... ... @@ -602,13 +602,11 @@
602 602  * **AT+MOD=1 ** **~-~->** The normal working mode
603 603  * **AT+ADDMOD6=1**   **~-~->** Enable trigger
604 604  
605 -
606 606  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
607 607  
608 608  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
609 609  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
610 610  
611 -
612 612  **AT Command to set Trigger Condition**:
613 613  
614 614  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -660,17 +660,14 @@
660 660  
661 661   Yy4 yy4: AC2 or AV2 high limit.
662 662  
663 -
664 664  **Example1**: AA 00 13 88 00 00 00 00 00 00
665 665  
666 666  Same as AT+AVLIM=5000,0,0,0   (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore)
667 667  
668 -
669 669  **Example2**: AA 02 01 00
670 670  
671 671  Same as AT+ DTRI =1,0  (Enable DI1 trigger / disable DI2 trigger)
672 672  
673 -
674 674  (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:**
675 675  
676 676  MOD6 Payload : total 11 bytes payload
... ... @@ -677,7 +677,6 @@
677 677  
678 678  [[image:image-20220524085923-1.png]]
679 679  
680 -
681 681  (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below
682 682  
683 683  [[image:image-20220524090106-2.png]]
... ... @@ -684,7 +684,6 @@
684 684  
685 685  * Each bits shows if the corresponding trigger has been configured.
686 686  
687 -
688 688  **Example:**
689 689  
690 690  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -696,7 +696,6 @@
696 696  
697 697  * Each bits shows which status has been trigger on this uplink.
698 698  
699 -
700 700  **Example:**
701 701  
702 702  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -708,7 +708,6 @@
708 708  
709 709  * Each bits shows which status has been trigger on this uplink.
710 710  
711 -
712 712  **Example:**
713 713  
714 714  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -748,8 +748,6 @@
748 748  
749 749  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
750 750  
751 -
752 -
753 753  === 3.4.1 Common Commands ===
754 754  
755 755  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -771,7 +771,6 @@
771 771  
772 772  **Example: **AT+TDC=30000. Means set interval to 30 seconds
773 773  
774 -
775 775  * Downlink Payload (prefix 0x01):
776 776  
777 777  (% class="box infomessage" %)
... ... @@ -794,7 +794,6 @@
794 794  
795 795  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
796 796  
797 -
798 798  * Downlink Payload (prefix 0x0A):
799 799  
800 800  (% class="box infomessage" %)
... ... @@ -810,7 +810,6 @@
810 810  
811 811  There is no AT Command to poll uplink
812 812  
813 -
814 814  * Downlink Payload (prefix 0x08):
815 815  
816 816  (% class="box infomessage" %)
... ... @@ -837,7 +837,6 @@
837 837  
838 838  0: Disable Trigger Mode
839 839  
840 -
841 841  * Downlink Payload (prefix 0x0A 06):
842 842  
843 843  (% class="box infomessage" %)
... ... @@ -855,7 +855,6 @@
855 855  
856 856  There is no AT Command for this feature.
857 857  
858 -
859 859  * Downlink Payload (prefix 0x AB 06):
860 860  
861 861  (% class="box infomessage" %)
... ... @@ -876,7 +876,6 @@
876 876  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
877 877  )))
878 878  
879 -
880 880  **Example:**
881 881  
882 882  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
... ... @@ -905,12 +905,10 @@
905 905  
906 906  b : delay timing.
907 907  
908 -
909 909  **Example:**
910 910  
911 911  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
912 912  
913 -
914 914  * Downlink Payload (prefix 0x09 01 ):
915 915  
916 916  (% class="box infomessage" %)
... ... @@ -935,12 +935,10 @@
935 935  
936 936  b : delay timing.
937 937  
938 -
939 939  **Example:**
940 940  
941 941  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
942 942  
943 -
944 944  * Downlink Payload (prefix 0x09 02 ):
945 945  
946 946  (% class="box infomessage" %)
... ... @@ -961,7 +961,6 @@
961 961  **AT+ACLIM. **
962 962  )))
963 963  
964 -
965 965  * Downlink Payload (prefix 0xAA 01 ):
966 966  
967 967  (% class="box infomessage" %)
... ... @@ -982,7 +982,6 @@
982 982  **AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
983 983  )))
984 984  
985 -
986 986  * Downlink Payload (prefix 0xAA 00 ):
987 987  
988 988  (% class="box infomessage" %)
... ... @@ -1003,7 +1003,6 @@
1003 1003  **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
1004 1004  )))
1005 1005  
1006 -
1007 1007  * Downlink Payload (prefix 0xAC ):
1008 1008  
1009 1009  (% class="box infomessage" %)
... ... @@ -1019,7 +1019,6 @@
1019 1019  
1020 1020  There is no AT Command to control Digital Output
1021 1021  
1022 -
1023 1023  * Downlink Payload (prefix 0x02):
1024 1024  
1025 1025  (% class="box infomessage" %)
... ... @@ -1053,7 +1053,6 @@
1053 1053  
1054 1054  There is no AT Command to control Digital Output
1055 1055  
1056 -
1057 1057  * Downlink Payload (prefix 0xA9):
1058 1058  
1059 1059  (% class="box infomessage" %)
... ... @@ -1073,22 +1073,18 @@
1073 1073  
1074 1074  00: DO pins will change to an inverter state after timeout 
1075 1075  
1076 -
1077 1077  (% style="color:#4f81bd" %)**Third Byte**(%%): Control Method and Ports status:
1078 1078  
1079 1079  [[image:image-20220524093238-6.png]]
1080 1080  
1081 -
1082 1082  (% style="color:#4f81bd" %)**Fourth Byte**(%%): Control Method and Ports status:
1083 1083  
1084 1084  [[image:image-20220524093328-7.png]]
1085 1085  
1086 -
1087 1087  (% style="color:#4f81bd" %)**Fifth Byte**(%%): Control Method and Ports status:
1088 1088  
1089 1089  [[image:image-20220524093351-8.png]]
1090 1090  
1091 -
1092 1092  (% style="color:#4f81bd" %)**Sixth and Seventh Byte**:
1093 1093  
1094 1094   Latching time. Unit: ms
... ... @@ -1095,7 +1095,6 @@
1095 1095  
1096 1096  Device will upload a packet if downlink code executes successfully.
1097 1097  
1098 -
1099 1099  **Example payload:**
1100 1100  
1101 1101  **~1. A9 01 01 01 01 07 D0**
... ... @@ -1116,13 +1116,12 @@
1116 1116  
1117 1117  
1118 1118  
1119 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1088 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ===
1120 1120  
1121 1121  * AT Command:
1122 1122  
1123 1123  There is no AT Command to control Relay Output
1124 1124  
1125 -
1126 1126  * Downlink Payload (prefix 0x03):
1127 1127  
1128 1128  (% class="box infomessage" %)