Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -607,7 +607,6 @@ 607 607 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 608 608 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 609 609 610 - 611 611 **AT Command to set Trigger Condition**: 612 612 613 613 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -659,17 +659,14 @@ 659 659 660 660 Yy4 yy4: AC2 or AV2 high limit. 661 661 662 - 663 663 **Example1**: AA 00 13 88 00 00 00 00 00 00 664 664 665 665 Same as AT+AVLIM=5000,0,0,0 (If AVI1 voltage lower than 5V , trigger uplink, 0 means ignore) 666 666 667 - 668 668 **Example2**: AA 02 01 00 669 669 670 670 Same as AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 671 671 672 - 673 673 (% style="color:#4f81bd" %)**Trigger Settings Payload Explanation:** 674 674 675 675 MOD6 Payload : total 11 bytes payload ... ... @@ -676,7 +676,6 @@ 676 676 677 677 [[image:image-20220524085923-1.png]] 678 678 679 - 680 680 (% style="color:#4f81bd" %)**TRI FLAG1**(%%) is a combination to show if trigger is set for this part. Totally 1byte as below 681 681 682 682 [[image:image-20220524090106-2.png]] ... ... @@ -683,7 +683,6 @@ 683 683 684 684 * Each bits shows if the corresponding trigger has been configured. 685 685 686 - 687 687 **Example:** 688 688 689 689 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -695,7 +695,6 @@ 695 695 696 696 * Each bits shows which status has been trigger on this uplink. 697 697 698 - 699 699 **Example:** 700 700 701 701 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -707,7 +707,6 @@ 707 707 708 708 * Each bits shows which status has been trigger on this uplink. 709 709 710 - 711 711 **Example:** 712 712 713 713 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -748,7 +748,6 @@ 748 748 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 749 749 750 750 751 - 752 752 === 3.4.1 Common Commands === 753 753 754 754 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1115,7 +1115,7 @@ 1115 1115 1116 1116 1117 1117 1118 -=== =3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====1109 +=== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 === 1119 1119 1120 1120 * AT Command: 1121 1121