Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -602,13 +602,11 @@ 602 602 * **AT+MOD=1 ** **~-~->** The normal working mode 603 603 * **AT+ADDMOD6=1** **~-~->** Enable trigger 604 604 605 - 606 606 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 607 607 608 608 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 609 609 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 610 610 611 - 612 612 **AT Command to set Trigger Condition**: 613 613 614 614 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -660,17 +660,14 @@ 660 660 661 661 Yy4 yy4: AC2 or AV2 high limit. 662 662 663 - 664 664 **Example1**: AA 00 13 88 00 00 00 00 00 00 665 665 666 666 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 667 667 668 - 669 669 **Example2**: AA 02 01 00 670 670 671 671 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 672 672 673 - 674 674 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 675 675 676 676 MOD6 Payload : total 11 bytes payload ... ... @@ -677,7 +677,6 @@ 677 677 678 678 [[image:image-20220524085923-1.png]] 679 679 680 - 681 681 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 682 682 683 683 [[image:image-20220524090106-2.png]] ... ... @@ -684,7 +684,6 @@ 684 684 685 685 * Each bits shows if the corresponding trigger has been configured. 686 686 687 - 688 688 **Example:** 689 689 690 690 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -696,7 +696,6 @@ 696 696 697 697 * Each bits shows which status has been trigger on this uplink. 698 698 699 - 700 700 **Example:** 701 701 702 702 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -708,7 +708,6 @@ 708 708 709 709 * Each bits shows which status has been trigger on this uplink. 710 710 711 - 712 712 **Example:** 713 713 714 714 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -747,9 +747,8 @@ 747 747 * (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 748 748 749 749 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 741 +* 750 750 751 - 752 - 753 753 === 3.4.1 Common Commands === 754 754 755 755 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1116,7 +1116,7 @@ 1116 1116 1117 1117 1118 1118 1119 -=== =3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====1109 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1120 1120 1121 1121 * AT Command: 1122 1122