752  
753 753  
754 -
755 755  === 3.4.1 Common Commands ===
756 756  
757 757  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]