Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,6 +19,8 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 + 23 + 22 22 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 23 23 ))) 24 24 ... ... @@ -48,6 +48,7 @@ 48 48 49 49 ))) 50 50 53 + 51 51 == 1.2 Specifications == 52 52 53 53 ((( ... ... @@ -76,6 +76,8 @@ 76 76 ))) 77 77 78 78 ((( 82 + 83 + 79 79 **Interface for Model: LT22222-L:** 80 80 ))) 81 81 ... ... @@ -99,6 +99,8 @@ 99 99 ))) 100 100 101 101 ((( 107 + 108 + 102 102 **LoRa Spec:** 103 103 ))) 104 104 ... ... @@ -159,6 +159,8 @@ 159 159 * ((( 160 160 Packet engine up to 256 bytes with CRC. 161 161 169 + 170 + 162 162 163 163 ))) 164 164 ... ... @@ -172,6 +172,8 @@ 172 172 * Firmware upgradable via program port 173 173 * Counting 174 174 184 + 185 + 175 175 == 1.4 Applications == 176 176 177 177 * Smart Buildings & Home Automation ... ... @@ -181,6 +181,8 @@ 181 181 * Smart Cities 182 182 * Smart Factory 183 183 195 + 196 + 184 184 == 1.5 Hardware Variants == 185 185 186 186 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -194,6 +194,7 @@ 194 194 * 1 x Counting Port 195 195 ))) 196 196 210 + 197 197 = 2. Power ON Device = 198 198 199 199 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -216,12 +216,9 @@ 216 216 217 217 ((( 218 218 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 - 220 - 221 221 ))) 222 222 223 223 224 - 225 225 == 3.2 Example to join LoRaWAN network == 226 226 227 227 ((( ... ... @@ -230,12 +230,13 @@ 230 230 231 231 [[image:image-20220523172350-1.png||height="266" width="864"]] 232 232 244 + 233 233 ((( 234 234 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 235 235 ))) 236 236 237 237 ((( 238 -**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 250 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller. 239 239 ))) 240 240 241 241 ((( ... ... @@ -244,6 +244,7 @@ 244 244 245 245 [[image:1653297924498-393.png]] 246 246 259 + 247 247 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 248 248 249 249 Add APP EUI in the application. ... ... @@ -257,7 +257,7 @@ 257 257 258 258 259 259 ((( 260 -**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 273 +(% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 261 261 ))) 262 262 263 263 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -275,6 +275,8 @@ 275 275 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 276 276 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 277 291 + 292 + 278 278 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 279 279 280 280 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -282,6 +282,8 @@ 282 282 [[image:image-20220523174024-3.png]] 283 283 284 284 ((( 300 + 301 + 285 285 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 286 286 ))) 287 287 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 For example if payload is: [[image:image-20220523175847-2.png]] 297 297 315 + 298 298 **The value for the interface is: ** 299 299 300 300 AVI1 channel voltage is 0x04AB/1000=1195(DEC)/1000=1.195V ... ... @@ -325,8 +325,11 @@ 325 325 ** DO1 is high in case there is load between DO1 and V+. 326 326 ** DO1 LED is off in both case 327 327 346 + 347 + 328 328 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 329 329 350 + 330 330 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 331 331 332 332 ((( ... ... @@ -335,6 +335,7 @@ 335 335 336 336 [[image:image-20220523180452-3.png]] 337 337 359 + 338 338 ((( 339 339 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DO3, DO2 and DO1. Totally 1bytes as below 340 340 ))) ... ... @@ -350,6 +350,8 @@ 350 350 ))) 351 351 352 352 ((( 375 + 376 + 353 353 **To use counting mode, please run:** 354 354 ))) 355 355 ... ... @@ -357,17 +357,14 @@ 357 357 ((( 358 358 ((( 359 359 **AT+MOD=2** 360 -))) 361 -))) 362 362 363 -(% class="box infomessage" %) 364 -((( 365 -((( 366 366 **ATZ** 367 367 ))) 368 368 ))) 369 369 370 370 ((( 390 + 391 + 371 371 (% style="color:#4f81bd" %)**AT Commands for counting:** 372 372 ))) 373 373 ... ... @@ -379,40 +379,15 @@ 379 379 ((( 380 380 ((( 381 381 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 382 -))) 383 -))) 384 384 385 -(% class="box infomessage" %) 386 -((( 387 -((( 388 388 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 389 -))) 390 -))) 391 391 392 -(% class="box infomessage" %) 393 -((( 394 -((( 395 395 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 -))) 397 -))) 398 398 399 -(% class="box infomessage" %) 400 -((( 401 -((( 402 402 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 403 -))) 404 -))) 405 405 406 -(% class="box infomessage" %) 407 -((( 408 -((( 409 409 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 410 -))) 411 -))) 412 412 413 -(% class="box infomessage" %) 414 -((( 415 -((( 416 416 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 417 417 ))) 418 418 ))) ... ... @@ -447,12 +447,7 @@ 447 447 ((( 448 448 ((( 449 449 **AT+MOD=3** 450 -))) 451 -))) 452 452 453 -(% class="box infomessage" %) 454 -((( 455 -((( 456 456 **ATZ** 457 457 ))) 458 458 ))) ... ... @@ -459,8 +459,6 @@ 459 459 460 460 ((( 461 461 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 462 - 463 - 464 464 ))) 465 465 466 466 ... ... @@ -467,6 +467,7 @@ 467 467 468 468 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 469 469 459 + 470 470 **LT22222-L**: This mode the DI1 is used as a counting pin. 471 471 472 472 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. ... ... @@ -473,6 +473,7 @@ 473 473 474 474 [[image:image-20220523181903-8.png]] 475 475 466 + 476 476 ((( 477 477 (% style="color:#4f81bd" %)**DIDORO **(%%)is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 478 478 ))) ... ... @@ -488,6 +488,8 @@ 488 488 ))) 489 489 490 490 ((( 482 + 483 + 491 491 **To use this mode, please run:** 492 492 ))) 493 493 ... ... @@ -495,25 +495,20 @@ 495 495 ((( 496 496 ((( 497 497 **AT+MOD=4** 498 -))) 499 -))) 500 500 501 -(% class="box infomessage" %) 502 -((( 503 -((( 504 504 **ATZ** 505 505 ))) 506 506 ))) 507 507 508 -((( 509 - 510 -))) 511 511 497 + 512 512 ((( 513 513 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 514 514 ))) 515 515 516 516 ((( 503 + 504 + 517 517 **Plus below command for AVI1 Counting:** 518 518 ))) 519 519 ... ... @@ -520,40 +520,27 @@ 520 520 (% class="box infomessage" %) 521 521 ((( 522 522 ((( 523 -**AT+SETCNT=3,60 (set AVI Count to 60)** 524 -))) 525 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 526 526 527 -(% class="box infomessage" %) 528 -((( 529 -((( 530 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 531 -))) 532 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 533 533 534 -(% class="box infomessage" %) 535 -((( 536 -((( 537 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 538 -))) 539 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 540 540 541 -(% class="box infomessage" %) 542 -((( 543 -((( 544 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 545 545 ))) 546 546 ))) 547 547 548 548 549 - 550 550 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 551 551 524 + 552 552 **LT22222-L**: This mode the DI1 is used as a counting pin. 553 553 554 554 [[image:image-20220523182334-9.png]] 555 555 556 556 ((( 530 + 531 + 557 557 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 558 558 ))) 559 559 ... ... @@ -568,6 +568,8 @@ 568 568 ))) 569 569 570 570 ((( 546 + 547 + 571 571 **To use this mode, please run:** 572 572 ))) 573 573 ... ... @@ -575,12 +575,7 @@ 575 575 ((( 576 576 ((( 577 577 **AT+MOD=5** 578 -))) 579 -))) 580 580 581 -(% class="box infomessage" %) 582 -((( 583 -((( 584 584 **ATZ** 585 585 ))) 586 586 ))) ... ... @@ -587,8 +587,6 @@ 587 587 588 588 ((( 589 589 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 590 - 591 - 592 592 ))) 593 593 594 594 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 597 597 568 + 598 598 (% style="color:#4f81bd" %)**This mode is an optional mode for trigger purpose. It can run together with other mode.** 599 599 600 600 For example, if user has configured below commands: ... ... @@ -602,15 +602,13 @@ 602 602 * **AT+MOD=1 ** **~-~->** The normal working mode 603 603 * **AT+ADDMOD6=1** **~-~->** Enable trigger 604 604 605 - 606 606 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 607 607 608 608 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 609 609 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 610 610 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 611 611 612 -**AT Command to set Trigger Condition**: 613 - 614 614 (% style="color:#4f81bd" %)**Trigger base on voltage**: 615 615 616 616 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -622,6 +622,7 @@ 622 622 AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 623 623 624 624 594 + 625 625 (% style="color:#4f81bd" %)**Trigger base on current**: 626 626 627 627 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> ... ... @@ -631,6 +631,7 @@ 631 631 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) 632 632 633 633 604 + 634 634 (% style="color:#4f81bd" %)**Trigger base on DI status**: 635 635 636 636 DI status trigger Flag. ... ... @@ -637,12 +637,13 @@ 637 637 638 638 Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG > 639 639 611 + 640 640 **Example:** 641 641 642 642 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 643 643 644 644 645 -**Downlink Command to set Trigger Condition** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 646 646 647 647 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 648 648 ... ... @@ -671,6 +671,7 @@ 671 671 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 672 672 673 673 646 + 674 674 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 675 675 676 676 MOD6 Payload : total 11 bytes payload ... ... @@ -684,7 +684,6 @@ 684 684 685 685 * Each bits shows if the corresponding trigger has been configured. 686 686 687 - 688 688 **Example:** 689 689 690 690 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -696,7 +696,6 @@ 696 696 697 697 * Each bits shows which status has been trigger on this uplink. 698 698 699 - 700 700 **Example:** 701 701 702 702 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -708,7 +708,6 @@ 708 708 709 709 * Each bits shows which status has been trigger on this uplink. 710 710 711 - 712 712 **Example:** 713 713 714 714 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -729,6 +729,8 @@ 729 729 === 3.3.7 Payload Decoder === 730 730 731 731 ((( 702 + 703 + 732 732 **Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 733 733 734 734 ... ... @@ -735,7 +735,6 @@ 735 735 ))) 736 736 737 737 738 - 739 739 == 3.4 Configure LT via AT or Downlink == 740 740 741 741 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -762,7 +762,7 @@ 762 762 763 763 Set device uplink interval. 764 764 765 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 766 766 767 767 (% class="box infomessage" %) 768 768 ((( ... ... @@ -772,7 +772,7 @@ 772 772 **Example: **AT+TDC=30000. Means set interval to 30 seconds 773 773 774 774 775 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 776 776 777 777 (% class="box infomessage" %) 778 778 ((( ... ... @@ -785,7 +785,7 @@ 785 785 786 786 Set work mode. 787 787 788 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 789 789 790 790 (% class="box infomessage" %) 791 791 ((( ... ... @@ -795,7 +795,7 @@ 795 795 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 796 796 797 797 798 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 799 799 800 800 (% class="box infomessage" %) 801 801 ((( ... ... @@ -806,12 +806,12 @@ 806 806 807 807 ==== 3.4.2.3 Poll an uplink ==== 808 808 809 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 810 810 811 811 There is no AT Command to poll uplink 812 812 813 813 814 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 815 815 816 816 (% class="box infomessage" %) 817 817 ((( ... ... @@ -826,7 +826,7 @@ 826 826 827 827 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 828 828 829 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 830 830 831 831 (% class="box infomessage" %) 832 832 ((( ... ... @@ -838,7 +838,7 @@ 838 838 0: Disable Trigger Mode 839 839 840 840 841 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 842 842 843 843 (% class="box infomessage" %) 844 844 ((( ... ... @@ -851,12 +851,12 @@ 851 851 852 852 Poll trigger settings, 853 853 854 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 855 855 856 856 There is no AT Command for this feature. 857 857 858 858 859 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 860 860 861 861 (% class="box infomessage" %) 862 862 ((( ... ... @@ -869,7 +869,7 @@ 869 869 870 870 Enable Disable DI1/DI2/DI2 as trigger, 871 871 872 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 873 873 874 874 (% class="box infomessage" %) 875 875 ((( ... ... @@ -881,7 +881,7 @@ 881 881 882 882 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 883 883 884 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 885 885 886 886 (% class="box infomessage" %) 887 887 ((( ... ... @@ -894,7 +894,7 @@ 894 894 895 895 Set DI1 or DI3(for LT-33222-L) trigger. 896 896 897 -* AT Command: 868 +* (% style="color:#037691" %)AT Command: 898 898 899 899 (% class="box infomessage" %) 900 900 ((( ... ... @@ -911,7 +911,7 @@ 911 911 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 912 912 913 913 914 -* Downlink Payload (prefix 0x09 01 ): 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 915 915 916 916 (% class="box infomessage" %) 917 917 ((( ... ... @@ -924,7 +924,7 @@ 924 924 925 925 Set DI2 trigger. 926 926 927 -* AT Command: 898 +* (% style="color:#037691" %)AT Command: 928 928 929 929 (% class="box infomessage" %) 930 930 ((( ... ... @@ -941,7 +941,7 @@ 941 941 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 942 942 943 943 944 -* Downlink Payload (prefix 0x09 02 ): 915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 945 945 946 946 (% class="box infomessage" %) 947 947 ((( ... ... @@ -954,7 +954,7 @@ 954 954 955 955 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 956 956 957 -* AT Command: 928 +* (% style="color:#037691" %)AT Command: 958 958 959 959 (% class="box infomessage" %) 960 960 ((( ... ... @@ -962,7 +962,7 @@ 962 962 ))) 963 963 964 964 965 -* Downlink Payload (prefix 0xAA 01 ): 936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 966 966 967 967 (% class="box infomessage" %) 968 968 ((( ... ... @@ -975,7 +975,7 @@ 975 975 976 976 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 977 977 978 -* AT Command: 949 +* (% style="color:#037691" %)AT Command: 979 979 980 980 (% class="box infomessage" %) 981 981 ((( ... ... @@ -983,7 +983,7 @@ 983 983 ))) 984 984 985 985 986 -* Downlink Payload (prefix 0xAA 00 ): 957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 987 987 988 988 (% class="box infomessage" %) 989 989 ((( ... ... @@ -996,7 +996,7 @@ 996 996 997 997 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 998 998 999 -* AT Command: 970 +* (% style="color:#037691" %)AT Command: 1000 1000 1001 1001 (% class="box infomessage" %) 1002 1002 ((( ... ... @@ -1004,7 +1004,7 @@ 1004 1004 ))) 1005 1005 1006 1006 1007 -* Downlink Payload (prefix 0xAC ): 978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 1008 1008 1009 1009 (% class="box infomessage" %) 1010 1010 ((( ... ... @@ -1015,12 +1015,12 @@ 1015 1015 1016 1016 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1017 1017 1018 -* AT Command: 989 +* (% style="color:#037691" %)AT Command: 1019 1019 1020 1020 There is no AT Command to control Digital Output 1021 1021 1022 1022 1023 -* Downlink Payload (prefix 0x02): 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 1024 1024 1025 1025 (% class="box infomessage" %) 1026 1026 ((( ... ... @@ -1049,12 +1049,12 @@ 1049 1049 1050 1050 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1051 1051 1052 -* AT Command: 1023 +* (% style="color:#037691" %)AT Command: 1053 1053 1054 1054 There is no AT Command to control Digital Output 1055 1055 1056 1056 1057 -* Downlink Payload (prefix 0xA9): 1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 1058 1058 1059 1059 (% class="box infomessage" %) 1060 1060 ((( ... ... @@ -1118,12 +1118,12 @@ 1118 1118 1119 1119 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1120 1120 1121 -* AT Command: 1092 +* (% style="color:#037691" %)AT Command: 1122 1122 1123 1123 There is no AT Command to control Relay Output 1124 1124 1125 1125 1126 -* Downlink Payload (prefix 0x03): 1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1127 1127 1128 1128 (% class="box infomessage" %) 1129 1129 ((( ... ... @@ -1148,18 +1148,16 @@ 1148 1148 1149 1149 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1150 1150 1151 -* AT Command: 1122 +* (% style="color:#037691" %)AT Command: 1152 1152 1153 1153 There is no AT Command to control Relay Output 1154 1154 1155 1155 1156 -* Downlink Payload (prefix 0x05): 1127 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1157 1157 1158 -(% class="box infomessage" %) 1159 -((( 1160 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1161 -))) 1129 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1162 1162 1131 + 1163 1163 This is to control the relay output time of relay. Include four bytes: 1164 1164 1165 1165 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1201,35 +1201,28 @@ 1201 1201 1202 1202 1203 1203 1173 + 1204 1204 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1205 1205 1206 1206 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1207 1207 1208 -* AT Command: 1178 +* (% style="color:#037691" %)**AT Command:** 1209 1209 1210 -(% class="box infomessage" %) 1211 -((( 1212 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1213 -))) 1180 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1214 1214 1215 1215 1216 -* Downlink Payload (prefix 0xA5): 1183 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1217 1217 1218 -(% class="box infomessage" %) 1219 -((( 1220 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1221 -))) 1185 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1222 1222 1223 1223 1224 1224 1189 + 1225 1225 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1226 1226 1227 -* AT Command: 1192 +* (% style="color:#037691" %)**AT Command:** 1228 1228 1229 -(% class="box infomessage" %) 1230 -((( 1231 -**AT+SETCNT=aa,(bb cc dd ee) ** 1232 -))) 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1233 1233 1234 1234 aa: 1: Set count1, 1235 1235 ... ... @@ -1240,51 +1240,40 @@ 1240 1240 Bb cc dd ee: number to be set 1241 1241 1242 1242 1243 -* Downlink Payload (prefix 0xA8): 1205 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1244 1244 1245 -(% class="box infomessage" %) 1246 -((( 1247 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1248 -))) 1207 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1249 1249 1250 1250 1251 1251 1211 + 1252 1252 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1253 1253 1254 1254 Clear counting for counting mode 1255 1255 1256 -* AT Command: 1216 +* (% style="color:#037691" %)**AT Command:** 1257 1257 1258 -(% class="box infomessage" %) 1259 -((( 1260 -**AT+CLRCOUNT ~/~/ clear all counting** 1261 -))) 1218 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1262 1262 1263 -* Downlink Payload (prefix 0xA6): 1264 1264 1265 -(% class="box infomessage" %) 1266 -((( 1267 -**0x A6 01 ~/~/ clear all counting,** 1268 -))) 1221 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1269 1269 1223 +**0x A6 01 ** ~/~/ clear all counting 1270 1270 1271 1271 1226 + 1227 + 1272 1272 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1273 1273 1274 -* AT Command: 1230 +* (% style="color:#037691" %)**AT Command:** 1275 1275 1276 -(% class="box infomessage" %) 1277 -((( 1278 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1279 -))) 1232 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1280 1280 1281 -* Downlink Payload (prefix 0xA7): 1282 1282 1283 -(% class="box infomessage" %) 1284 -((( 1285 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1286 -))) 1235 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1287 1287 1237 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1238 + 1288 1288 ((( 1289 1289 range: aa bb cc:0 to 16777215, (unit:second) 1290 1290 ... ... @@ -1292,6 +1292,7 @@ 1292 1292 ))) 1293 1293 1294 1294 1246 + 1295 1295 == 3.5 Integrate with Mydevice == 1296 1296 1297 1297 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1981,8 +1981,16 @@ 1981 1981 ))) 1982 1982 1983 1983 ((( 1984 - 1936 +== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1985 1985 1938 +If the device is not shut down, but directly powered off. 1939 + 1940 +It will default that this is a power-off state. 1941 + 1942 +In modes 2 to 5, DO RO status and pulse count are saved in flash. 1943 + 1944 +After restart, the status before power failure will be read from flash. 1945 + 1986 1986 = 6. Trouble Shooting = 1987 1987 ))) 1988 1988